• 제목/요약/키워드: electrostatic field

검색결과 303건 처리시간 0.035초

2단 평행판 전기집진기의 방전부 특성 실험 (Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner)

  • 김익생;이재옥;김용진;최헌오
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

실험실 규모 정전기 분무형 반건식 세정기의 SO2 제거효율 향상에 대한 계산 및 실험적 연구 (Numerical and Experimental Study on the Increase of Removal Efficiency of SO2 in a Laboratory Scale Electrostatic Spray Drying Absorber)

  • 변영철;황정호
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1111-1120
    • /
    • 1998
  • Spray Drying Absorber(SDA) system, where the combustion product gas is mixed with atomized limestone-slurry droplets and then the chemical reaction of $SO_2$ with alkaline components of the liquid droplets forms sulfates, has been widely used to eliminate $SO_2$ gas from coal fired power plants and waste incinerators. Liquid atomization is necessary because it can maximize the reaction efficiency by increasing the total surface area and dispersion angle of the alkaline components. First, numerical calculations using FLUENT are carried out to investigate $SO_2$ concentration distribution and thus to calculate $SO_2$ removal efficiency. So to attain the optimized spray conditions, then an electrostatic spraying system is set up and spray visualization is performed to show the effect of an electric field on overall droplet size. Next, the effect of an electric field on the concentrations of $SO_2$ is experimentally examined. Field strength is varied from -10 kV to 10 kV and configurations of conduction charging and induction charging are utilized. Consequently, the electrostatic removal efficiency of 501 increases about 30% with the applied voltage of ${\pm}10kV$ but is independent of polarity of the applied voltage. It Is also found that the conduction charging configuration results in higher efficiency of $SO_2$ removal that the induction charging configuration. Finally, the effect of slurry temperature on $SO_2$ removal is studied. The temperature influences on the electrostatic removal efficiency of $SO_2$.

입자와 액적간의 정전기적 응집을 통한 미세입자의 효율적인 제어 (Effective Control of fine Particles Using an Electrostatic Coagulation Between Particle and Water Droplet)

  • 이명화;김상범;황유성;김종호;김경수
    • 한국분무공학회지
    • /
    • 제11권2호
    • /
    • pp.98-104
    • /
    • 2006
  • A charged droplet scrubber was introduced to remove visible smokes generated in many industrial facilities. Lab-scale and field tests were conducted in this study. The system consists of a corona discharger to effectively charge the fine particles, fellowed by an electrostatic chamber to promote coagulation between charged fine particles and oppositely charged droplets and a demister to remove resultant particles. Overall collection efficiency, 98.4% was obtained from a lab-scale test, when a high voltage was applied to an ionizer and a charged droplet scrubber. Field tests also show the high collection efficiencies, 93.5% with one stage and 99.4% with two stage system. This system can be used to increase the collection efficiency of the conventional air pollution control devices to satisfy the national emission standard.

  • PDF

집진기내 입자 포집과 비산 문제에 대한 수치적 연구 (Numerical Study of Particle Collection and Entrainment in Electrostatic Precipitator)

  • 김주현;권순철;권기환;이상환;이주희
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.27-35
    • /
    • 2012
  • A numerical simulation for particle collection efficiency in a wire-plate electrostatic precipitator (ESP) has been performed. Method of characteristics and finite differencing method (MOC-FDM) were employed to obtain electric field and space charge density, and lattice boltzmann method (LBM) was used to predict the Electrohydrodynamic (EHD) flow according to the ion convection. Large eddy simulation (LES) was considered for turbulent flow and particle simulation was performed by discrete element method (DEM) which considered field charging, electric force, drag force and wall-collision. One way coupling from FDM to LBM was used with small and low density particle assumption. When the charged particle collided with the collecting plate, particle-wall collision was calculated for re-entertainment effect and the effect of gravity force was considered.

외부 전기장내의 단일 섬유에 대한 먼지층 형사 수치 모사 (Numerical Simulation of Particle Deposition Pattern on Cylindrical Fiber under External Electrical Field)

  • 박현설;정용원;박영옥;이규원
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.41-51
    • /
    • 1999
  • In this study, the two dimensional morphology of particle accumulates on a cylindrical fiber was numerically simulated when a uniform external electric field was present across a cylindrical fiber. In order to investigate the mechanism of linear dendrite formation which is observed under the above electrostatic condition, the electrostatic forces between a newly introduced particle and each deposited particle were calculated and compared with those between the particle and fiber As a result of this study it was found that dielectrophoretic forces between the oncoming particle and fiber play principal roles in linear dendrite formation.

