• Title/Summary/Keyword: electronic equipment

Search Result 1,556, Processing Time 0.03 seconds

Implementation of Capacitance Measurement Equipment for Fault Diagnosis of Multi-channel Ultrasonic Probe (다중채널 초음파 프로브 고장진단을 위한 커패시턴스 측정 장치 구현)

  • Kang, Bub-Joo;Kim, Yang-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.175-184
    • /
    • 2016
  • In this paper, we propose the method to measure the capacitances using not LCR meter but capacitance to voltage(C/V) conversion. And we design the analog MUX circuits that convert 192 channels to 6 MUX channels in order to implement the diagnosis of multi-channel ultrasonic probe. This paper derives the conversion function that converts the digital voltage of each MUX channel to the capacitance using the least squares method because the circuit characteristics that convert the voltage of each MUX channel to the capacitance are different. The developed prototype illustrates the performance test results that the measure times are measured by within 4sec and the measure error rates of maximum, minimum, and average values are within 5% in terms of the repeated measurements of all 192 channels.

A Study on the Analysis Method of Tracking Process using Voltage Waveforms (전압파형을 이용한 트래킹 진전과정 분석방법에 관한 연구)

  • Jee, Sung-Wook;Lee, Chun-Ha;Yoon, Dae-Hee;Song, Hyun-Jik;Shim, Kwang-Yul;Park, Won-Ju;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.30-35
    • /
    • 2006
  • Voltage is generally and exactly measured in the electric and electronic field. So, we studied method for detecting electric equipment faulty state using only electric voltage. It is called the Partition-FFT. Tracking is simulated by method and tester proceed on IEC 60112. We analyze voltage waveforms by tracking tester with Partition-FFT. As the result tracking process is clearly distinguished by 6 steps. Tracking is one of the major reason of electric accidents. The Partition-FFT is using a digital oscilloscope and a computer software. If Partition-FFT analysis is applied to the electricity facilities, We can prevent from happenning electric accidents cause of tacking breakdown with low prices and easy measurment. Most of all, Partition-FFT is system that make a visual tacking process. So, everyone is able to detect to possibility of electric accidents.

A Study on Harmonics Analysis and Modelling for Distribution System (배전 시스템의 고조파 분석 및 모델링에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Jeong, Dong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.62-68
    • /
    • 2007
  • The increasing use of power electronic equipment in distribution system has been the reason for the greater concern about a harmonic in recent time. Therefore, it is necessary for measurement and modelling to analyze a harmonic level and a transfer characteristic in distribution system. In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000-3-6. Harmonic voltage and orient were measured at the PCC of real distribution system Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current under steady-state. Harmonic transfer characteristic were investigated through a analysis of harmonic voltage and current under harmonic current source.

Contents characteristics of polybrominated diphenyl ethers (PBDEs) in indoor household dust (실내 먼지 중 브롬화난연제 함유특성 연구)

  • Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.113-119
    • /
    • 2013
  • The objective of this study was to understand the content characteristic of polybrominated biphenyl ethers in indoor household dust. Polybrominated diphenyl ethers (PBDEs) are widely used as additive brominated flame retardants (BFR) in electrical and electronic equipment, and insulation in the indoor environment, and may be released indoors via volatilization or as dusts. The indoor household dust samples were collected from January to December in 2011 and measured for the concentrations, congener profiles and possible sources of PBDEs. The concentrations of 22 congeners of PBDEs (the sum of PBDEs 47, 49, 66, 71, 77, 85, 99, 100, 119, 126, 138, 153, 154, 156, 183, 184, 191, 196, 197, 206, 207 and 209) were 35.22~575.88 ng/g for apartment dust samples and 524.44 ng/g for laboratory dust sample. The eight congeners of BDE-47, 153, 183, 196, 197, 206, 207, and 209 are detected in the more than 1 ng/g. The three congeners of BDE-206, 207 and 209 in all dust samples were detected.

