• 제목/요약/키워드: electroencephalographic (EEG)

검색결과 51건 처리시간 0.026초

Emotion Recognition Method for Driver Services

  • Kim, Ho-Duck;Sim, Kwee-Bo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제7권4호
    • /
    • pp.256-261
    • /
    • 2007
  • Electroencephalographic(EEG) is used to record activities of human brain in the area of psychology for many years. As technology developed, neural basis of functional areas of emotion processing is revealed gradually. So we measure fundamental areas of human brain that controls emotion of human by using EEG. Hands gestures such as shaking and head gesture such as nodding are often used as human body languages for communication with each other, and their recognition is important that it is a useful communication medium between human and computers. Research methods about gesture recognition are used of computer vision. Many researchers study Emotion Recognition method which uses one of EEG signals and Gestures in the existing research. In this paper, we use together EEG signals and Gestures for Emotion Recognition of human. And we select the driver emotion as a specific target. The experimental result shows that using of both EEG signals and gestures gets high recognition rates better than using EEG signals or gestures. Both EEG signals and gestures use Interactive Feature Selection(IFS) for the feature selection whose method is based on the reinforcement learning.

알코올 의존 환자군의 뇌파 특성 : 3차원적 신호원 국소화 (Electroencephalographic Characteristics of Alcohol Dependent Patients : 3-Dimensional Source Localization)

  • 서상철;임성진;이상구;신철진
    • 생물정신의학
    • /
    • 제22권2호
    • /
    • pp.87-94
    • /
    • 2015
  • Objectives The power spectral analysis of electroencephalogram has been widely used to reveal the pathophysiology of the alcoholic brain. However, the results were not consistent and the three dimensional study can be hardly found. The purpose of this study was to investigate characteristics of the three dimensional electroencephalographic (EEG) activity of alcohol dependent patients using standardized low resolution electromagnetic tomography (sLORETA). Methods The participants consisted of 30 alcohol dependent patients and 30 normal healthy controls. All the participants were males who had refrained from alcohol at least one month and were not taking any medications. Thirty two channel EEG data was collected in the resting state with eyes-closed condition during 30 seconds. The three dimensional data was compared between two groups using sLORETA for delta, theta, alpha, beta1, beta2, and beta3 frequency bands. Results sLORETA revealed significantly increased brain cortical activity in alpha, beta1, beta2, and beta3 bands each in alcohol dependent patients compared to normal controls. The voxels showing the maximum significance were in the left transverse temporal gyrus, left superior temporal gyrus, left anterior cingulate, and left fusiform gyrus in alpha, beta1, beta2, and beta3 bands respectively. Conclusions These results suggest that chronic alcohol intake may cause neurophysiological changes in cerebral activity. Therefore, the measuring of EEG can be helpful in understanding the pathophysiology of cognitive impairements in alcohol dependence.

Electroencephalographic Correlation Dimension Changes with Depth of Halothane

  • Lee, Maan-Gee;Park, Eun-Ju;Choi, Jung-Mee;Yoon, Moon-Han
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권5호
    • /
    • pp.491-499
    • /
    • 1999
  • This study was designed to evaluate the efficacy of dynamic parameters, such as correlation dimension $D_2,$ by comparing spectral electroencephalographic (EEG) parameters. These parameters are used to estimate the depth of halothane anesthesia as defined by the presence of body movement in response to a tail clamp. Six rats were used and each of them was exposed to halothane sequentially at the concentrations of 0%, 0.5%, 1.0% and 1.5% for 30 min. A tail clamp was applied every five min and the movements were recorded at each concentration level. The spectral parameters and the dynamic parameters were derived from 20-sec and 10-sec segments, respectively, from the last 5-mins of EEG recording at each concentration level. Correlation coefficients between the parameters and the movements were calculated. Standardized values of three parameters, betaL power, median power frequency (MPF), and $D_2$ were derived by calculation based on the number of animals showing the movement in response to a tail clamp. The betaL power had the largest correlation coefficient to spontaneous movement and to the response to a tail clamp than any other band parameter. MPF had a better correlation with the movement than 90% spectral edge frequency. Among the dynamic parameters, $D_2$ on the parietal cortex had a better correlation with the movement. The level of deviation and variation of standardized $D_2,$ MPF, and betaL were significant (p<0.01). The order of deviation and variation was; betaL power > MPF > $D_2.$ The correlation dimension serves as a better index for the depth of halothane anesthesia defined in forms of a response to external stimulation.

