• Title/Summary/Keyword: energy-density

Search Result 5,707, Processing Time 0.032 seconds

Study on nutrition, dietary and health status of middle-aged Korean men according to sedentary hours: based on the 2019 Korea National Health and Nutrition Examination Survey (중장년 한국 남성의 좌식 시간에 따른 영양, 식이 및 건강행태 연구: 국민건강영양조사 제8기 1차년도(2019년) 자료를 이용하여)

  • Jeong, Dajeong;Lee, Jeehyun;Yoon, Eunju
    • Journal of Nutrition and Health
    • /
    • v.55 no.3
    • /
    • pp.359-375
    • /
    • 2022
  • Purpose: Adult Korean men belonging to the main economically active population are known to have long sedentary hours. This study was undertaken to determine the difference and relevance of sedentary hours on the nutrition, diet, and health status of adult men, and to suggest how to prevent health risk factors. Methods: Subjects (n = 1,068) were classified into 4 groups based on their sedentary hours, ranging from the first quartile (Q1) having the least hours spent sitting, to the fourth quartile (Q4) spending the longest hours. Results: Subjects belonging to Q4 had the lowest average age, the largest waist circumference, and the highest level of education. Among those engaged in economic activities, the ratio of white-collar workers was significantly higher in Q4. Accordingly, the rate of not doing high-intensity or moderate-intensity physical activity while working was also the highest in Q4. A significant difference was obtained in the drinking frequency between groups, but this was found to be associated with the average working hours rather than sedentary hours. The proportion of not doing aerobic exercise was higher with longer sitting hours. The highest diagnosis of diabetes (8.8%) was obtained in the Q4 group. Among the factors related to cardiovascular disease, only low density lipoprotein-cholesterol showed a significant difference, with Q4 being significantly higher than Q1. Considering energy and nutrient intake, vitamin B1 and calcium intake were the lowest in the group with the longest sitting hours, as well as the least consumption of vitamin C than the recommended estimated average requirement. Conclusion: The results of this study suggest that the health and nutritional status of Korean adult men are affected by sedentary hours. This should be recognized as a health risk factor and guidelines need to be developed for sedentary lifestyle management.

Optimization of Characteristic Change due to Differences in the Electrode Mixing Method (전극 혼합 방식의 차이로 인한 특성 변화 최적화)

  • Jeong-Tae Kim;Carlos Tafara Mpupuni;Beom-Hui Lee;Sun-Yul Ryou
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • The cathode, which is one of the four major components of a lithium secondary battery, is an important component responsible for the energy density of the battery. The mixing process of active material, conductive material, and polymer binder is very essential in the commonly used wet manufacturing process of the cathode. However, in the case of mixing conditions of the cathode, since there is no systematic method, in most cases, differences in performance occur depending on the manufacturer. Therefore, LiMn2O4 (LMO) cathodes were prepared using a commonly used THINKY mixer and homogenizer to optimize the mixing method in the cathode slurry preparation step, and their characteristics were compared. Each mixing condition was performed at 2000 RPM and 7 min, and to determine only the difference in the mixing method during the manufacture of the cathode other experiment conditions (mixing time, material input order, etc.) were kept constant. Among the manufactured THINKY mixer LMO (TLMO) and homogenizer LMO (HLMO), HLMO has more uniform particle dispersion than TLMO, and thus shows higher adhesive strength. Also, the result of the electrochemical evaluation reveals that HLMO cathode showed improved performance with a more stable life cycle compared to TLMO. The initial discharge capacity retention rate of HLMO at 69 cycles was 88%, which is about 4.4 times higher than that of TLMO, and in the case of rate capability, HLMO exhibited a better capacity retention even at high C-rates of 10, 15, and 20 C and the capacity recovery at 1 C was higher than that of TLMO. It's postulated that the use of a homogenizer improves the characteristics of the slurry containing the active material, the conductive material, and the polymer binder creating an electrically conductive network formed by uniformly dispersing the conductive material suppressing its strong electrostatic properties thus avoiding aggregation. As a result, surface contact between the active material and the conductive material increases, electrons move more smoothly, changes in lattice volume during charging and discharging are more reversible and contact resistance between the active material and the conductive material is suppressed.

