• 제목/요약/키워드: electrospray coating

검색결과 18건 처리시간 0.021초

새로운 촉매 코팅법을 이용한 직접 개미산 연료전지의 성능 분석 (Performance Analysis of The Direct Formic Acid Fuel Cell using A New Catalysis Coating Method)

  • 권용재;권병완;김진수;김이영;정원석;한종희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.29-32
    • /
    • 2008
  • The cell performance of direct formic acid fuel cell (DFAFC) having catalysts coated by electrospray was analyzed. Pd catalyst was used for the anode electrode and Pd catalyst loading amount and formic acid feed rate dependances of fuel cell performance were evaluated. When loading amount of Pd is in between 3mg/$cm^2$ and 7mg/$cm^2$ and formic acid feed rate is 5ml/min., 3mg/$cm^2$ sample showed better potential at 129 mA/$cm^2$ and power density due to difference in mass transfer limitation. However, when the feed rate is greater than 10ml/min., the opposite tendency was observed between 3mg/$cm^2$ and 7mg/$cm^2$ samples. The result was attributed to improvement in electrochemical reaction of the Pd. Based on the above results, In DFAFC including Pd catalyst that was coated by electrospray, 0.537V as the maximum potential at 129 mA/$cm^2$ was attained.

  • PDF

rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study (Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study)

  • 이우성;김성균;허성주;곽재영;이주희;박지만;박윤경
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.298-304
    • /
    • 2014
  • 목적: 본 선행 연구는 recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/ poly lactic-co-glycolic acid (PLGA) 복합체를 타이타늄 임플란트에 처리하였을 때 골 유착에 미치는 영향을 알아보기 위해 시행된 것으로 토끼 모델을 사용하였다. 재료 및 방법: 8개의 임플란트를 300V에서 3분 동안 양극 산화하였다. 그 중 4개는 electrospray법으로 rhTGF-${\beta}2$/PLGA를 코팅하여 실험군으로 설정하였다. 4마리의 New Zealand rabbit의 tibiae에 1개씩의 실험군과 대조군 임플란트를 식립하였으며, 3주와 6주에 2마리씩 희생하여 micro-computed tomography(microCT) 촬영 후 분석하였다. 결과: Scanning electron microscope (SEM) 사진에서 rhTGF-${\beta}2$/PLGA 입자가 임플란트 표면에 균일하게 분산되어 있음을 확인하였다. MicroCT 분석 결과 통계적으로 유의하지는 않지만 rhTGF-${\beta}2$/PLGA를 처리한 임플란트가 bone volume/total volume (BV/TV)와 trabecular thickness (Tb.Th) 값이 더 높은 경향성을 보였으며, cross sectional view에서 더 많은 골이 형성되었음을 확인하였다. 결론: rhTGF-${\beta}2$/PLGA 표면처리된 임플란트가 주변 골의 양적 성장을 촉진시킬 수 있으며 임플란트 초기 골 유착을 증진시킬 수 있는 가능성을 보였다.

Study of Energy Level Alignment at the Interface of P3HT and PCBM Bilayer Deposited by Electrospray Vacuum Deposition

  • Kim, Ji-Hoon;Hong, Jong-Am;Seo, Jae-Won;Kwon, Dae-Gyoen;Park, Yong-Sup
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.134-134
    • /
    • 2012
  • We investigated the interface of poly (3-hexylthiophene) (P3HT) and C61-butyric acid methylester (PCBM) by using photoelectron spectroscopy (PES). These are the most widely used materials for bulk heterojunction (BHJ) organic solar cells due to their high efficiency. Study of the BHJ interfaces is difficult because the organic films are typically prepared by spin coating in ambient conditions. This is incompatible with the interface electronic structure probes such as PES, which requires ultrahigh vacuum conditions. Study of interface requires gradual deposition of thin films that is also incompatible with the spin coating process. In this work, we used electrospray vacuum deposition (EVD) technique to deposit P3HT and PCBM in high vacuum conditions. EVD allows us to form polymer thin films onto ITO substrate in a step-wise manner directly from solutions and to use PES without exposing the sample to the ambient condition. Although the morphology of the EVD deposited P3HT films observed by optical and atomic force microscopes is quite different from that of the spin coated ones, the valence region spectra were similar. PCBM was deposited on the P3HT film in a similar manner and the energy level alignment between these two materials was studied. We discuss the relation between Voc of P3HT:PCBM solar cell and HOMO-LUMO energy offset obtained in this study.