Method for Identifying Lava Tubes Among Pit Craters Using Brightness Profile Across Pits on the Moon or Mars

  • Jung, Jongil;Hong, Ik-Seon;Cho, Eunjin;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Caves can serve as major outposts for future human exploration of the Moon and Mars. In addition, caves can protect people and electronic equipment from external hazards such as cosmic ray radiation and meteorites impacts and serve as a shelter. Numerous pit craters have been discovered on the Moon and Mars and are potential entrances to caves; the principal topographic features of pit craters are their visible internal floors and pits with vertical walls. We have devised two topographical models for investigating the relationship between the topographical characteristics and the inner void of pit craters. One of our models is a concave floor void model and the other is a convex floor tube model. For each model, optical photographs have been obtained under conditions similar to those in which optical photographs have been acquired for craters on the Moon and Mars. Brightness profiles were analyzed for determining the profile patterns of the void pit craters. The profile patterns were compared to the brightness profiles of Martian pit craters, because no good-quality images of lunar pit craters were available. In future studies, the model profile patterns will be compared to those of lunar pit craters, and the proposed method will likely become useful for finding lunar caves and consequently for planning lunar bases for manned lunar expeditions.

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital (종합병원 진단용방사선장비의 고장유형 분석)

  • Lee, Woo-Cheul;Kim, Jeong-Lae
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF

Design for a Medical Devices Safety Information Reporting System for the Hospitals (의료기기 안전성 정보 원내 보고 시스템 설계)

  • Jang, Hye Jung;Choi, Young Deuk;Kim, Nam Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.140-147
    • /
    • 2015
  • In this study, medical devices safety information reporting system was designed to manage medical devices for the efficient management of in-hospital adverse events. The current management of medical device adverse event reporting regulations and the legal status of the system and procedures for identifying the system were reviewed. MSF/CD(Microsoft Solution Framework/Component Design) was applied to the system design. Through this study, we can understand medical devices management including the notice provisions of the Ministry of Food and Drug Safety for medical devices safety information reporting. We also expect this study will help to improve patient safety and the effective management of medical equipment, and contribute to activating medical devices safety information reporting.

Bicycle Accident Position Tracing and Alarm System (자전거 사고 위치 추적 및 알림 시스템)

  • Kim, Jang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.93-98
    • /
    • 2014
  • Bicycle accidents increase as the number of people riding bicycles increases following the trend try to enhance health and looking for alternative energy sources in the era of high oil price. In bicycle accident cases, physical risk is higher because the impact of the accident has a direct effect on the body of the rider. Therefore, the bicycle rider in an accident might unable to report the accident by themselves, thus, unable to quickly respond to the accident situation. This study developed a system for informing bicycle accidents upon bicycle accident by reporting and texting the accident location using a smart phone application after identifying the accident location using a GPS equipment based on the signal that senses the accident through the system installed in the bicycle for the purpose to improve bicycle riders' safety. This study confirmed the effectiveness of the system developed to quickly respond to the accident to prevent secondary damage through an experiment.

The danger and vulnerability of eavesdropping by using loud-speakers (스피커를 이용한 도청 위험에 대한 연구)

  • Lee, Seung Joon;Ha, Young Mok;Jo, Hyun Ju;Yoon, Ji Won
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.6
    • /
    • pp.1157-1167
    • /
    • 2013
  • The development of electronic devices has recently led to many problems such as personal information rape and leakage of business information. Conventional loud-speakers have been generally used to output devices. It can be, however, operated as a micro-phone which was abused as a means for eavesdropping since the speaker and microphone have basically the equivalent structure. Most importantly, the general peoples are not aware of the approaching danger about using speaker as microphone. And, traditional eavesdropping detection equipment does not check the attack. In this paper, we demonstrate that there is a serious danger and vulnerability in using loud-speakers since they can be used as eavesdropping devices.