• 제목/요약/키워드: electronic devices

검색결과 4,503건 처리시간 0.049초

Amino-style 유도체를 이용한 분자 전자 소자의 전류-전압 특성에 관한 연구 (Current-Voltage Characteristics of Molecular Electronic Devices Using a Amino-Style Derivatives)

  • 김소영;구자룡;김영관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.882-885
    • /
    • 2004
  • Organic molecules have many properties that make them attractive for electronic applications. We have been examining the progress of memory cell by using molecular-scale switch to give an example of the application using both nanoscale components and Si-technology. In this study, molecular electronic devices were fabricated with amion style derivatives as redox-active component to compare to the devices using Zn-Porphyrin derivatives. This molecule is amphiphilic to allow monolayer formation by the Langmuir-Blodgett (LB) method, and then this LB monolayer is inserted between two metal electrodes. According to current-voltage (I-V) characteristics, it was found that the devices show remarkable hysteresis behavior and can be used as memory devices at ambient conditions, when aluminum oxide layer was existed on bottom electrode. Diode-like characteristics were measured only, when Pt layer was existed as bottom electrode. It was also found that this metal layer interacts with the organic molecules and acts as a protecting layer, when thin Ti layer was inserted between the organic molecular layer and the top Al electrode. These electrical properties of the devices may be applicable to active components for the memory and/or logic gates in the future.

  • PDF

Schottky Barrier MOSFETs with High Current Drivability for Nano-regime Applications

  • Jang, Moon-Gyu;Kim, Yark-Yeon;Jun, Myung-Sim;Choi, Chel-Jong;Kim, Tae-Youb;Park, Byoung-Chul;Lee, Seong-Jae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권1호
    • /
    • pp.10-15
    • /
    • 2006
  • Various sizes of erbium/platinum silicided n/p-type Schottky barrier metal-oxide-semiconductor field effect transistors (SB-MOSFETs) are manufactured from $20{\mu}m$ to 10nm. The manufactured SB-MOSFETs show excellent DIBL and subthreshold swing characteristics due to the existence of Schottky barrier between source and channel. It is found that the minimization of trap density between silicide and silicon interface and the reduction of the underlap resistance are the key factors for the improvement of short channel characteristics. The manufactured 10 nm n-type SBMOSFET showed $550{\mu}A/um$ saturation current at $V_{GS}-V_T$ = $V_{DS}$ = 2V condition ($T_{ox}$ = 5nm) with excellent short channel characteristics, which is the highest current level compared with reported data.

Vacuum Packaging and Operating Properties of Micro-Tunneling Sensors

  • Park, H.W.;Lee, D.J.;Son, Y. B.;Park, J.H.;Oh, M. H.;Ju, B. K.
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.110-110
    • /
    • 2000
  • Cantilever-shaped lateral field emitters were fabricated and their electrical characteristics were tested. As shown in Fig.1, poly-silicon cantilevers were fabricated by the surface micromachining and they were used to the vacuum magnetic field sensors. The tunneling devices were vacuum sealed with the tubeless packaging method, as shown in Fig.2 and Fig.3. The soda-lime glasses were used for better encapsulation, so the sputtered silicon and the glass layers on the soda-lime glasses were bonded together at 1x10$^{-6}$ Torr. The getter was activated after the vacuum sealing fur the stable emissions. The devices were tested outside of the vacuum chamber. Through vacuum packaging, the tunneling sensors can be utilized. Fig.4 shows that the sensor operates with the switching of the magnetic field. When the magnetic field was applied to the device, the anode currents were varied by the Lorentz force. The difference of anode currents can be varied with the strength of the applied magnetic field.

  • PDF

이식형 전자의료기 연구동향과 기술개발의 과제 (Research Trends and Challenges in Technology Development of Medical Electronic Implant Devices)

  • 조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.415-430
    • /
    • 2008
  • The technologies in medical electronic implant(MEI) devices are developing rapidly, and already, there are various kinds of the MEI devices in the current medical equipments market. Recently, the global market scale of MEI devices have been increased about 13% year by year, and the import amount of MEI devices in Korea is increasing rapidly. In the near future, the demands of MEI devices will be magnificently increasing by the continuous development of the biomedical electronics devices which coupled with neural, brain and other organs will bring us to tremendous effects, such as providing new therapeutic solutions to patients, extension and saving human life, and an important clue of medical development. However, the investment of the research and the activity of developments in this field are still very weak in the Korea. Consequently, this paper introduces about the research trends of MEI devices, and technological problems those must be solved, and then concludes with the suggestions in order to be the leading country in this field.

