• 제목/요약/키워드: endoscope

Search Result 251, Processing Time 0.023 seconds

Direction Sensor Design for Reducing Perforation Risk in Endoscopy (천공부작용 해소용 내시경 Direction Sensor 설계)

  • Kang, Sang-man;Park, Dea-woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.836-845
    • /
    • 2017
  • Due to the development of endoscopic technology, endoscopic diagnosis and procedures have been actively performed. However, due to the increase in colorectal cancer and the effect of government's early cancer screening project, the number of endoscopic diagnosis and procedures has increased, thus medical accidents such as perforation and bleeding are increasing. Therefore, efforts to reduce such medical accidents are needed. In this paper, we propose a method to provide the direction information of the endoscope and the force applied to the probe in real time. We also propose and evaluate an interpolated complementary filter considering the very slow movement of the endoscope probe. The proposed interpolated complementary filter showed 34.6% and 27.6% performance improvement. The expected user interface for applying the proposed method to the endoscopic system is also presented. This shows that the proposed method is applicable to endoscopy system.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

Technological Trend of Endoscopic Robots (내시경 로봇의 기술동향)

  • Kim, Min Young;Cho, Hyungsuck
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.3
    • /
    • pp.345-355
    • /
    • 2014
  • Since the beginning of the 21st century, emergence of innovative technologies in robotic and telepresence surgery has revolutionized minimally access surgery and continually has advanced them till recent years. One of such surgeries is endoscopic surgery, in which endoscope and endoscopic instruments are inserted into the body through small incision or natural openings, surgical operations being carried out by a laparoscopic procedure. Due to a vast amount of developments in this technology, this review article describes only a technological state-of-the arts and trend of endoscopic robots, being further limited to the aspects of key components, their functional requirements and operational procedure in surgery. In particular, it first describes technological limitations in developments of key components and then focuses on the description of the performance required for their functions, which include position control, tracking, navigation, and manipulation of the flexible endoscope body and its end effector as well, and so on. In spite of these rapid developments in functional components, endoscopic surgical robots should be much smaller, less expensive, easier to operate, and should seamlessly integrate emerging technologies for their intelligent vision and dexterous hands not only from the points of the view of surgical, ergonomic but also from safety. We believe that in these respects a medical robotic technology related to endoscopic surgery continues to be revolutionized in the near future, sufficient enough to replace almost all kinds of current endoscopic surgery. This issue remains to be addressed elsewhere in some other review articles.

Relationship between electrical stimulus strength and contraction force from the inside of small intestine (전기 자극 강도에 따른 소장 내부에서의 수축력 관계)

  • Woo, S.H.;Kim, T.W.;Lee, J.H.;Park, H.J.;Moon, Y.K.;Won, C.H.;Lee, S.H.;Park, I.Y.;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, capsule endoscope was developed to observe small intestine in human body. However, the capsule does not have any locomotive ability, which reduces the benefit of the capsule endoscope. Many researches have done to give locomotion to the capsule, still it consumes too much power to generate the motion by small battery. One of the moving method is electrical stimulus that consumes less power than many methods. The electrical stimulus method causes contraction in the small intestine, and it moves the capsule. Some of papers showed it is possible to guide the capsule by electrical stimulus, however the relationship between electrical stimulus at the mucous and contraction force in the small intestine is not reported, yet. In this paper, the mucous in the small intestine was stimulated, and measured the contraction force in the small intestine is shown. The result shows, the relationship between electrical stimulus parameters (voltage, duration) and contraction force. Also, equation between electrical stimulus parameters and contraction force is roughly induced.

Design and Implementation Endoscope System for Endotracheal Intubation (기관 내 삽관을 위한 내시경 시스템 설계 및 구현)

  • Kim, H.S.;Kang, S.K.;Kim, G.Y.;Han, Y.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.153-160
    • /
    • 2015
  • With the development of recent IT fusion technology, IT fusion technology of medical equipment has been dramatically development. The need to most basic preferential implementation of emergency is the respiration of the patient, it is necessary to first aid is maintained in emergency patients airway simultaneously. However, to the endotracheal intubation is a procedure to secure the airway, it requires experience and first aid, Inc. good career, very that may lead to sequelae in patients who otherwise have failed to procedures It is a sensitive and important procedure. For these reasons, the success rate of current endotracheal intubation technique is not at a high level and about 50 percent. In an attempt to complement these problems, in this paper, in the process of endotracheal intubation, intubated by inserting an endoscopic camera to Into Activation tube, the streaming is a real-time monitoring and wireless video transmission method using, there is a purpose of enabling the monitoring in smart devices increase the success rate of endotracheal intubation of first aid purchases.

