• Title/Summary/Keyword: emergency exit

Search Result 95, Processing Time 0.09 seconds

An Analysis of Dwelling Environment of Public Retirement(Silver) Housing Based on Post Occupancy Evaluation (거주 후 평가(P.O.E)에 의한 공공실버주택의 거주환경 분석)

  • Bak, Da-Hye;Kim, Young-Hwa;Lee, Sang-Hong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.65-76
    • /
    • 2018
  • Due to the rapid demographic and structural changes, Korea has faced a variety of social issues and quickly entered the aged society since the 2000s. In order deal with this reality, diverse types of welfare policies are emerging in the society as a whole. The government began to supply domestic public silver housing in 2016 to provide against the quickly growing aged society and now, the government is planning to supply approximately 50,000 housing by 2022 for quantitative growth of aged society, by selecting 1st and 2nd designated areas for the project additionally. This public retirement(silver) housing combines 'space' with 'service'. The lower floors are a public silver welfare Facilities and the upper floors are a housing spaces. This type of housing is to deal with requirements of rental housing residents by combining physical space with supporting service. Based on barrier-free design, the complex and unit house have safety handles and alarm bells in the bathroom, undulating washstands, bathroom sliding doors, corridor safety handles, and emergency safety exit lamps in each housing unit so the aged and the disabled can use easily and conveniently. Also, hand rails are installed and stepped pulleys are removed to promote convenience. Currently, the government is planning to increase the supply, focusing on low-income groups, such as beneficiaries of national basic livelihood and the working poor. Recognizing that the public retirement(silver) housing project is at its early stage, this study examined satisfaction, based on evaluations of real residents. This study aimed to obtain more empirical research data and apply them to public retirement(silver) house space analysis. For analysis, this study targeted Wirye public retirement(silver) housing and Magnolia public retirement(silver) housing that are in operation, and literature review, previous research review, and field survey were conducted to examine the present state. Using the questionnaires consisting of four large classification items; Block Layout, Housing Unit, Welfare Facilities, and Barrier-free Design, and sub-details, a survey was conducted to analyze residents' satisfaction. In conclusion, it is anticipated that this study would serve as basic research data about public retirement(silver) housing to increase continuously in future by analyzing public retirement(silver) housing spaces, on the basis of the analyzed data.

A Study on Ways to Improve Safety Management through Analysis of Fire Cases in Multiple-user Buildings (다중이용업소의 화재사례 분석을 통한 안전관리 개선방안 연구)

  • Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.191-201
    • /
    • 2022
  • In this study, we are going to derive problems for fire and safety management in multiple-user Buildings and suggest improvement measures to prevent recurrence through analysis of legal operation status for safety management of multiple-user Buildings and case studies of large-scale fires in multiple-user Buildings. For this study, first, the current state of the industry and fire occurrence status were investigated through theoretical considerations of the multi-use industry, and then the previous research on the multi-use industry was analyzed. and by analyzing the legal and institutional status of multiple-user Buildings, problems were derived through cases such as the Jecheon fire in Chungcheongbuk-do, the Inhyeon-dong fire in Incheon, and the Songpa-gu fire in Seoul. As a result, first, the necessity of strengthening the initial fire response capability. Second, thorough maintenance and management of emergency exits. Third, the need for rational regulation of upholstery. Fourth, reinforcement of fire safety education and training. Fifth, strengthening of installation standards for firefighting and safety facilities. Sixth, we derive the result that it is necessary to raise awareness about safety management, compare and analyze it with legal and institutional contents, and suggest solutions accordingly. When looking at the causes of fires in multi-use buildings, building owners, business owners, and employees think that there is no possibility of a fire occurring in their business premises, so there is a lack of awareness. It is necessary to raise awareness through education and publicity of firefighters and related administrative agencies.

