• Title/Summary/Keyword: electronic eye

검색결과 183건 처리시간 0.019초

Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP (최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성)

  • Shin, Seok-Hyun;Hwang, Do-Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.67-75
    • /
    • 2012
  • Purpose : We studied enhanced method to view the vessels in the brain using Magnetic Resonance Angiography (MRA). Noticing that Maximum Intensity Projection (MIP) image is often used to evaluate the arteries of the neck and brain, we propose a new method for view brain vessels to stereo image in 3D space with more superior and more correct compared with conventional method. Materials and Methods: We use 3T Siemens Tim Trio MRI scanner with 4 channel head coil and get a 3D MRA brain data by fixing volunteers head and radiating Phase Contrast pulse sequence. MRA brain data is 3D rotated according to the view angle of each eyes. Optimal view angle (projection angle) is determined by the distance between eye and center of the data. Newly acquired MRA data are projected along with the projection line and display only the highest values. Each left and right view MIP image is integrated through anaglyph imaging method and optimal stereoscopic MIP image is acquired. Results: Result image shows that proposed method let enable to view MIP image at any direction of MRA data that is impossible to the conventional method. Moreover, considering disparity and distance from viewer to center of MRA data at spherical coordinates, we can get more realistic stereo image. In conclusion, we can get optimal stereoscopic images according to the position that viewers want to see and distance between viewer and MRA data. Conclusion: Proposed method overcome problems of conventional method that shows only specific projected image (z-axis projection) and give optimal depth information by converting mono MIP image to stereoscopic image considering viewers position. And can display any view of MRA data at spherical coordinates. If the optimization algorithm and parallel processing is applied, it may give useful medical information for diagnosis and treatment planning in real-time.

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.

Training Program to Raise Consciousness Among Adolescents for Protection Against Skin Cancer through Performance of Skin Self Examination

  • Balyaci, Ozum Erkin;Kostu, Nazan;Temel, Ayla Bayik
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권10호
    • /
    • pp.5011-5017
    • /
    • 2012
  • Background: Overexposure to sunlight in childhood and the adolescent period and associsated sunburns significantly increase the risk of skin cancer in adulthood. In Turkey, the incidence of skin cancer in the general population is 0.8%. The incidence is 0.6% and the mortality rate is 0.4% for men, while these rates are 1.0% and 0.7%, respectively, for women. If skin cancer is found early, its treatment is facilitated. Therefore, personal skin examination is important for early diagnosis. Objectives: Our aim was to determine the effects of training for raising consciousness among adolescents to protect against skin cancer by influencing skin self examination behavior. Method: This quasi experimental intervention study was conducted between February and April 2012 in Izmir. The study population consisted of students attending $6^{th}$, $7^{th}$ and $8^{th}$ classes of a primary school (n:302). No sampling was performed. Data were collected with a form developed by the researchers based on the literature. The first part of form is aimed to determine demographic characteristics of adolescents (3 questions) and their risk status of skin cancer (6 questions). The second part was prepared for skin cancer risks of adolescents (8 questions) and indications of skin cancer (12 questions). The last part was intended to determine their knowledge about skin self examination (4 questions) and behavioral stages of skin self examination (1 question). Data collection was achieved with a questionnaire form in three phases. In the 1st phase, data about demographic characteristics of students, risk status of skin cancer, knowledge level of skin cancer and behavior stages were collected. In the $2^{nd}$ phase, skin self examination training based on the transtheoretical model was performed within the same day just after obtaining preliminary data. In the $3^{rd}$ phase, adolescents were followed up three times to establish the efficacy of the training (on the $15^{th}$ day after training program and at end of the $1^{st}$ and $2^{nd}$ months). Follow-up data were evaluated by questioning skin self examination performing behavior stages through electronic mail. Results: Half of the adolescents (50.5%) are male, and 58.4% of them are 13 years old with a mean age of $12{\pm}1.15$ years. About 29.4% of adolescents had brown hair color, 37.9% had brown/hazel eye color, 29.4% had white skin, and 47.2% had fewer than 10 moles in their body. The pretest mean score on knowledge level about risks of skin cancer was found to be $4.19{\pm}1.96$, while the post-test mean score was $6.79{\pm}1.67$ (min:0, max:8).The pretest mean score about indications of skin cancer was $7.45{\pm}3.76$, while the post-test mean score was $10.7{\pm}2.60$ (min:0, max:12). The increases were statistically significant (p<0.05). The behavior "I do not perform skin self examination regularly in every month and I do not think to perform it in the next 6 months" was reduced from 52.8 to 35.5% after training. Conclusion: The training program organized to raise consciousness among adolescents for protection against skin cancer increased the knowledge level about risks and indications of skin cancer and it also improved the behavior of performing skin self examination.