• 제목/요약/키워드: emergency valve system

검색결과 44건 처리시간 0.024초

과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안 (A Safety Plan for the Pumping Station by Hydraulic Transient Analysis and Demonstration)

  • 라병필;김진만;이동근;박종호;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.22-28
    • /
    • 2005
  • As the water supply facilities are recently getting larger, the domestic waterworks become multi-regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment plant and water supply/distribution facilities. Although the pumping stations and the pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. In this paper, the intake pumping station is guaranteed by both the computer simulation and the field test analysis. This study is contributed to the safe operation program for the pumping station in which results of the adjustment on the safety plan of the pumping station, the air valve and the valve closing time.

과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안 (The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration)

  • 라병필;김진만;박종호;김경엽
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구 (A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor)

  • 변윤섭
    • 한국가스학회지
    • /
    • 제24권4호
    • /
    • pp.32-38
    • /
    • 2020
  • 화학반응기에 발생한 화재·폭발 사고사례를 기반으로 화학반응기에 설치되어 있는 예방조치의 문제점을 분석하였다. 화학반응기는 다품종의 화학제품을 생산하며, 반응폭주시 급격히 상승하는 압력을 해소하기 위해 파열판을 설치하고 파열판의 기능을 유지하기 위해 배출물질을 대기로 배출하도록 허용하고 있어 화재·폭발사고가 발생하였다. 이를 개선하기 위한 방안으로 안전건전성수준(SIL3)을 기반으로 한 안전계장시스템(SIS)을 화학반응기의 예방조치로 적용하였다. 화학반응기의 원재료를 적하하는 배관에 긴급차단밸브를 직렬로 2개 설치하여 반응폭주시 긴급차단밸브 2개 중 1개만 작동하여도 원재료 공급을 차단할 수 있도록 하고, 반응응제제 공급배관에는 자동 ON/OFF 밸브를 병렬로 설치하여 반응폭주시 1개의 밸브만 열려도 반응억제제가 투입될 수 있게 하였다.

$\cdot$무선 데이터 통신을 이용한 천연가스 정압소의 안전방재 시스템 개발 (Development of Anti-disaster System for Natural Gas Governor Station Using Wire and/or Wireless Communication)

  • 유휘룡;박대진;구성자;박승수;노용우
    • 한국가스학회지
    • /
    • 제3권2호
    • /
    • pp.17-23
    • /
    • 1999
  • 본 연구는 전국에 산재된 천연가스 정압소를 위한 안전방재 시스템 개발을 위하여 수행되었다. 정압소에서 발생할 수 있는 사고를 미연에 방지하기 위하여 정압소의 안전상황을 수집/전송하는 RTU(Remote Terminal Unit)를 개발하여 정압소의 운전원의 역할을 대신하게 하였다. 그리고 전송된 각 정압소의 안전상황을 효과적으로 통제소 운전원에게 전달하며 추후 안전에 대한 분석을 위하여 데이터베이스 및 MMI(Man Machine Interface)를 개발하였다. 안정적인 천연가스 공급의 모든 프로세스을 제어하며, 각종 파라미터를 감시하는 원방 감시 제어 시스템(이하 SCADA 시스템)의 유선 통신 설비가 사고에 의해 무용화 될 경우, 정압소의 상황을 통제실로 전송하기 위하여 유선 및 무선 데이터 통신을 혼합한 유$\cdot$무선 자동 전환 시스템을 개발하였다. 한편 GPS(Global Position System) 및 GIS(Geometric Information System) 기술을 이용한 순찰차량 관리 시스템을 개발하여 정압소에서 이상 징후를 보일 경우 통제소 및 순찰차량에서 동시에 정압소의 상황을 파악할 수 있게 하여 능동적인 대처가 가능하게 하였다. 그리고 3축 가속도 센서를 이용하여 지진을 감지하고 전송하는 지진 감지 및 전송 시스템을 개발하였다. 지진 발생시 ESV(Emergency Shutoff Valve)를 차단할 수 있도록 최대 지반 가속도 및 SI(Spectrum Intensity)값의 크기를 전송해 줌으로서 대형사고를 방지하도록 하였다.

