• 제목/요약/키워드: energy consumption curve

검색결과 66건 처리시간 0.025초

집단에너지 공동주택의 사용자 측 열부하 예측에 의한 열공급제어 알고리즘 개발에 관한 연구 (A Study on Development of Heat Supply Control Algorithm of Consumer Group Energy Apartment Building by Prediction of Heating Load)

  • 변재기;이규호;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1300-1305
    • /
    • 2009
  • The energy conservation in buildings affects environmental preservation as well as economic benefits, and creates the comfortable indoor environment set for the inhabitants. Especially, apartment buildings show ever-increasing energy consumption with large-sized and high-class tendency, thus energy saving counterplans are needed. The present study is to develop an optical control algorithm by using heating load curve according to the outdoor temperature change. Heating load analysis should be performed before the present method can be applied. Dynamic heating load simulations are performed by resistance-capacitance method. Results show that heating load decrease linearly according to the increase of outdoor temperature.

  • PDF

가스 엔진 VRF시스템의 에너지 실사용량 & 시뮬레이션 평가와 전기 구동 VRF 시스템과의 성능비교에 관한 연구 (Evaluation of actual Energy consumption & Simulation of Gas Engine VRF System and Comparison with Electric VRF System)

  • 최슬건;전종욱;김강수
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.67-74
    • /
    • 2017
  • Purpose: As the recent climate environment changes so rapidly, environmental problems such as hot weather and fine dust have occurred, and interest in environmental policies and technology development is increasing in countries around the world. Similarly in the Architecture, researches to reduce greenhouse gas emissions and to reduce energy application are actively conducted. Looking at previous studies, it is analyzed that the electric VRF is more energy efficient than the gas engine VRF. However, energy costs have changed due to recent price hikes and discounts on gas charges due to high electricity consumption in summer. Method: In this study, the actual building of Gas Engine VRF system was modeled using SketchUp program, and EnergyPlus was used to simulate actual building. Also, Electric VRF system was simulated, and compared with Gas Engine VRF system. Result: The total secondary energy requirement of Electric VRF system was 19.6% less than that of the Gas Engine VRF system, But when analyzing with primary energy requirement, EHP used 15.8% more energy. CO2 emissions were also estimated to be 16.9% more EHP. Energy costs were 14.8% more in Electric VRF systems, because their electricity charges are 0.6 to 160% more expensive than gas charges.

다각형을 통과하는 곡선의 최적화 (Finding Optimized Curves Passing through a Polygon)

  • 추연웅;구자영
    • 한국정보처리학회논문지
    • /
    • 제5권9호
    • /
    • pp.2388-2394
    • /
    • 1998
  • 제어점들이 주어지지 않고 다각형이 주어질 때 그 다각형의 내부를 통과하는 곡선을 생성하는 방법을 제안하였다. 다각형의 볼록 분할을 통해 제어점들을 선정하였으며 곡선 세그먼트의 1차 연속성을 만족시키면서 2차 불연속성을 극소화하는 방법과 점성 저항 하에서 곡선 세그먼트의 1차 연속성을 만족시키면서 소비 에너지를 극소화하는 방법을 제안하였다.

  • PDF

Microgrid energy scheduling with demand response

  • Azimian, Mahdi;Amir, Vahid;Haddadipour, Shapour
    • Advances in Energy Research
    • /
    • 제7권2호
    • /
    • pp.85-100
    • /
    • 2020
  • Distributed energy resources (DERs) are essential for coping with growing multiple energy demands. A microgrid (MG) is a small-scale version of the power system which makes possible the integration of DERs as well as achieving maximum demand-side management utilization. Hence, this study focuses on the analysis of optimal power dispatch considering economic aspects in a multi-carrier microgrid (MCMG) with price-responsive loads. This paper proposes a novel time-based demand-side management in order to reshape the load curve, as well as preventing the excessive use of energy in peak hours. In conventional studies, energy consumption is optimized from the perspective of each infrastructure user without considering the interactions. Here, the interaction of energy system infrastructures is considered in the presence of energy storage systems (ESSs), small-scale energy resources (SSERs), and responsive loads. Simulations are performed using GAMS (General Algebraic modeling system) to model MCMG, which are connected to the electricity, natural gas, and district heat networks for supplying multiple energy demands. Results show that the simultaneous operation of various energy carriers, as well as utilization of price-responsive loads, lead to better MCMG performance and decrease operating costs for smart distribution grids. This model is examined on a typical MCMG, and the effectiveness of the proposed model is proven.