  • PDF

생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동 (Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents)

  • 김동민;이봉수;박철호;박귀덕;손태일;정명호;한동근
    • 폴리머
    • /
    • 제34권2호
    • /
    • pp.178-183
    • /
    • 2010
  • 의료용 금속스텐트는 관상동맥계 심장질환을 앓고 있는 환자에 시술되어 상대적으로 생존율을 높여 준다. 그러나, 재협착 및 후기 혈전증으로 인하여 새로운 스텐트의 개발이 시급하게 되었다. 이러한 문제점을 해결하기 위해서 신생내막 과대증식을 막을 수 있는 것으로 알려진 alpha lipoic acid(ALA)를 생분해성 고분자인 poly(lactide-coglycolide)(PLGA), poly(L-lactide)(PLLA) 및 poly($\varepsilon$-caprolactone)(PCL)과 혼합하여 전기분사 방식으로 스테인레스 스틸 표면 위에 코팅하였다. 코팅된 고분자로부터 약물방출 거동은 고분자의 종류와 농도, 용출속도 및 용매의 종류에 따라서 조사하였다. 약물방출 속도는 유리전이온도($T_g$)가 낮은 PCL에서 가장 빨랐으며 PLGA, PLLA 순서를 보였다. 고분자 표면의 거친정도는 용출속도가 증가함에 따라서 증가하였고, 용매의 비등점의 차이에 의해서 약물방출속도가 변화됨을 알 수 있었다. 이러한 약물방출 거동을 조절함으로써 ALA가 담지된 생분해성 고분자로 코팅된 약물방출 스텐트를 실제 임상적용이 가능할 것으로 기대된다.

금 나노입자 형성을 이용한 계층구조 SiO2 코팅층의 제조 및 표면 특성 (Synthesis and Surface Properties of Hierarchical SiO2 Coating Layers by Forming Au Nanoparticles)

  • 김지영;김은경;김상섭
    • 한국재료학회지
    • /
    • 제23권1호
    • /
    • pp.53-58
    • /
    • 2013
  • Superhydrophobic $SiO_2$ layers with a micro-nano hierarchical surface structure were prepared. $SiO_2$ layers deposited via an electrospray method combined with a sol-gel chemical route were rough on the microscale. Au particles were decorated on the surface of the microscale-rough $SiO_2$ layers by use of the photo-reduction process with different intensities ($0.11-1.9mW/cm^2$) and illumination times (60-240 sec) of ultraviolet light. With the aid of nanoscale Au nanoparticles, this consequently resulted in a micro-nano hierarchical surface structure. Subsequent fluorination treatment with a solution containing trichloro(1H,2H,2H,2H-perfluorooctyl)silane fluorinated the hierarchical $SiO_2$ layers. The change in surface roughness factor was in good agreement with that observed for the water contact angle, where the surface roughness factor developed as a measure needed to evaluate the degree of surface roughness. The resulting $SiO_2$ layers revealed excellent repellency toward various liquid droplets with different surface tensions ranging from 46 to 72.3 mN/m. Especially, the micro-nano hierarchical surface created at an illumination intensity of $0.11mW/cm^2$ and illumination time of 60 sec showed the largest water contact angle of $170^{\circ}$. Based on the Cassie-Baxter and Young-Dupre equations, the surface fraction and work of adhesion for the micronano hierarchical $SiO_2$ layers were evaluated. The work of adhesion was estimated to be less than $3{\times}10^{-3}N/m$ for all the liquid droplets. This exceptionally small work of adhesion is likely to be responsible for the strong repellency of the liquids to the micro-nano hierarchical $SiO_2$ layers.

전기분사를 이용한 양성담관 협착 치료용 약물방출 스텐트 개발 (Development of Drug Eluting Stent for the Treatment of Benign Biliary Stricture by Electro-spray Method)

  • 신일균;김동곤;김한기;김상호;전동민;서태석;장홍석
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.163-168
    • /
    • 2012
  • 최근에 내시경 관련기술의 진보에 따라서 시술 편리성, 회복시간 단축, 환자 고통 경감 등의 장점으로 인해 스텐트 삽입술이 빠르게 진보하였다. 본 연구에서 양성담관 협착 치료를 목적으로 파클리탁셀을 이용한 약물방출 스텐트를 전기분사 방법에 의해 제조하였으며, 이 때 사용된 고분자는 polyether-based polyurethane(상표명 : PELLETHANE 2363-80AE$^{(R)}$)과 첨가제로서 Pluronic F127, 약물로서 파클리탁셀을 사용하여 금속스텐트 표면에 코팅하였다. 그 결과로서, 약물이 코팅된 고분자 필름의 물리적 특성은 SEM, FTIR, 접촉각 측정기, XRD에 의해 확인하였으며, 약물방출속도는 약물함량이 높을수록 감소하였음을 알 수 있었다.