  • PDF

디젤발전기 엔진 상태 진단 기술의 발전소 적용 연구 (A Study on the Power Plant Application of Engine Condition Diagnosis Technology for Diesel Generator)

  • 최광희;이상국
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel generator of nuclear power plant has a role for supply of emergency electric power to protect reactor core system in event of loss of off-site power supply. Therefore diesel generator should be tested periodically to verify the function that can supply specified frequency and voltage at design power level within limited time. For this purpose, appropriate maintenances in case that abnormal conditions were found are required in allowed time. In this paper, results of development of engine condition diagnosis technology and study on power plant of its technology for diesel generator are described.

연료전지 자동차 내 수소 공급 시스템에서 드레인 밸브 특성에 따른 드레인 로직 최적화 및 연비와 운전안정성을 고려한 물 관리 전략 개발 (Optimization of Condensate Water Drain Logic Depending on the Characteristics of Drain Valve in FPS of Fuel Cell Vehicle and Development of Anode Water Management Strategy to Achieve High Fuel Efficiency and Operational Stability)

  • 안득균;이현재;심효섭;김대종
    • 한국수소및신에너지학회논문집
    • /
    • 제27권2호
    • /
    • pp.155-162
    • /
    • 2016
  • A proton exchange membrane fuel cell (PEMFC) produces only water at cathode by an electrochemical reaction between hydrogen and oxygen. The generated water is transported across the membrane from the cathode to the anode. The transported water collected in water-trap and drained to the cathode within the humidifier outlet. If the condensate water is not being drained at the appropriate time, condensate water in the anode can cause the performance degradation or fuel efficiency degradation of fuel cell by the anode flooding or unnecessary hydrogen discharge. In this study, we proposed an optimization method of condensate water drain logic for the water drain performance and the water drain algorithm as considered the condensate water generating speed prep emergency case. In conclusion, we developed the water management strategy of fuel processing system (FPS) as securing fuel efficiency and operating stability.

무효전력 보상여유를 고려한 SVC와 ULTC의 협조제어 (Coordinated Control of SVC and ULTC Considering Reactive Power Compensation Margin)

  • 문경섭;손광명;이태기;이송근;박종근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.351-357
    • /
    • 1999
  • This paper proposes the coordinated control of SVC and UTLC at the distribution substation to get larger operating margin of SVC for the voltage stability control by reactive power compensation. In the conventional method, ULTC doesn't respond to the variation of source voltage, so SVC has the entire responsibility for it. It could cause the lack of operating margin of SVC in some condition. It, however, is important to secure an operating margin for the dynamic stability control in emergancy. This paper proposes the coordinated control method that SVC controls the supply voltage and ULTC respond to the SVC compensation valve based on the relation between SVC compensation and ULTC tap position. The numerical simulation verifies that the proposed system could increase the operating margin of SVC compared with the conventional system.

  • PDF

임베디드 시스템을 이용한 가택의 긴급상황 감시 시스템에 대한 연구 (A Study on Home's Emergency Monitoring System Using Embedded System)

  • 최재우;양승현;노방현;황희융
    • 한국산학기술학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-64
    • /
    • 2004
  • 32비트 RISC 프로세서인 PXA255기반 보드에 임베디드 리눅스 운영체제와 HTTP(Hyperfext Transfer Protocol) 웹서버를 포팅하여 사용자의 웹 브라우져 상에서 원격지 가택에 대한 실시간 감시가 가능한 시스템을 구현하였다. 웹 서버는 GoAhead 웹 서버2.1 버전을 교차 컴파일하여 사용하였으며 가택감시를 위한 아날로그 신호에 대한 입력을 프로세서가 받기 위해 ADC(Analog to Digital Convertor)칩인 ADC0809를 사용하였다 ADC를 위한 디바이스 드라이버를 작성하였으며 이를 웹 브라우져 상에서 실시간적으로 변하는 데이터를 모니터링하기위해 클라이언트 풀(Clieilt Pull)방식을 사용한 CGI-C 응용프로그램을 개발하였다. 감시가 가능한 요소로는 온도, 조도 그리고 가스 유출여부이며 가스 밸브와 현관문의 개폐상태를 확인할 수 있게 하였고 긴급 상황 발생시 경고음을 발생하도록 하였다 최근 홈 디지털 서비스 중에 사용자가 가장 필요로 하는 긴급 상황에 대한 감시 요구를 내장형 시스템을 사용하여 보다 적은비용으로 구현하였다.

