• Title/Summary/Keyword: embeded

Search Result 174, Processing Time 0.022 seconds

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

A Study on the Efficiency of Hand-Knee Position in GB Stone Ultrasonography (담낭결석 초음파검사에서 Hand-Knee position의 효율성에 관한 연구)

  • Park, Soung-Ock;Do, Yun-Su
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.267-274
    • /
    • 2006
  • The evaluation of GB stones with ultrasound has proved to be useful procedure in patient with symptoms of cholelithiasis. GB is evaluated for size, wall thickness, presence of internal reflections within the lumen and posterior acoustic shadowing or enhancement in Ultrsonography. The patient position should be shifted during procedure to demonstrate further the presence of stone within the GB. Patient scanned at the Rt. subcostal region in supine, right lateral, Lt. down decubitus, and upright sitting position. So GB stone should shift to dependent area of GB. Often, GB is not markedly distended in the presence of cholethiasis, and so the diagnosis becomes more difficult. One of the more difficult areas for detection of a GB stones are embeded in the cystic duct region. And since the GB is adjacent to the duodenum and hepatic flexure, its may be difficult to visualizing a GB stone. When patient study position changes frome supine to other position, stones displaced the site. But if its are polyps, not changes the site whatever patient positions. It is very important to what make different GB stones or polyps. We have studied about mobility of GB stones according to the patients position(supine, Lt. down decubitus, $30^{\circ} LAO. sitting and hand-knee). So we have a result, stones wherever localized within the GB, changed 100% its position in the hand-knee position and the others appeared at least 90%. In this study, when a large stones are located through fundus-body and body-neck, does not changing the stones position in spite of varied patient's positions. But hand-knee positions can identified GB stones, because its make changed the position of stons from posterior wall to anterior wall within the GB. We recommend the hand-knee position for differentiation GB stones from polyps.

  • PDF

EFFECT OF VARIOUS RESIN CEMENTS TO THE SHEAR BOND STRENGTH IN THE ADHESION BRIDGE (접착성가공의치에서 세멘트 종류가 전단결합강도에 미치는 영향)

  • Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.791-799
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength of adhesion bridge by various resin cements. One hundred and foully 1st premolars were used. The teeth were cut below 2mm from CEJ and the coronal portions were used. The coronal portions were embeded with the acrylic resin and trimmed with sic paper until the flat plane with ${\phi}$ 4mm above acrylic resin sticks in height 5mm were casted with nonprecious metal and the using surfaces were treated with sic paper from #200 to #1200 and polished with alminum oxide paste. And then, the using surfaces were sandblasted and treated with the electrochemical etching. The teeth were divided into three groups of fourty two each. In group I, teeth and specimens were cemented with Panavia 21 In group II, teeth and specimens were cemented with Superbond In group I, teeth and specimens were cemented with All-Bond & composite resin cement Each group was subdivided into three subgroups according to the storage period ; one-day storage, fifteen-day storage, and thirty-day storage. The special jig was made. Then, the specimen and jig were mounted to Instron Universal Testing Machine and the failure were measured. The results were as follows. 1. There was statisfically significant difference between the failure loads of group I and group II and III after one day storage(P<0.01), 2. There was statisfically significant difference between the failure loads of group II and group I and III and between group I and group III at fifteen day storage(P<0.01). 3. There was statisfically significant difference between the failure loads of group I and II and group III after thirty day storage(P<0.01). 4. There was statisfically significant difference between the failure loads of one day storage and fifteen and thirty days storages in group III (P<0.01).

  • PDF

Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs (수종의 고정성 보정장치에 따른 유성견의 치주조직 반응)

  • Jo, Myung-Hun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.85-95
    • /
    • 2001
  • The purpose of this study was to evaluate the material for fixed type retainer, allowing physiologic tooth movement. and proper remodeling or periodontal tissue during retention period. The Present study was Performed to observe the histologic changes of periodontal tissue after application of different types of fixed type retainer after orthodontic tooth movement in young adult dogs. For this study, 4 young adult dogs were used as a experimental animal and experimental group was divided into three groups : experimental group 1 contained right side maxillayy third incisors and canines, experimental group 2 contained contralateral teeth of same animals, and control group contained mandibular premolars. And each dogs were applied the 4 different types of fixed type retainer to experimental group 1. The experimental teeth were ligated on the Sentalloy closed coil $spring^{\circledR}$(Tomy Co., Japan) from maxillary third incisors and canines and applied orthodontic force at initial 200gm-forced during 1 week. All the experimental animals were sacrificed on the 3rd week after the orthodontic teeth movement and then the specimens were taken, fixed in formalin, embeded in parafin, sectioned $6-8{\mu}m$ in thickness and stained with Hematoxylin-Eosin staining, and Masson's trichrome staining method. Examined under the light microscopy The following results were observed. 1. There were observed that decreased infiltration of giant tells in pressure side and increased the new bone forming in tension side on the specimen of 6-stranded 0.0195' $Respond^{\circledR}$(G&H Co., U.S.A.) group. Periodontal ligament fibers were much compressed or elongated in 3-stranded 0.018', 0.020' $Dentaflex^{\circledR}$(Dentarum Co., Germany), and Superbond $C&B^{\circledR}$(Sun Medical Co., Japan) groups. 2. In experimental group 1, necrotic bone inside the alveolar bone of pressure side, forming of the sharpey's fiber in osteoid tissue, and remodeling of the periodontal ligament were observed in all animals. 3. In experimental group 2, it was observed that the amount of bone resorption was equal or decreased in pressure side, and increased new bone forming and significantly decreased infiltration of giant cell than the experimental group 1. By this results, it considered that 6-stranded $Respond^{\circledR}$(G&H Co., U.S.A.) wire was the most useful material allowing early periodontal tissue remodeling.

  • PDF