  • PDF

비정질 실리콘 박막을 이용한 Sodalime-Sodalime 정전 열 접합 및 FEA Packaging 응용 (Sodalime-sodalime Electrostatic Bonding using Amorphous Silicon Interlayer and Its Application to FEA Packging)

  • 주병권;이덕중;최우범;김영조;이남양;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.656-661
    • /
    • 1999
  • As a fundamental study for FED tubeless packaging, sodalime-sodalime electrostatic bonding was performed by using on the developed bonding mechanism. Thebonding properties of the bonded sodalime-sodalime structure were investigated through SEM and SIMS analyses. Mo-tip FEA was vacuum-packaged by the developed bonding process and the packaged device generated the field emission current.

  • PDF

광폭 전기집진기의 집진 특성에 관한 수치적 연구 (A Numerical Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator)

  • 김용진;홍원석;정상현;하병길;하대홍;유주식
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1205-1213
    • /
    • 2001
  • The electrical characteristics and particle collection efficiency of a wide-plate spacing electrostatic precipitator are numerically investigated, and the results are compared with those obtained experimentally. The electric potential and field strength near the collection plate increase with increasing the plate spacing. The electric field strength of a discharge electrode of a twisted pin type is larger than that of a rectangular type. As the roughness factor of the discharge electrode wire becomes small, or the plate spacing becomes narrow, the corona current of the precipitator increases. The numerical results agree well with those obtained from experimental method.

  • PDF

자기방전식제건기에 의한 대전물체의 제전 및 방전특성 (A Study on Characteristics of De-electrification and Discharge of Self-Discharged Electrostatic Reducer)

  • 박수덕;이동훈
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.72-76
    • /
    • 1995
  • An electrostatic passive neutralizer without HV power source has been used widely to reduce charges on insulators such as running plastic films, papers and cloths, but its elimination characteristics and safely have been hardly investigated in detail. Especially, an operation of the passive neutralizer depends primarily on the charged insulator and the elimination ability does not depend on only the neutralizer, because an electrostatic elimination is caused by corona discharges occurring between the passive neutralizer and charged insulator. From a reason described above, the purpose of this study is to examine experimentally the elimination ability of the passive neutralizer. Experiments were made on the corona discharges between the passive neutralizer and charged insulator running at high velocity in practical field to make clear the setting condition of the passive neutralizer for operating effectively and safely. Results obtained from field experiments are presented in this paper.

  • PDF

다중빔 리소그래피를 위한 초소형 컬럼의 전자빔 광학 해석에 관한 연구 (Study on The Electron-Beam Optics in The Micro-Column for The Multi-Beam Lithography)

  • 이응기
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.43-48
    • /
    • 2009
  • The aim of this paper is to describe the development of the electron-beam optic analysis algorithm for simulating the e-beam behavior concerned with electrostatic lenses and their focal properties in the micro-column of the multi-beam lithography system. The electrostatic lens consists of an array of electrodes held at different potentials. The electrostatic lens, the so-called einzel lens, which is composed of three electrodes, is used to focus the electron beam by adjusting the voltages of the electrodes. The optics of an electron beam penetrating a region of an electric field is similar to the situation in light optics. The electron is accelerated or decelerated, and the trajectory depends on the angle of incidence with respect to the equi-potential surfaces of the field. The performance parameters, such as the working distances and the beam diameters are obtained by the computational simulations as a function of the focusing voltages of the einzel lens electrodes. Based on the developed simulation algorithm, the high performance of the micro-column can be achieved through optimized control of the einzel lens.

  • PDF

CNT-BASED FIELD EMISSION X-RAY SOURCE

  • Kim, Hyun Suk;Lee, Choong Hun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.433-433
    • /
    • 2016
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission. CNT yarns have demonstrated its potential as excellent field emitters. It was demonstrated that a small focal spot size was achieved by manipulating some electrical parameters, such as applied bias voltage at the mesh gate, and electrostatic focal lenses, geometrical parameters, such as axial distances of the anode, and the electrostatic focal lens from the cathode assembly, and the dimension of the opening of the electrostatic lens. Electrical-optics software was used to systematically investigate the behavior of the electron beam trajectory when the aforementioned variables were manipulated. The results of the experiment agree with the theoretical simulation results. Each variable has an individual effect on the electron beam focal spot size impinging on the target anode. An optimum condition of the parameters was obtained producing good quality of X-ray images. Also, MWCNT yarn was investigated for field emission characteristics and its contribution in the X-ray generation. The dry spinning method was used to fabricate MWCNT yarn from super MWCNTs, which was fabricated by MW-PECVD. The MWCNT yarn has a significant field emission capability in both diode and the triode X-ray generation structure compared to a MWCNT. The low-voltage-field emission of the MWCNT yarn can be attributed to the field enhancing effect of the yarn due to its shape and the contribution of the high-aspect-ratio nanotubes that protrude from the sides of the yarn. Observations of the use of filters on the development of X-ray images were also demonstrated. The amount of exposure time of the samples to the X-ray was also manipulated. The MWCNT yarn can be a good candidate for use in the low voltage field emission application of X-ray imaging.

  • PDF