  • PDF

A study on the dynamic characteristics of the secondary loop in nuclear power plant

  • Zhang, J.;Yin, S.S.;Chen, L.;Ma, Y.C.;Wang, M.J.;Fu, H.;Wu, Y.W.;Tian, W.X.;Qiu, S.Z.;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1436-1445
    • /
    • 2021
  • To obtain the dynamic characteristics of reactor secondary circuit under transient conditions, the system analysis program was developed in this study, where dynamic models of secondary circuit were established. The heat transfer process and the mechanical energy transfer process are modularized. Models of main equipment were built, including main turbine, condenser, steam pipe and feedwater system. The established models were verified by design value. The simulation of the secondary circuit system was conducted based on the verified models. The system response and characteristics were investigated based on the parameter transients under emergency shutdown and overload. Various operating conditions like turbine emergency shutdown and overspeed, condenser high water level, ejector failures were studied. The secondary circuit system ensures sufficient design margin to withstand the pressure and flow fluctuations. The adjustment of exhaust valve group could maintain the system pressure within a safe range, at the expense of steam quality. The condenser could rapidly take out most heat to avoid overpressure.

천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가 (A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities)

  • 고재선;김효
    • 한국화재소방학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-20
    • /
    • 2003
  • 천연가스는 서울에서 새로운 도시가스로서 지하배관망루 벨브스테이션을 통하여 공급되어 왔다. 그러나 천연가스는 편리함과는 대조적으로 운송시스템의 오류 또는 부주위한 취급으로부터 화재 및 폭발을 야기할 수 있는 매우 실제적인 잠재위험성을 가지고 있다. 따라서 이 연구의 주요 목적은 전형적인 배관망을 구성하는 공급설비의 신뢰성을 평가한 후 주요 잠재위험성의 확인 및 위험성평가를 수행하는 것이다. 본 연구에서는 Fault Tree Analysis와 Event free Analysis에 의해 서울의 임의의 지점 두 곳을 설정하여 최종적인 단계(top event)로서 밸브기지의 소규모 누출과 대규모 누출, 각 도시가스회사로의 천연가스공급중단을 설정하여 각각에 대한 발생빈도의 값을 알아보았다. 그 결과 소규모 누출시 DC, DS 밸브기지에 대하여 각각 3.29, 1.41의 값으로 나타났으며, 대규모 누출에 대하여는 1.90$\times$$10^{-2}$, 2.32$\times$$10^{-2}$, 또한 도시가스회사로의 천연가스공급중단에 대한 각각의 기지에 대한 수치는 2.33$\times$$10^{-2}$, 2.89$\times$$10^{-2}$로 나타났다. 또한 단위 지역 공급설비에 대한 전체적인 신뢰도와 기기별 신뢰도의 계산함으로서 기기와 공급망간의 상호관계성의 인식과, 전체 설비 굽에서 중요한 부분과 좀더 강조되어야 할 부분을 찾아내기 위해 Minimal Cut Set 방법을 사용한 결과, DC 밸브기지의 경우, 기기단위별로는 6, 7, 26, 27 등이 취약함을 보여주고 있으며, 또한 basic event 26, 27의 조합으로 인한 천연가스공급중단의 위험이 가장 크므로 이 부분에 대해서 하나의 라인이 병렬로 추가되어야만 좀더 안정적이고 위험부담이 적은 시스템으로 운영할 수 있다. 이러한 경우 공급중단의 고장율이 1/4로 줄어드는 효과를 가지게 된다. DS 밸브기지의 경우, basic event 4가 천연가스공급중단의 원인의 92%를 차지하고 있다. 그러므로 이 부분의 portion을 낮춰준다면 전체의 고장율도 낮춰질 수가 있고 이 부분에 같은 종류의 라인을 추가로 설치하면 고장율이 약 1/10로 줄어드는 효과를 보게 된다. 또한 기기단위별로는 6, 7, 26, 27 등이 가장 취약한 것으로 나타났다. 이 부분에 대해서는 안전장치나 설비를 추가로 갖추거나, 혹은 점검기간의 주기를 줄이도록 하는 것이 필요하다. 향후 본 연구에서 다루어진 신뢰도 측정방법을 각 공급설비에 대해 적용한다면 좀 더 효율적으로 공급설비의 신뢰도를 계산, 분석할 수 있고, 천연가스공급설비의 안전성 향상에 도움이 될 것으로 기대된다.