Study on collapse mechanism and treatment measures of portal slope of a high-speed railway tunnel

  • Guoping Hu;Yingzhi Xia;Lianggen Zhong;Xiaoxue Ruan;Hui Li
    • Geomechanics and Engineering
    • /
    • v.32 no.1
    • /
    • pp.111-123
    • /
    • 2023
  • The slope of an open cut tunnel is located above the exit of the Leijia tunnel on the Changgan high-speed railway. During the excavation of the open cut tunnel foundation pit, the slope slipped twice, a large landslide of 92500 m3 formed. The landslide body and unstable slope body not only caused the foundation pit of the open cut tunnel to be buried and the anchor piles to be damaged but also directly threatened the operational safety of the later high-speed railway. Therefore, to study the stability change in the slope of the open cut tunnel under heavy rain and excavation conditions, a 3D numerical calculation model of the slope is carried out by Midas GTS software, the deformation mechanism is analyzed, anti-sliding measures are proposed, and the effectiveness of the anti-sliding measures is analyzed according to the field monitoring results. The results show that when rainfall occurs, rainwater collects in the open cut tunnel area, resulting in a transient saturation zone on the slope on the right side of the open cut tunnel, which reduces the shear strength of the slope soil; the excavation at the slope toe reduces the anti-sliding capacity of the slope toe. Under the combined action of excavation and rainfall, when the soil above the top of the anchor pile is excavated, two potential sliding surfaces are bounded by the top of the excavation area, and the shear outlet is located at the top of the anchor pile. After the excavation of the open cut tunnel, the potential sliding surface is mainly concentrated at the lower part of the downhill area, and the shear outlet moves down to the bottom of the open cut tunnel. Based on the deformation characteristics and the failure mechanism of the landslides, comprehensive control measures, including interim emergency mitigation measures and long-term mitigation measures, are proposed. The field monitoring results further verify the accuracy of the anti-sliding mechanism analysis and the effectiveness of anti-sliding measures.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

A Study of Detainees' Perceptions of the Detention Facilities of the Police Station and their Operation (경찰서 유치장 시설 및 운영에 관한 유치인의 인식연구)

  • Jung, Woo-Yeoul;Park, Dong-Kyun;Kim, Do-Kyun
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.423-449
    • /
    • 2007
  • This research is to investigate the detention facilities of police stations and their real operations through the perceptions of detainees at police station cells and to present the policy suggestions for them. To fulfill the research, a questionnaire was made out on the basis of 'the Regulation on Detention and Escort for Suspects'. 'the Regulation on a Standard Plan for Detention Facilities' and 'the Regulation on the Lowest Standard to Treat Detainees' ; and detainees at 23 police station cells under the jurisdiction of Kyungbuk Local Police Agency were asked to answer it. Policy suggestions following from the result of the investigation of detainees' perceptions of the detention facilities of the police stations are as follows; Firstly, the structure of police station cells should be arranged in straight lines in order to take their human rights into consideration and more detention facilities are needed to be built in order to separate male, female, handicapped and juvenile inmates. Secondly, shower rooms and washrooms outside the cells should always be open to detainees whenever they need to be used. Thirdly, any detention facilities deficient in fire fighting equipment should have exit doors installed as soon as possible in case of an emergency and provide sufficient fire extinguishers considering the number of detainees and the size of the facilities. Fourthly, the detention facilities should have sufficient windows for ventilation and take necessary measures to obtain natural lighting instead of electric lighting. Fifthly, air conditioners should be equipped properly taking account of the number of detainees and the dimensions of the facilities. Policy suggestions according to the result of the investigation of detainees' perceptions of the operation of detention facilities of police stations are as follows; Firstly, the problem of operating the detention facilities must deal with worn-out facilities and measures to secure the budget should be taken as soon as possible. Secondly, considering that most detained suspects have difficulties in livelihood, daily necessaries must be issued to them. Thirdly, personal belongings deposited by inmates must be properly managed with the same documentation throughout the police station detention facilities. The number of female guards to take exclusive charge of the physical checkups and processing of female detainees should be increased. Also the facilities for handicapped detainees must be expanded, improved and managed properly. Fourthly, except for handcuffs and ropes to bind detainees in the detention facilities, helmets to prevent self-harm must be withdrawn. The budget to improve the quality of meal issued by the government must be urgently secured and the price of private food sent to detainees must be readjusted to be in line with the consumer price. Health and medical care and sanitation for detainees must be substantial, and also sunbathing and outdoor exercises should be allowed to detainees.

  • PDF