전력 소비의 용도별 경제적 편익 평가 (Assessment of the Economic Benefits from Electricity Consumption)

  • 임슬예;박재형;유승훈
    • 에너지공학
    • /
    • 제24권2호
    • /
    • pp.9-16
    • /
    • 2015
  • 전력은 인간의 생존과 산업생산에 있어서 필수적인 투입요소이다. 전력의 소비로부터 경제적 편익이 발생하며, 특히 전력소비의 경제적 편익은 전력과 관련된 정책의 다양한 분야에서 중요한 정보로 활용된다. 이에 본 연구에서는 전력소비로 인해 발생하는 경제적 편익을 평가하고자 한다. 전력소비의 경제적 편익은 소비자 지출과 소비자 잉여의 합으로 구성되는 전력 수요함수 아랫면적이다. 이때 소비자 지출은 쉽게 관측되는 반면에 소비자 잉여를 계산하기 위해서는 수요의 가격탄력성에 대한 정보가 필수적으로 요구된다. 본 연구에서는 주택용, 산업용, 일반용 전력을 대상으로 하며, 문헌 조사를 통해 전력의 용도별 가격탄력성에 대한 정보를 유추한다. 용도별 전력 수요의 가격탄력성은 각각 -0.332, -0.351, -0.263으로 추정되었다. 2013년을 기준으로 추정된 전력 1kWh 소비의 소비자 잉여는 각각 191.54원, 143.44원, 231.91원이며, 2013년 기준 전력의 용도별 평균가격은 각각 127.02원, 100.70원, 121.98원이므로, 전력소비자의 경제적 편익은 각각 318.56원, 244.14원, 353.89원이다. 소비자 물가지수를 이용하여 이 값을 2014년 기준으로 환산하면 주택용, 산업용, 일반용 순으로 각각 321.96원, 246.75원, 357.67원이다. 이 값은 전력공급사업의 경제성 분석에서 중요한 정보로 활용될 수 있다.

룰 베이스를 이용한 공조기의 고장검출 및 진단 (Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases)

  • 한도영;주명재
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

무선 센서 네트워크에서 에너지 효율을 고려한 모바일 sink의 적응적 경로설정 방법 (Adaptive Mobile Sink Path Based Energy Efficient Routing Protocol for Wireless Sensor Network)

  • 김현덕;윤여웅;최원익
    • 한국통신학회논문지
    • /
    • 제36권12A호
    • /
    • pp.994-1005
    • /
    • 2011
  • 본 논문에서는 센서 네트워크 환경에서 에너지 효율적인 mobile sink node의 최적의 경로를 설정 할 수 있는 방법인 AMSP(Adaptive Mobile Sink Path)를 제안한다. 기존의 논문들은 mobile sink node 이동시 random way point 방식을 사용하여 불필요한 데이터 전송으로 인한 에너지 소모를 야기했다. 또한, sink node의 이동이 random으로 이동하기 때문에 같은 지역을 중복으로 이동할 수 있는 단점이 있다. 이를 해결하기 위하여 본 논문에서 제안하는 방법은 센서 노드가 설치되어진 필드의 크기에 따라 정적인 그리드를 생성하고 그리드 안에서 mobile sink node가 이동하는 최적의 경로를 설정하여 준다. 이 경로는 네트워크의 크기, 밀도에 따라 효율적인 경로 탐색을 위해 이동 경로를 변경하여 준다. 또한 각각의 노드가 mobile sink node의 주행 경로 및 속도를 인지하고 있음으로 데이터 전송에 대한 에너지 소모량을 감소시킬 수 있다. 이렇게 sink node의 위치를 예상할 수 있기 때문에 에너지의 추가적인 절약을 위해 일정 시간 동안 sleep상태로 두고 active와 교대하는 duty cycle을 사용한다. 이 기법을 사용하여 본 논문에서는 기존의 방법들인 TTDD나 CBPER에 비해 최대 80% 이상의 에너지 소모량을 감소시킬 수 있는 것으로 나타났다.