Electrospray법으로 rhTGF-β2/PLGA 복합체를 코팅한 티타늄에서의 간엽줄기세포 증식에 관한 연구 (An in vitro study of mesenchymal stem cell proliferation on titanium discs coated with rhTGF-β2/PLGA by electrospray)

  • 김주형;김성균;허성주;곽재영;이우성;이주희;박지만
    • 대한치과보철학회지
    • /
    • 제54권2호
    • /
    • pp.120-125
    • /
    • 2016
  • 목적: 본 연구는 in-vitro 상에서 recombinant human transforming growth factor-beta (rhTGF-${\beta}2$)와 poly(D,L-lactide-co-glycolide) (PLGA) 의 복합체를 티타늄 디스크 표면에 코팅하여, 생물학적으로 간엽줄기세포 증식에 미치는 영향을 조사하기 위해 시행되었다. 재료 및 방법: 양극산화 디스크에 일렉트로스프레이 코팅법을 이용하여 anodized 된 티타늄 디스크를 대조군으로 설정하고, rhTGF-${\beta}2$를 125 ng/ml와 500 ng/ml 농도로 코팅한 것을 실험군으로 하였다. 티타늄 디스크 표면에 분사된 복합체가 균일하게 분사되었는지 field-emission scanning electron microscopy (FE-SEM)을 통해 확인하였으며, atomic force microscope (AFM) test를 이용하여 rhTGF-${\beta}2$로 코팅한 디스크와 양극산화 디스크의 거칠기 차이를 확인하였다. 디스크 위에 간엽줄기세포 배양 후 1, 4, 7일에 세포증식 양상을 MTT (3-(4,5-dimethylthiazol-2-yl)-2,5 diphenyl-tetrazolium bromide) assay 검사를 통해 확인하였다. 결과: AFM 결과 대조군과 실험군에서 거칠기의 유의할만한 차이가 없었다 (P>.05). MTT 결과 7일차 배양 결과에서 125 ng/ml와 500 ng/ml PLGA/TGF-${\beta}2$처리된 그룹은 각각 평균 0.45와 0.48이였으며, 대조군은 평균 0.33으로 PLGA/TGF-${\beta}2$처리된 그룹에서 세포 증식이 더 활성화 되는 것을 확인할 수 있었다 (P<.05). 결론: rhTGF-${\beta}2$ 복합체를 electrospray법으로 코팅한 티타늄 표면에서 7일차에서 줄기간엽세포의 빠른 증식을 확인하였다. 또한 복합체 처리군의 농도가 증가할수록 높은 세포 성장 수치를 보였다.

Electrospray법을 이용한 MS275/PLGA submicron 코팅 티타늄에서의 표면변화와 간엽줄기세포증식에 관한 연구 (A study of mesenchymal stem cell proliferation and surface characteristics of the titanium discs coated with MS275/PLGA by an electrospray)

  • 유수연;김성균;허성주;곽재영;이주희;박윤경;김에나
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.285-291
    • /
    • 2012
  • 연구 목적: 본 실험은 MS275와 PLGA (poly lactic-co-glycolic acid) 의 복합체를 submicron 크기로 티타늄 디스크 표면에 코팅하여, 표면의 변화를 알아보고 생물학적으로 간엽 줄기세포 활성에 어떠한 영향을 미치는지 조사하기 위해 시행되었다. 연구 재료 및 방법:양극산화 디스크에 electrospray 코팅법을 이용하여PLGA를 분사한 것을 대조군으로 설정하고, MS275를 $0.5{\mu}M$, $1{\mu}M$, $1.5{\mu}M$ 농도별로 코팅한 것을 실험군으로 하였다. 티타늄 디스크 표면에 분사된 복합체가 submicron입자 크기로 이루어졌는지SEM을 통해 확인하였으며, MS275로 코팅한 디스크와 양극산화 디스크의 거칠기 차이를 확인하기 위해 AFM으로 관찰하였다. 디스크 위에 간엽줄기세포 배양 후 1, 4, 7일에 세포증식 양상을 SEM과 MTT 검사를 통해 확인하였다. 결과: AFM (atomic force microscope) 결과 대조군과 실험군에서 거칠기의 유의할만한 차이가 없었다(P>.05). MTT 결과 1, 4, 7일 시간이 지남에 따라 세포 증식이 활발해졌으며 세포배양 7일에 $0.5{\mu}M-1.5{\mu}M$ MS275 농도 안에서, MS275의 농도가 커짐에 따라 세포의 활성도가 높아짐이 유의할 수준으로 확인되었다(P<.05). 세포 부착을 SEM으로 확인한 결과, 세포의 부착 수는 시간이 갈수록 증가하고 부착 형태 역시 돌기가 크고 넓어지며, 표면과 긴밀함 접촉이 증가하였다. 결론: FE-SEM과 MTT 결과 MS275/PLGA 복합체로 표면 처리된 타이타늄 표면에서 세포가 초기에 (7일내) 빠르게 증식하였다. 또한 복합체 처리군의 농도가 증가할수록 높은 세포 성장 수치를 보였다.