AV 기기를 위한 AC 입력 전류 모니터링 대기 전력 저감 시스템 (Reducing Standby Power Consumption System by Monitoring the AC Input Current for the AV Devices)

  • 이대식;이강현
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1493-1496
    • /
    • 2016
  • This paper proposes a system for reducing the standby power consumption in using the consumer electronic devices such as a television, a home theater, a set-top box, or a DVD player. The system is consisted of a flyback converter, monitoring circuits, a relay and a micro-processor. The proposed system can reduce the standby power consumption by disconnecting the AC input and the consumer devices can be turned on with a remote control. The proposed standby power system consumes the low power to receive the infrared signal from the remote controller. Furthermore, a electronic double layer capacitor is used to store the energy with high efficiency. The proposed power system can operate the 플라이백 converter to charge the electronic double layer capacitor and connect the AC input to the consumer electronic devices. The proposed power circuit can reduce the standby power consumption in AV devices without increasing the cost. The prototype is implemented to verify the system with the commercialized products.

전자식체온계 기준규격 개발 연구 (Research of Developing of Standards for Electronic Thermometers)

  • 김은주;이민정;이병영;박기정;김동섭;이인수;박해대;정희교
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.

Mobile Devices Technologies: Risks and Security

  • Alsaqour, Raed;Alharthi, Sultan;Aldehaimi, Khalid;Abdelhaq, Maha
    • International Journal of Computer Science & Network Security
    • /
    • 제21권4호
    • /
    • pp.249-254
    • /
    • 2021
  • Our society is depending on mobile devices that play a major role in our lives. Utilizing these devices is possible due to their speed power and efficiency in performing basic as well as sophisticated operations that can be found in traditional computers like desktop workstations. The challenge with using mobile devices is that organizations are concerned with the interference between personal and corporate use due to Bring Your Own Device (BYOD) trend. This paper highlights the importance of mobile devices in our daily tasks and the associated risks involved with using these devices. Several technologies and countermeasures are reviewed in this paper to secure the mobile devices from different attempts of attacks. It is important to mention that this paper focuses on technical measures rather than considering different aspects of security measures as recommended by the cybersecurity community.

Novel Devices for Sub-100 nm CMOS Technology

  • Lee, Jong-Ho
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.180-183
    • /
    • 2000
  • Beginning with a brief introduction on near 100 nm or below CMOS devices, this paper addresses novel devices for future sub-100 nm CMOS. First, key issues such as gate materials, gate dielectric, source/drain, and channel in Si bulk CMOS devices are considered. CMOS devices with different channel doping and structure are introduced by explaining a figure of merit. Finally, novel device structures such as SOI, SiGe, and double-gate devices will be discussed for possible candidates for sub-100 nm CMOS.

  • PDF

전자의료기기용 소프트웨어의 신뢰성 평가 방법 (Reliability Evaluation Method of Software for Electronic Medical Devices)

  • 박순옥;양해술
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.758-767
    • /
    • 2007
  • 오늘날 의료기기는 내장된 소프트웨어에 의해 제어되는 전자 의료기기의 형태로 급격하게 발전하고 있다. 따라서 전자 의료기기의 품질은 내장된 의료용 소프트웨어의 품질에 의해 크게 좌우될 수밖에 없다. 특히, 의료기기가 인간의 생명과 밀접하게 연관되어 있다는 점을 고려할 때, 프로그램 가능한 전자 의료기기의 품질 측면에서도 신뢰성 측면을 특히 고려한 평가 방법이 연구되어야 할 것으로 생각된다. 본 논문에서는 소프트웨어 제품평가에 관련된 국제표준인 ISO/IEC 9126과 ISO/IEC 12119를 기반으로 하여 국내의 프로그램 가능한 전자 의료기기의 특성을 고려하여 신뢰성에 대한 평가를 위한 방법을 구축하고 아울러 신뢰성 평가 방법인 FMEA 기법을 적용할 수 있는 체계를 구축하였다.

  • PDF