• 제목/요약/키워드: energy recovery.

검색결과 1,669건 처리시간 0.024초

엔진 냉각수 폐열 회수를 위한 랭킨 스팀 사이클용 보일러의 성능 설계 (Performance Design of Boiler for Waste Heat Recovery of Engine Coolant by Rankine Steam Cycle)

  • 허형석;배석정;황재순;이헌균;이동혁;박정상;이홍열
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.58-66
    • /
    • 2011
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop(HT loop) is a system to recover the waste heat from the exhaust gas, a low temperature loop(LT loop) is for heat recovery from the engine coolant cold relatively. This paper has dealt with a layout of a LT loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the LT boiler, a core part of a LT loop, has been presented and analytically investigated. Considering the characteristics of the cycle, the basic concept of the LT boiler has been determined as a shell-and tube type counterflow heat exchanger, the performance characteristics for various design parameters were investigated.

시멘트 산업 폐열 회수 현황 (Current Status of Waste Heat Recovery System in Cement Industry)

  • 김영진;서준형;김양수;권석제;조계홍;조진상
    • 자원리싸이클링
    • /
    • 제31권6호
    • /
    • pp.3-17
    • /
    • 2022
  • 이산화탄소 배출량 및 에너지 사용이 많은 시멘트 산업은 탄소중립 실현 및 지속적인 발전을 위한 전략이 필요하다. 에너지 효율 향상을 위해 국내 대부분의 시멘트 업체에서 폐열 회수 시스템을 구축하여 전력을 생산하고 있으나, 이와 관련된 에너지 재활용 연구는 거의 없는 실정이다. 시멘트 생산이 많은 국가에서는 기존의 폐열 회수 시스템을 보완하기 위해 온도에 따라 적용하는 랭킨사이클 변경, 작동유체 비교, 2단 이상의 랭킨 사이클 적용 및 타 산업과의 연계 등을 통해 폐열 회수를 극대화하기 위한 연구를 수행하는 것으로 확인되었다. 본 연구에서는 국내외 시멘트 산업에서의 폐열 회수 및 활용에 대해 정리하여 에너지 효율 향상을 위해 필요한 연구 방향을 도출하고자 하였다.

폐열회수환기를 위한 열교환장치의 경제성 평가 (An economic evaluation of heat exchanger for heat recovery ventilation)

  • 박용효;이상범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.241-244
    • /
    • 2008
  • Recently, The high Air-Tightness and high heat insulation for building construction cause a ventilation air volume deficiency. Also, Worldwide high energy price is strongly urging to economize the air conditioning energy. Therefore Heat Recovery Ventilation is used for the satisfaction of ventilation air volume and building energy saving. Accordingly, this study dose the heat exchanger performance evaluation and economic efficiency evaluation of Heat Recovery Ventilation. And, we wish to make a basic study about HRV System application of HVAC System and Multi System Air-conditioning.

  • PDF

유입 선회류에 대한 디퓨져 손실 및 난류특성에 관한 연구 (A Study on Pressure Loss and Turbulent Charactristics in a Conical Diffuser with a Swirl Flow)

  • 정효민;고대권;양정규
    • 수산해양기술연구
    • /
    • 제28권2호
    • /
    • pp.157-163
    • /
    • 1992
  • In this paper, the relationship between static pressure recovery and turbulent energy was presented in case of swirling flows into a conical diffuser. The distributions of turbulent energy in a diffuser sectional area were measured by a hot wire anemometer. The following conclusion can be drawn from the experiment. Diffuser loss is constituted by a dynamic pressure loss and total pressure loss. The static pressure recovery depends strongly on the total pressure loss. The static pressure recovery depends strongly on the total pressure loss, and the turbulent energy varies inversely as the static pressure recovery coefficient.

  • PDF

복합화력발전소의 냉각수 배열회수를 위한 히트펌프의 성능평가 (Analysis on the Performance Test Results of Heat Pump for the Closed Cooling Water Heat Recovery on Combined Thermal Power Plant)

  • 이성호
    • 한국유체기계학회 논문집
    • /
    • 제19권2호
    • /
    • pp.43-48
    • /
    • 2016
  • This study proves successes of Energy Service Company (ESCO) business by heat pump performance test. The purpose of ESCO business is recover investment costs through saving energy from installation of energy reduction facility. The most important technology assessment items are heat recovery and generator output. Experimental result shows that increase quality of heat recovery (11.52Gcal/h), while decrease generator output (0.234kw). In its final analysis, the ESCO business is successful according to our data.