  • PDF

Evaluation of Image qualify in Super-resolution Image Guide for Ultrathin Endoscope (미세 내시경용 고 분해능 영상가이드의 성능 평가)

  • Choi W.Y.;Oh C.H.;Lee B.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.233-237
    • /
    • 2000
  • In general. fiber-optic medical endoscopes are made from glass step index (SI) fibers. These endoscopes have limitations in both image quality and mechanical properties. In particular. the image resolution of the SI endoscopes is limited to about 5$\mu$m. In this study the image resolution of plastic graded index (GRIN) super-resolution image guides with pixel sizes from 7 to 2.5 $\mu$m were measured and compared with those of 91ass SI image guides. There is an improvement in resolution of the plastic GRIN image guides as the microfiber diameter is reduced from 7 $\mu$m to 2.5 $\mu$m. The measured resolution of plastic GRIN image guide with 2.5 $\mu$m microfibers is more than a factor of two higher than that of g1ass SI image guide with 5$\mu$m microfibers. This new design of optical systems could have a major impact on a wide array of future optical systems used in defense. industrial, and medical applications.

  • PDF

Diagnostic Ability of High-definition Imaging Using Ultraslim Endoscopes in Early Gastric Cancer

  • Sugita, Tomomi;Suzuki, Sho;Ichijima, Ryoji;Ogura, Kanako;Kusano, Chika;Ikehara, Hisatomo;Gotoda, Takuji;Moriyama, Mitsuhiko
    • Journal of Gastric Cancer
    • /
    • v.21 no.3
    • /
    • pp.246-257
    • /
    • 2021
  • Purpose: It is unclear whether high-definition (HD) imaging improves visibility and diagnostic ability in early gastric cancer (EGC) compared with standard-definition (SD) imaging. We aimed to compare the diagnostic performance and visibility scores of HD and SD ultraslim endoscopes in EGC. Materials and Methods: We used HD and SD ultraslim endoscopes to obtain 60 images with similar compositions of gastric environments. Of the 60 images, 30 showed EGC (15 images for each modality) and 30 showed no EGC (15 images for each modality). Seventeen endoscopists evaluated the presence and location of the lesions in each image. Diagnostic ability was compared between modalities. The color difference between a lesion and the surrounding mucosa (ΔE) was measured and compared between the modalities. Results: The ability of HD to detect EGC was significantly higher than that of SD (accuracy: 80.8% vs. 71.6%, P=0.017; sensitivity: 94.9% vs. 76.5%, P<0.001; positive predictive value, 76.2% vs. 55.3%, P<0.001; and negative predictive value (NPV), 94.1% vs. 73.5%, P<0.001). The ability of HD to determine the horizontal extent of EGC was significantly higher than that of SD (accuracy: 71.0% vs. 57.8%, P=0.004; sensitivity: 75.3% vs. 49.0%, P<0.001; NPV, 72.9% vs. 55.9%, P<0.001; and area under the curve: 0.891 vs. 0.631, P=0.038). The mean ΔE was significantly higher for HD than for SD (10.3 vs. 5.9, P=0.011). Conclusions: The HD ultraslim endoscope showed a higher diagnostic performance in EGC than the SD endoscope because it provided good color contrast.

Performance of UWB System in dispersive human body (분산 인체채널에서의 UWB시스템 성능분석)

  • Woo, Sun-Keol;Won, Hyun-Jun;Yang, Hoon-Gee
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • This paper make an analysis of UWB Communication System. In case endoscope, medical equipment, is applied to UWB, We could study through body-channel that frequency transmitted of received signal is differ from wireless in the existing air. It suggested TR-UWB form, non-coherent received method in dispersion-medium like humans bodies by accomplishing ability analysis of BPM, TR, BER of Differential, UWB Communication modulation and demodulation form.

  • PDF

Deep Learning based Computer-aided Diagnosis System for Gastric Lesion using Endoscope (위 내시경 영상을 이용한 병변 진단을 위한 딥러닝 기반 컴퓨터 보조 진단 시스템)

  • Kim, Dong-hyun;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.928-933
    • /
    • 2018
  • Nowadays, gastropathy is a common disease. As endoscopic equipment are developed and used widely, it is possible to provide a large number of endoscopy images. Computer-aided Diagnosis (CADx) systems aim at helping physicians to identify possibly malignant abnormalities more accurately. In this paper, we present a CADx system to detect and classify the abnormalities of gastric lesions which include bleeding, ulcer, neuroendocrine tumor and cancer. We used an Inception module based deep learning model. And we used data augmentation for learning. Our preliminary results demonstrated promising potential for automatically labeled region of interest for endoscopy doctors to focus on abnormal lesions for subsequent targeted biopsy, with Az values of Receiver Operating Characteristic(ROC) curve was 0.83. The proposed CADx system showed reliable performance.

The Obturator Guiding Technique in Percutaneous Endoscopic Lumbar Discectomy

  • Han, In-Ho;Choi, Byung-Kwan;Cho, Won-Ho;Nam, Kyoung-Hyup
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.182-186
    • /
    • 2012
  • In conventional percutaneous disc surgery, introducing instruments into disc space starts by inserting a guide needle into the triangular working zone. However, landing the guide needle tip on the annular window is a challenging step in endoscopic discectomy. Surgeons tend to repeat the needling procedure to reach an optimal position on the annular target. Obturator guiding technique is a modification of standard endoscopic lumbar discectomy, in which, obturator is used to access triangular working zone instead of a guide needle. Obturator guiding technique provides more vivid feedback and easy manipulation. This technique decreases the steps of inserting instruments and takes safer route from the peritoneum.