• 제목/요약/키워드: energy saving control

검색결과 701건 처리시간 0.025초

부분축열식 빙축열시스템의 냉방에너지소비 절약을 위한 냉동기 On-Off 제어기법의 평가 (Evaluation of Chiller On-Off Control of Partial Ice Storage System for Energy Saving in Cooling Operation)

  • 이경호;최병윤;이상렬;한승호
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2000
  • This paper describes an operation strategy of ice storage systems for energy saving during building cooling. In this study, chiller is assumed not having function of part load control. Thus, it is needed to adopt on-off control with the objective function of summed energy consumption for minimum energy consumption. A conventional control strategy compared with the chiller-on-off control is chiller-priority control. in this control chiller operates as its full capacity and ice storage meets the rest of the cooling load.

  • PDF

소규모 사무공간의 조명에너지 절감율 평가에 관한 연구 (Evaluation of Lighting Energy Saving Rate in a Small Office Space)

  • 김한용;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.50-58
    • /
    • 2012
  • The objective of this study is to evaluate the lighting dimming rates with various parameters of the building skin in a small office. We compared to simulated workplane illuminance and measured workplane illuminance for the base model. After that, the five veriables(the presence of vertical wall in double skin facade, the presence of windowsill, window to wall ratio(WWR), window visible transmittance, the width of double skin facade) were applied to base model, and we analyzed the simulated lighting energy saving rates. The results are listed as below. The simulated workplane illuminance results are similar to the measurement. Simulated illuminance was smaller than measured illuminance by 16.5%(60 lx). In accordance with applicable building skin parameters, lighting energy saving rate results are summarized as follows. Lighting energy saving rate of case1(windowsill height 0.7m) is higher than that of base case(windowsill and vertical wall) by 7.3% and the lighting energy saving rate of case2(no vertical wall) is higher than that of base case by 7.6% and the lighting energy saving rate of case3(no windowsill and vertical wall) is higher than that of base case by 12.4%. The lighting energy saving rate is increased by 2.3%, when window visible transmittance is increased from 70% to 86%. The lighting energy saving rate is increased by 4.6%, when we changed the WWR 70% to 90%. lighting energy savings rate is increased by 6.5%, when the width of double skin facade is reduced from 1m to 0.3m.

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구 (A study on the saving of energy consumption load using electrical heat control system)

  • 한규일
    • 수산해양기술연구
    • /
    • 제49권1호
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

유압 트랜스포머를 이용한 유압 실린더의 에너지 절감에 관한 연구 (A Study on Energy Saving Hydraulic Cylinder System Using Hydraulic Transformer)

  • 이민수;조용래;윤홍수;안경관
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.49-56
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is a combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. In this paper the effect of transformer is studied. Multiple closed loop controllers with displacement feedback of variable pump/motor, speed feedback and position feedback of cylinder are used. The efficiency and energy consumption when cylinder is driven up and down is calculated by simulation. Simulation results show that considerable energy saving is achieved by choosing load ratio, circuit type and supply pressure.

정보통신 기기의 Energy 절감을 위한 동향분석 및 새로운 관리표준 수립 (Development of new control standards and Investigation of current status of World wide Energy saving about IT products)

  • 양재혁;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.320-323
    • /
    • 2011
  • 전세계적으로 Issue가 되고 있는 친환경 관련 에너지 절감에 대한 국내외 표준화 동향을 중장기적으로 IT제품위주로 분석한다. 그리고 국내외 기준에 부합할 수 있는 새로운 관리표준 개발에 기여하고자 새로운 기준을 제시한다. 그리하여 새로운 무역장벽으로 부상하고 있는 에너지 절감규제에 선대응하여 IT 업계 및 부품업계의 새로운 지침을 제공하여 친환경 정책에 부합하고자 한다.

  • PDF

초고층 건물 커미셔닝에 따른 에너지 절감 효과 예측 (Prediction of Energy Saving Effects by Commissioning of High-Rise Building)

  • 조현;김효준;류성룡;조영흠
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2018
  • In this study, the energy commissioning was conducted for high-rise buildings(manual control). First of all, we conducted monitoring the energy use of buildings (electricity, heating, etc.), a commissioning improvement (automatic control) was proposed for each system. In addition, energy simulation was conducted to predict the effectiveness of the reform measures. As a result, terminal units control the greatest energy saving effect, If we applied all the improvements, we could save about 20% less than traditional energy usage, and it turned out that $CO_2$ emissions were reduced by about 19% when converted to $CO_2$.

빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발 (Development of control and monitoring board for building energy saving valve)

  • 오진석;강영민;장재희
    • 한국정보통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.895-902
    • /
    • 2018
  • 건물에 의한 에너지 소비량은 미국 및 일본 등 선진국에서는 전체 국가 에너지 소비량의 40%에 육박하고 있으며, 우리나라에서도 전체 에너지 소비량의 24%를 차지하고 있는 것으로 보고되고 있다. 빌딩에서 HVAC (Heating, Ventilation, and Air conditioning)은 필요 열량에 따라 냉각 유량을 자유롭게 제어할 수 없기 때문에 에너지가 효율적으로 사용되지 않고 있다. 따라서 에너지 절감 밸브를 사용함으로써 유량을 필요한 열량만큼 제어하여 에너지를 절감할 수 있다. 본 논문에서는 에너지 절감 밸브를 개발하기 위한 기본적인 상태를 정의하고 저전력, 고 가성비의 PIC 프로세서 기반의 빌딩 에너지 절감 밸브용 제어 및 감시 보드를 개발한다. 설계된 보드는 온도차 측정을 위한 2개의 온도 값과 유량 값 및 계산된 열량에 관한 정보를 실시간으로 디스플레이 및 전송한다. 개발된 제어 감시 보드는 향후 밸브의 상태를 실시간으로 파악하거나 해상용 밸브 등을 개발하는 데 유용하게 사용될 것이다.

작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발 (Development of Hybrid Excavator for Regeneration of Boom Potential Energy)

  • 윤종일;안경관;딩광졍;강종민;김재홍
    • 유공압시스템학회논문집
    • /
    • 제6권4호
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF

조명제어시스템을 위한 효율적인 계측 및 검증(M&V) 기법 연구 (A Study on the Effective M&V Method for the Lighting Control System)

  • 김정욱;부창진;김정혁;오성보;김호찬
    • 에너지공학
    • /
    • 제20권3호
    • /
    • pp.216-223
    • /
    • 2011
  • 본 논문에서는 다양한 공장과 빌딩에서 조명제어시스템을 대상으로 계측 및 검증(M&V) 방법을 사용하여 효율적인 에너지 절약 방법을 제시한다. 에너지 가격을 줄이기 위해서는 전력피크시간에 제어가능한 다양한 수요자원을 고려하는 필요하지만, 일반적으로 빌딩에서 고려되는 수요자원은 피크전력이다. 본 논문에서는 M&V 방법을 사용하여 전력소비량을 줄일 수 있는 새로운 에너지절약방법을 제안하고 현장계측시스템을 구성하고 시뮬레이션 방법을 통해 제안된 방법이 효과적임을 확인한다.