Cesium and strontium recovery from LiCl-KCl eutectic salt using electrolysis with liquid cathode

  • Jang, Junhyuk;Lee, Minsoo;Kim, Gha-Young;Jeon, Sang-Chae
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3957-3961
    • /
    • 2022
  • Deposition behaviors of Sr and Cs in various liquid cathodes, such as Zn, Bi, Cd, and Pb, were examined to evaluate their recovery from LiCl-KCl eutectic salt. Cations in the salt were deposited on the liquid cathode, exhibiting potential of -1.8 to -2.1 V (vs. Ag/AgCl). Zn cathode had successful deposition of Sr and exhibited the highest recovery efficiency, up to 55%. Meanwhile, the other liquid cathodes showed low current efficiencies, below 18%, indicating LiCl-KCl salt decomposition. Sr was recovered from the Zn cathode as irregular rectangular SrZn13 particles. A negligible amount of Cs was deposited on the entire liquid cathode, indicating that Cs was hardly deposited on liquid cathodes. Based on these results, we propose that liquid Zn cathode can be used for cleaning Sr in LiCl-KCl salt.

폐기물부담금제 도입에 따른 인천시 폐기물의 에너지화 제고방안 연구 (A Study on Increasing the Energy Recovery from Waste at Incheon Metropolitan City according to Landfill Tax Introduction)

  • 임지영;김진한;박정환
    • 유기물자원화
    • /
    • 제23권2호
    • /
    • pp.21-27
    • /
    • 2015
  • 본 논문은 자원순환사회 구축을 목표로 필요한 재원마련을 위해 도입예정인 폐기물부담금제에 대응하기 위한 폐기물의 에너지화 제고방안을 인천시를 중심으로 평가하고 폐기물부담금제 도입을 위해 고려하여야 할 사항들을 제안하였다. 인천시의 폐기물 에너지화를 위한 주요 문제점으로 파악된 음식물 류폐기물의 반입량 감소에 따른 폐기물의 고발열량화, 종량제봉투에 혼입되어 배출되는 금속류, 건전지 등을 해결하기 위한 대책을 도출하였다.

피에조 펌프 구동용 에너지 회수형 하이브리드 구동장치 고성능 운전에 관한 연구 (A Study on High Performance Operation of Hybrid Energy Recovery Drive System for Piezoelectric Pump)

  • 홍선기;이정섭;조용호;김기석;강태삼
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1426-1431
    • /
    • 2015
  • Piezoelectric pump can be considered as R-C load and it needs something special driver because the output voltage does not become 0 even though the applied voltage is 0 with common converter. This operating system consists of fly-back converter to increase the input voltage and energy recovery inverter to apply square voltage to the piezoelectric pump. The energy recovery inverter can charge and discharge the energy of capacitive load. In this paper, to enhance performance of the driver, a few elements or circuits are added and modified. To drive the inverter safely, current limit resister is added and adjusted the value to valance the charging and discharging current. In addition, a current limit inductor is added to the input side to limit the input current and enhance the efficiency. Inductor only may make oscillation and another resister is added parallel to the inductor to solve this problem. The converter and inveter are assembled to one board for compactness. The appropriateness is proved with simulation and experiments.

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

블루수소 생산을 위한 이산화탄소 포집용 2단 분리막 공정 최적화 연구 (Membrane-Based Carbon Dioxide Separation Process for Blue Hydrogen Production)

  • 박진우;이준협;허소연;여정구;심재훈;임진혁;이충섭;김진국;이정현
    • 멤브레인
    • /
    • 제33권6호
    • /
    • pp.344-351
    • /
    • 2023
  • 본 연구에서는 중공사형 이산화탄소 분리막 모듈을 사용하여 수소개질기 배가스로부터 이산화탄소 포집을 목적으로 한 분리막 공정 최적화 연구를 진행하였다. 랩스케일의 소형 분리막 모듈을 사용하여 혼합기체를 대상으로 이산화탄소 순도 90% 및 회수율 90%을 달성하는 2단 공정 조건을 도출하였다. 막 면적이 정해진 모듈의 분리막 공정에서는 스테이지-컷, 주입부 및 투과부 압력에 따라서 포집 순도 및 회수율이 모두 다르게 나타나기 때문에 운전 조건에 대한 최적화가 필수적이다. 본 연구에서는 다양한 운전 조건에서 1단 분리막에서 보이는 공정 포집 효율의 한계를 확인하고, 높은 순도와 회수율을 동시에 달성하기 위한 2단 회수 공정을 최적화하였다.