Ecotoxicity of Daphnia magna and Aliivibrio fischeri on Potentially Harmful Substances Emissionsfrom Battery Manufacturing Processes: Lithium, Nickel, and Sulfate (배터리 제조공정에서 배출되는 잠재 유해 물질에 대한 물벼룩과 발광박테리아의 생태독성: 리튬, 니켈, 황산염을 대상으로)

  • Inhye Roh;Kijune Sung
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.2
    • /
    • pp.123-133
    • /
    • 2023
  • Wastewater generated in the secondary battery production process contains lithium and high-concentration sulfate. Recently, as demand as demand for high-Ni precursors with high-energy density has surged, nickel emission is also a concern. Lithium and sulfate are not included in the current water pollutant discharge standard, so if they are not properly processed and discharged, the negative effect on future environment may be great. Therefore, in this study, the ecotoxicity of lithium, nickel, and sulfate, which are potential contaminants that can be discharged from the secondary battery production process, was evaluated using water flea (Daphnia magna) and luminescent bacteria (Aliivibrio fischeri). As a result of the ecotoxicity test, 24-hour and 48-hour D. magna EC50 values of lithium were 18.2mg/L and 14.5mg/L, nickel EC50 values were 7.2mg/L and 5.4mg/L, and sulfate EC50 values were 4,605.5mg/L and 4,345.0mg/L, respectively. In the case of D. magna, it was found that there was a difference in ecotoxicity according to the contaminants and exposure time (24 hours, 48 hours). Comparing the EC50 of D. magna for lithium, nickel, and sulfate, the EC50 of nickel at 24h and 48h was 39.6-37.2% compared to lithium and 0.1-0.2% compared to sulfate, which was the most toxic among the three substances. The difference appeared to be at a similarlevelregardless of the exposure time. The EC50 of sulfate was 253.0-299.7% and 639.5-804.6%, respectively, compared to lithium and nickel, showing the least toxicity among the three substances. The 30-minute EC50 values of luminescent bacteria forlithium, nickel, and sulfate were 2,755.8mg/L, 7.4mg/L, and 66,047.3mg/L,respectively. Unlike nickel, it was confirmed that there was a difference in sensitivity between D. magna and A. fischeri bacteria to lithium and sulfate. Studies on the mixture toxicity of these substances are needed.

Metal Oxides Decorated Carbon Nanotube Freestanding Electrodes for High Performance of Lithium-sulfur Batteries (고성능 리튬-황 전지를 위한 금속산화물을 첨가한 탄소나노튜브 프리스탠딩 전극)

  • Yun Jung Shin;Hyeon Seo Jeong;Eun Mi Kim;Tae Yun Kim;Sang Mun Jeong
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.426-438
    • /
    • 2023
  • Lithium-sulfur batteries, recently attracting attention as next-generation batteries, have high energy density but are limited in application due to sulfur's insulating properties, shuttle phenomenon, and volume expansion. This study used an economical and simple vacuum filtration method to prepare a freestanding electrode without a binder and collector. Carbon nanotubes (CNTs) are used to improve the electrical conductivity of sulfur, where CNT also acts as both collector and conductor. In addition, metal oxides (MOx, M=Ni, Mg), which are easy to adsorb lithium polysulfide, are added to the CNT/S electrode to suppress the shuttle reaction in lithium-sulfur batteries, which is a result of suppressing the loss of active sulfur material due to the excellent adsorption of lithium polysulfide by metal oxides. The MOx@CNT/S electrode exhibited higher capacity characteristics and cycle stability than the CNT/S electrode without metal oxides. Among the MOx@CNT/S electrodes, the NiO@CNT/S electrode displayed a high discharge capacity of 780 mAh g-1 at 1 C and an extreme capacity decrease to 134 mAh g-1 after 200 cycles. Although the MgO@CNT/S electrode exhibited a low discharge rate of 544 mAh g-1 in the initial cycle, it showed good cycle stability with 90% of capacity retention up to 200 cycles. Further, to achieve high capacity and cycle stability, the Ni0.7Mg0.3O@CNT/S electrode, mixed with Ni:Mg in the ratio of 0.7:0.3, manifested an initial discharge rate of 755 mAh g-1 (1 C) and a capacity retention rate of more than 90% after 200 cycles. Therefore, applying binary metal oxides to CNT/S provides a freestanding electrode for developing economical and high-performance Li-S batteries, effectively improving lithium polysulfide's high capacity characteristics and dissolution.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Effect of Geijibokryunghwan and each constituent herb on inhibition of platelet aggregation (계지복령환(桂枝茯笭丸) 및 그 구성약물(構成藥物)의 혈소판응집억제(血小板凝集抑制)에 관(關)한 연구(硏究))

