• 제목/요약/키워드: electromagnetic transient

검색결과 288건 처리시간 0.024초

가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석 (EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear)

  • 정영환;이동수;김정배;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구 (A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter)

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1211-1217
    • /
    • 2007
  • In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

HVDC 단에 연결된 동기기의 여자시스템 스트레스 (Excitation System Stress in Synchronous Machine Connected to HVDC System)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

지중 송전 케이블의 편단접지 시스템에서의 계통 보호 방안 (Application of Protecting Methods for Single Point Bonding on Underground Transmission Cable)

  • 하체웅;김정년;이인호;김종철;이광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.15-17
    • /
    • 2005
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-line which is connected with overhead line and underground cable. This paper investigates the failure of SVL(Sheath Voltage Limiter) and presents the application of protection methods for single point bonding on underground transmission cable system. EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as, underground cables, SVLs and towers.

  • PDF

초고압 GIS 접지시스템에서 낙뢰 및 고장에 의한 과도특성 해석 (Transient Characteristics of GIS Grounding Systems by Lightning and Fault)

  • 이형수;심건보;김정훈;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.77-79
    • /
    • 1995
  • In performing lightning and fault studies in GISs, it is of great importance to accurately model the conductor network consisting of the grounding systems and overhead conductor structures. In particular, the overhead grounded pipe enclosures of the GIS should be appropriately modelled. In this paper, the overhead pipe enclosures of a 500 kV $SF_6$ breaker and substation grounding system are presented in detail. During a phase-to-ground fault, scalar potentials and electromagnetic fields are computed at different frequencies for various conductor network configurations is defined by varying the number of conductors used to represent the pipes at different frequencies are obtained. Such knowledge will be very useful in reducing computation time for a transient ground potential rise study which will be performed in the future.

  • PDF

유도가열 조리기기용 인버터 파라미터 최적화에 관한 연구 (A Study on the Parameter Optimization of Inverter for Induction Heating Cooking Appliance)

  • 강병관;이세민;박정욱
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.77-85
    • /
    • 2009
  • With the advent of power semiconductor switching devices, power electronics relating to high frequency electromagnetic eddy current based induction heating technology have become more suitable and acceptable. This paper presents high-frequency induction heating cooking appliance circuit based on the zero current switching-PWM single ended push-pull(ZCS-PWM SEPP) resonant inverter added AC-DC converter. This inverter uses pulse-width-modulation(PWM) control method with active auxiliary quasi-resonant lossless inductor snubbers and a switched capacitor. To improved the transient performance, the PI controller is applied for this system. For the systematic parameter optimization of the PI controller, the gradient-based optimization algorithm is applied. The performance of optimized parameters is evaluated using simulation and experimental test. These results show that the proposed systematic optimal tuning method improve the transient performances of this system.

초전도 한류기 투입 위치에 따른 TRV 영향 분석 (Analysis of a TRV influence according to application position of a SFCL)

  • 방승현;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.91-92
    • /
    • 2008
  • The rating of a circuit breaker depends not only on the interrupting current but also on a transient recovery voltage (TRV). To achieve a successful interruption, the circuit breaker must withstand the TRV. A superconducting fault current limiter (SFCL) is a device that limits the fault current fast and effectively without having high impedance during normal operation of the power system. Therefore, we studied the influence of the TRV according to the application of a resistive type SFCL in distribution system. This paper analyses the influence of the TRV for various application position of the resistive SFCL. The distribution system and the resistive SFCL were modeled by using EMTP-RV (Electromagnetic Transient Program - Restructured Version)

  • PDF

풍력발전시스템의 배전계통 연계운전 시 전의품질 해석 (Power Quality Analysis of Wind Power System Embedded in Distribution Networks)

  • 김응상;노병권;추진부;장병태;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.229-231
    • /
    • 1999
  • This paper deals with electromagnetic transient modelling of wind power system embedded in distribution networks. Wind power system consists of induction generator link reactor, distribution line, and controlled load unit. The introduction of embedded wind power system presents a new set of conditions to networks both with respect to power quantify needed to be transported and power quality such as sag swell, very short interruption, and flicker. This paper investigates the transient behavior of voltage, frequency, and load flow in wind driven induction generation system embedded in distribution networks.

  • PDF

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책 (The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines)

  • 하체웅;김정년;이수길;허회덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF