• Title/Summary/Keyword: energy regulation

Search Result 889, Processing Time 0.027 seconds

Feasibility Study for Application of Frequency Regulation ESS in Cuba: Technological Effects on Improving Frequency Compensation (쿠바 주파수조정 ESS 운영 전략 검토: 주파수 보상 효과 분석)

  • Kim, Soo-Yeol;Lee, Seong-eun;Kim, Jin-tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.123-127
    • /
    • 2020
  • KEPCO has installed Frequency Regulation ESS (FR ESS) of 376 MW since 2015. Frequency Regulation is ancillary service to support stabilizing system frequency, which is divided into governor free and automatic generation control. KEPCO operates FR ESS as governor free application and leads FR ESS market with capability of diverse demonstration and operation experiences. To expand FR ESS role during transient states of power system, KEPCO has extended operating time of charging and discharging. KEPCO has also changed speed droop lower than before to improve contribution on frequency compensation, and acquired much experiences of differentiating bad cells from others. Based on these technologies and know-hows, KEPCO Research Institutes received request of feasibility study and technical cooperation for overseas FR ESS business. This paper suggests the simple and practical method for making technological feasibility study of FR ESS.

Regulation of Systemic Energy Homeostasis by Peripheral Serotonin

  • Namkung, Jun;Oh, Chang-Myung;Park, Sangkyu;Kim, Hail
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.2 no.2
    • /
    • pp.43-45
    • /
    • 2016
  • Whole body energy balance is achieved through the coordinated regulation of energy intake and energy expenditure in various tissues including liver, muscle and adipose tissues. A positive energy imbalance by excessive energy intake or insufficient energy expenditure results in obesity and related metabolic diseases. Although there have been many obesity treatment trials aimed at the reduction of energy intake, these strategies have achieved only limited success because of their associated adverse effects. Serotonin is among those traditional pharmacological targets for anti-obesity treatment because central 5-HT functions as an anorexigenic neurotransmitter in the brain. Thus, there have been many trials aimed at increasing the activity of 5-HT in the central nervous system, and some of the developed methods are already used in the clinical setting as anti-obesity drugs. However, recent studies suggest the new functions of peripheral serotonin in energy homeostasis ranging from the endocrine regulation by gut-derived serotonin to the autocrine/paracrine regulation by adipocyte-derived serotonin. Pharmacological inhibition of 5-HT synthesis leads to inhibition of lipogenesis in epididymal white adipose tissue (WAT), induction of browning in inguinal WAT and activation of adaptive thermogenesis in brown adipose tissue (BAT). Fat specific Tph1 knock-out (Tph1 FKO) mice exhibit similar phenotypes as mice with pharmacological inhibition of 5-HT synthesis, suggesting the localized effects of 5-HT in adipose tissues. In addition, Htr3a KO mice exhibit increased energy expenditure in BAT and Htr2a KO mice exhibit the decreased lipid accumulation in WAT. These data suggest the clinical significance of the peripheral serotonergic system as a new therapeutic target for anti-obesity treatment.

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

The Advanced Voltage Regulation Method for ULTC in Distribution Systems with DG

  • Kim, Mi-Young;Song, Yong-Un;Kim, Kyung-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.737-743
    • /
    • 2013
  • The small-scaled onsite generators such as photovoltaic power, wind power, biomass and fuel cell belong to decarbonization techniques. In general, these generators tend to be connected to utility systems, and they are called distributed generations (DGs) compared with conventional centralized power plants. However, DGs may impact on stabilization of utility systems, which gets utility into trouble. In order to reduce utility's burdens (e.g., investment for facilities reinforcement) and accelerate DG introduction, the advanced operation algorithms under the existing utility systems are urgently needed. This paper presents the advanced voltage regulation method in power systems since the sending voltage of voltage regulators has been played a decisive role restricting maximum installable DG capacity (MaxC_DG). For the proposed voltage regulation method, the difference from existing voltage regulation method is explained and the detailed concept is introduced in this paper. MaxC_DG estimation through case studies based on Korean model network verifies the superiority of the proposed method.

Development of Operation and Control Technology of Energy Storage System for Frequency Regulation and Operation by Grid Connected Automatic Control (주파수조정용 에너지저장장치 운전제어 기술의 개발과 계통연계 자동제어 운전)

  • Lim, Geon-Pyo;Choi, Yo-Han;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.235-241
    • /
    • 2016
  • Grid-connected, large-capacity energy storage systems (ESS) can be used for peak load supply, frequency regulation, and renewable energy output smoothing. In order to confirm the capability of battery ESS to provide such services, 4MW/ 8MWh battery ESS demonstration facility was built in the Jocheon substation on Jeju Island. The frequency regulation technology developed for the Jocheon demonstration facility then became the basis for the 28MW and 24MW frequency regulation ESS facilities installed in 2014 at the Seo-Anseong and Shin-Yongin substations, respectively. The operation control systems at these two facilities were continuously improved, and their successful commercialization led to the construction of additional ESS facilities all over Korea in 2015. In seven (7) locations nationwide (e.g., Shin-Gimje and Shin-Gyeryeong), a total of 184 MW of ESS had been commercialized in 2016. The trial run for the new ESS facilities had been completed between April and May in 2016. In this paper, results of the trial run from each of the ESS facilities are presented. The results obtained from the Seo-Anseong and Shin-Yongin substations during a transient event by a nuclear power plant trip are also presented in this paper. The results show that the frequency regulation battery ESS facilities were able to quickly respond to the transient event and trial run of ESS is necessary before it is commercialized.