패널분석을 이용한 6대 권역별 대기오염물질에 대한 환경규제와 경제성장 간의 상호관계분석: EKC(환경쿠즈네츠곡선)가설을 중심으로 (The correlation among the GHG (Greenhouse Gas) emission, energy consumption and economic growth for the 6 specific regions in Korea by using Panel approaches:By Testing of the EKC(Environmental Kuznets Curve))

  • 박추환
    • 환경정책연구
    • /
    • 제12권2호
    • /
    • pp.59-86
    • /
    • 2013
  • 1988년부터 2008년까지의 자료를 바탕으로 우리나라 6개 권역을 대상으로 권역별 소득, 환경규제, 오염유발원이 각 권역별 대기오염 물질(황산화물, 질소산화물, 총먼지, 일산화탄소)에 미치는 영향을 지역적 관점에서 살펴보았다. 즉, 환경 쿠즈네츠 곡선(EKC)가설 검증차원에서 공해배출과 경제성장 간의 관계를 패널회귀분석을 통해 분석하였다. 분석 결과, 산업시설에 영향을 미치고 있는 황산화물(SOx)의 경우 대부분의 권역에서 EKC가설이 성립하는 것으로 나타났지만, 질소산화물(NOx)과 총먼지(TSP)의 경우 6개 권역 중 대경권에서만 EKC가설이 성립하는 것으로 나타났 으며, 일산화탄소(CO)의 경우에도 EKC가설을 충족시키는 권역은 중부권, 호남권, 동남권에 한정되어 있었다. 또한 각 권역별 대기오염 단속규제가 대기오염과 정(+)의 관계를 보임에 따라 환경규제효과가 나타난다고 보기 어려우며, 각 권역별 연료소비와 석유화학제품의 특화 또한 권역별 대기오염을 증가시키는 주요 요인으로 작용하고 있다.

  • PDF

Effect of Glucose-Sweetened Drinks on Blood Glucose, Energy, and Water Intake at a Meal 3h Later in Healthy Males

  • Kim, Seok-Young
    • Nutritional Sciences
    • /
    • 제9권4호
    • /
    • pp.280-287
    • /
    • 2006
  • The aims of this study were to describe the effects of glucose-sweetened drinks on blood glucose, energy, and water intake at a meal 3 hours later. The effect of blood glucose on prandial energy intake and the relationship between water and energy intake during a meal were also determined. Twenty healthy normal-weight men were fed pizza test meals 3h after consuming four drinks of 0, 50g, 65g, and 75g glucose in random order, within-subjects design. Blood samples were measured at baseline and every 30 min after ingestion of drinks and 30min after the end of the test meal and the appetite was also assessed by visual analog test at the same interval. The results of this study showed that various glucose drinks altered blood glucose responses compared with that of water control(p<0.0001). Blood glucose areas under the curve(AUC) for glucose-sweetened drinks were significantly(p<0.05) higher than that for the control over 3 hours after a drink and 30 min after the test meal. Consumption of the glucose-sweetened drinks significantly increased(p<0.05) energy and water intake at a test meal compared with the water control, except the drink containing 75g glucose. For all drinks combined, the energy intake was negatively correlated with the blood glucose and positively correlated with the volume of water consumed at a test meal at 3 hours later.

Large Cryosorption Pump for the NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.27-32
    • /
    • 2003
  • A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.

  • PDF