  • Kim, Jong-Goo;Park, Sun-Dong;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-129
    • /
    • 2000
  • The cause that the increase of animality fat intakes, under exercise, fatness, adding the stress, advanced age etc., the occurrence rate of the circulation system disease has been increased. And the thrombosis importantly came to the front as the risk factor of these circulation system's disease. Nowadays, the ischemic disease has especially discussed, for example the angina or myocardial infarction, originated in thrombosis that came from the platelet aggregation. In the western medicine, as the cure and prevention, using the aspirin or ticlopidine for platelet aggregation suppressant. But in the , the curing method must be used properly according to the pectoralgia or heartache's kind, state, grade. The platelet do not attache to the normal hemangioendothelial cell. But when it stimulated by endothelium peronia and so on, it attache to the injury endothelium or rise aggregation between the platelet. On this time, it secrete the platelet aggregation inducer as like ADP, thromboxane A2 from the inside of platelet. So it has first defensive function through the aggregation augment that prevent the celerity consumption of blood. But the activation of abnormal platelet occur the platelet grume and thrombogenesis. So it bring up the occlusive angiosis, so to speak, cardiovascular disease, cerebrovascular disease, arterial sclerosis. In oriental medicine, the thrombosis in the category of blood stasis and this blood stasis present the generalise or local blood circulation disturbance that generated by all kinds of pathological fact or blood stream retention accompanying with a series of syndrome. As the syndrome, stabbing pain fixed at certain region, squamous and dry skin, fullness and pain of the chest and hypochondrium, firmness and fullness of the lower abdomen, black stool, dark purple tongue or with ecchymoses and petechiae etc.. has been created. And it becomes the pathopoiesis cause that the convulsion and palpitation, severe palpitatiion, tympanites, the symtom complex with a mass or swelling in the abdomen, insanity, stricken by wind etc.. Moreover, it used the drugs for invigorating blood circulation and eliminating blood stasis or drugs for removing blood stasis for all kinds of syndrome through the blood stasis. And the drugs for activating the blood circulation, such as Salviae Radix, Angelicae Sinensis Radix, Persicae Semen, Achyranthis Radix, Cnidii Rhizoma, Carthami Flos are used for that. And it is used to the herbs of insects that has strong effect about the disintergrating blood stasis such as Hirudo, Scolopendrae Corpus, Buthus, Lumbricus etc.. On this study, It used Geijibokryunghwan(GBH) and the consisting herbs to investigate the influence of platelet aggregation about drugs that used to improvement various symptoms created by the thrombosis in oriental medicine. GBH formula has as formula recorded in the , action of 'eleminating the evil and not impairment of healthy energy' and 'promoting the flow of QI and cold and heat, so used for the expel blood stasis herbs from the ancient. Therefore we investigated the restraint effect of GBH and the consisting herbs about the platelet agregation induced to the ADP, AA or collagen. The conclusion is following. 1. When it added the aggregation inducer after that it added GBH and individual consisting herbs in the PRP, GBH showed the (+) inhibition effect on the platelet aggregation and it showed the (+) inhibition effect in the individual consisting herbs as like Paeoniae Radix and Moutan Cortex Radicis. 2. It showed the (+), (+,++) inhibition effect on the platelet aggregation in Paeoniae Radix Hoelen, Paeoniae Radix Moutan Cortex Radicis, Hoelen Moutan Cortex Radicis etc. 3. In the aggregation inhibition activating on the difference of density, GBH showed strong inhibition effect to the aggregation state induced to collagen, and it showed the inhibition effect in the individual consisting herbs as like Paeoniae Radix and Moutan Cortex Radicis about the aggregation induced by the collagen. 4. It showed the strong inhibition effect about the aggregation induced by the collagen in Paeoniae Radix Hoelen, Paeoniae Radix Moutan Cortex Radicis, Hoelen Moutan Cortex Radicis etc Like this, as confirm GBH and the individual consisting herb's inhibition effect of platelet aggregation, We considerated that GBH and the individual consisting herbs have practical applicational value of clinical trial in the thrombosis caused by platelet aggregation.

  • PDF