A Study on the Electricity Distribution Tariff Regulation of Ukraine to Encourage Private Investment on the AMI (AMI 사업에 민간투자를 유인하기 위한 우크라이나 배전서비스 요금정책 연구)

  • Kim, Chul-Nyuon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.19-26
    • /
    • 2021
  • A purpose of this study is to suggest distribution tariff regulation that encourages private investment on the energy efficiency industry of Ukraine. As the electricity market reform and the regulation introduction to encourage energy efficiency are ongoing in Ukraine, it is best time for Korean companies to enter to the market. Therefore, studies on the regulation and the market of Ukraine are required in advance. A simulation of private investment feasibility on AMI business is conducted on one of 32 DSOs in Ukraine. Through the simulation, the directions of RAB tariff regulation, which is the core of the distribution service tariff regulation, were derived. It is essential for DSOs to permit AMI lease assets, introduced by private investors, as regulated assets while other regulations are maintained as it is for investment. This study provides a practical basis by presenting objective data through simulation. It is expected to be helpful for overseas expansion of companies if the study is expanded to the various energy efficiency industries.

Modeling and Speed Control of a Horizontal Axis Wind Generator (수평축 풍력발전기의 모델링 및 속도제어)

  • Lim, J.H.;Boo, S.H.;Huh, J.C.;Kim, K.H.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • Wind turbine system converts wind energy into electric energy. Since the velocity of wind is random in nature, control of the angular velocity of the blade is necessary in order to generate high quality electric power. The control of a blade can be divided into a stall regulation and a pitch control types. The stall regulation type which is based on the characteristics of an aerodynamic stall of the blades is simple and cheap, but it suffers from fluctuation of the resulting power. Or the contrary, pitch control type is based on the fact that the torque of the blade can be changed by varying the pitch angle of the blade. It is mechanically and mathematically complicated, but the control performance is better than that of the stall regulation type. This paper suggests a method of denying a mathematical modeling of the wind turbine system, and develops a speed control algorithm by pitch control. The validity of the algorithm is demonstrated with the results produced through sets of simulation.

  • PDF

A Study on an Evaluation Modeling of Power System Performance for Frequency Regulation ESS Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 주파수조정용 ESS의 계통영향성 평가 모델링에 관한 연구)

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1024-1030
    • /
    • 2018
  • Recently, the large scaled energy storage system(ESS) which has various functions such as peak saving, demand management, output stabilization of renewable energy and frequency regulation(FR) is being energetically installed and operated. Especially, as the use case of frequency regulation ESS, the KEPCO has demonstrated the total of 376[MW] ESS since 2014. However, there are no operational experiences and international technical standards on frequency regulation application in ESS. Therefore, this paper propose the evaluation algorithm for power system performance of ESS by considering the frequency characteristics between governor of existing generator and frequency regulation ESS, in order to verify the power system performance of ESS. And also, this paper propose an evaluation modeling for small scaled power system including the existing generator, frequency control ESS and customer loads based on the PSCAD/EMTDC S/W. From the simulation results in 360[MW] model power system, it is confirmed that frequency regulation ESS has better performances than conventional generators.

A Study on the Causalities Among GDP, Electric Consumption, CO2 Emission and Environmental Regulation in Korea (한국의 경제성장, 전력소비량, 이산화탄소 배출량 및 환경규제 간 인과관계 분석)

  • Jin, Bo-young;Kim, Geun-u;Park, Jung-gu
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • The rapid climate change is strengthening carbon emissions regulations internationally. Korea is strongly pressed to accept the obligation to reduce greenhouse gases as one of the United Nations Framework Convention on Climate Change. This article analyzed the Granger causalities among environmental regulation, economic growth, electricity consumption, and CO2 emission in Korea, using unit root test, cointegration test, and vector error correction model. As the results, environmental regulation has shown the bidirectional causalities with electricity consumption and CO2 emission, while being unilaterally affected by economic growth in the long-run and strong relationship. Economic growth has affected electricity consumption, CO2 emission, and environmental regulation in the long-run, in the complex structure of the unilateral and short-run causality with electricity consumption and the bidirectional causality with CO2 emission. The policy implications will be as follows: ① environmental regulation should induce sustainable growth through encouraging technological innovation relating to CO2 reduction and productivity enhancement. ② Responding to the international CO2 reduction regulation, the synthetic policy initiatives will be considered to make synergy effects among policies relating to economic growth, electricity consumption.

Rulemaking Process of Electrical Safety Regulation for Fuel Cell Vehicles (연료전지 차량의 전기 안전성 규제안 작성 방법론)

  • Kim, Eal-Goo;Xi, Chen;Park, Jae-Hong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.2
    • /
    • pp.133-141
    • /
    • 2009
  • 본 논문에서는 전기자동차의 고전압 시스템의 안전성을 확보하기 위한 법규 규제안 생성 방법론을 제시하였다. 법규가 기술적으로 모든 영역을 빠뜨리지 않고 정의하고 있는지를 파악하기 위한 방법으로 법규분포분석법(Regulation Distribution Analysis Method)과 법규 완전도 분석법(Regulation Completeness Analysis Method)을 제시하였다. 자동차 설계와 생산에 있어서 법규/규제는 중요한 이슈가 되고 있다. 원칙적으로 법규는 자동차 승객과 환경을 보호하는 목적으로 생성되고, 이윤 추구 중심의 시장에서 놓칠 수 있는 기술적 항목들을 규제할 수 있도록 한다. 매연 배출 정도, 매연 모니터링 시스템, 전기 안전성과 같은 항목이 그 예이며, 향후 연료전기자동차 양산을 앞두고는 고전압 안전성과 관련된 규제 또한 필요하게 될 것으로 파악된다. 그러나 규제 항목에서 미정의된 부분이 있는지를 확인하는 체계적인 방법이 없어 본 논문에서는 기술적인 파라미터를 중심으로 규제항목을 검토하는 방법론을 제시하였다.