  • PDF

청각자극에 따른 세타파와 알파파의 스펙트럼적 반응 (Spectral Perturbation of Theta and Alpha Wave for the Affective Auditory Stimuli)

  • ;이효종
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권10호
    • /
    • pp.451-456
    • /
    • 2014
  • 감정을 유발하는 청각자극에 따라 발생되는 EEG(Electroencephalographic) 스펙트럼 강도와 감정 반응 간의 상관관계는 중요한 변수이다. 약 20여 년 전 쾌감을 주는 청각자극에 대하여 측정된 신호의 강도가 전전두엽에서 비대칭적으로 반응을 보였다는 연구 결과가 발표되었다. 본 연구에서는 자극관련 스펙트럼적 반응(Event-related Spectral Perturbation: ERSP)이 전두엽에서 비대칭적으로 발생되는지 고찰하기 위하여 청각자극 실험을 수행하였다. 30명의 건강한 대학생 지원자들이 IADS(International Affective Digital Sounds) 실험에 참여하였다. 이 청각자극은 행복, 공포, 그리고 중립의 3단계로 분류되었으며, 데이터의 분석은 세타파(4-8Hz)와 알파파(8-13Hz)에서 이루어졌다. 알파대역의 ERSP 지도는 오른쪽 전두엽에서 행복감과 공포감의 자극에서 높은 신호의 강도를 보여주는 반면 중립성 자극에서는 왼쪽 전두엽에서 높은 신호가 발생되었다. 그러나 세타파는 행복감과 공포감의 자극에 따라 좌측 전두엽에서 높은 신호가 나타나는 반면, 중립적 자극에 따라 우측 전두엽에서 높은 신호를 보여주었다. 높은 쾌감성 자극(행복)은 상대적으로 우측 전두엽에서 높은 EEG 신호가 측정되었으며, 낮은 쾌감성 자극(중립과 공포)은 왼쪽 전두엽에서 측정되었다. 또한 가장 큰 세타파의 변화가 전두엽의 중앙에서 발생되었다. 알파파에서 행복한 청각자극에 가장 강한 신호가 전두엽 전체에서 관찰되었다. 이 결과들은 기존의 감정들과 일치되며, 세타파와 알파파가 감정처리에서 중요한 역할을 하고 있음을 시사한다.

Electroencephalographic Effects of Chlorpromazine in Rats

  • Yun, Jeong-E;Lee, Maan-Gee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제3권3호
    • /
    • pp.245-250
    • /
    • 1999
  • The effects of an antipsychotic, chlorpromazine, on the electroencephalogram (EEG) were observed while rats were awake but immobile. The time course and the dose-dependency of the EEG changes were examined. The method of the power spectrum analysis was used to examine the EEG changes by the drug. The bands were divided into delta $(1{\sim}3.5\;Hz),$ theta $(3.5{\sim}8\;Hz),$ alpha $(8{\sim}13\;Hz),$ beta1 $(13{\sim}21\;Hz),$ beta2 $(21{\sim}30\;Hz)$ and gamma $(30{\sim}50\;Hz).$ In rats, the low dose of chlropromazine (1 mg/kg, i.p.) produced a significant increase in the power of the beta1 band. The higher doses (5, 10 mg/kg, i.p.) produced a significant increase in the power of the delta, theta, alpha and beta1 bands, and the decrease in the power of the gamma band. The powers of the bands changed dose-dependently. Then, the authors discussed whether the EEG effects produced by a drug are associated with the accompanying behavioral changes specifically.

  • PDF

EEG Fast Beta Sub-band Power and Frontal Alpha Asymmetry under Cognitive Stress

  • Sohn, Jin-Hun;Park, Mi-Kyung;Park, Ji-Yeon;Lee, Kyung-Hwa
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2001
  • Intensity of background noise is a factor significantly affecting both subjective evaluation of experienced stress level and associated electroencephalographic (EEG) responses during mental load in noisy environments. In the study on 27 subjects we analyzed the influence of the background white noise (WN) intensity on psychophysiological responses during a word recognition test. Electrocortical activity were recorded during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different intensities of background WN (55, 70 and 85 dB).. An important finding in terms of physiological reactivity was similarity of all physiological response profiles between 55 and 70dB WN, i.e., none of physiological variables differentiated the two conditions, while 85dB WN resulted in a significantly different profile of reactions (higher fast beta power in EEG spectra). This condition was characterized by highest subjective rating of experienced stress, had more fast beta activity and had tendency of right hemisphere dominance, emphasizing the role of brain lateralization in negative affect control.

Frontal Asymmetry Analysis of Theta Wave in the Audio Emotional Experiment Revealed by Event-related Spectral Perturbation

  • Du, Ruoyu;Lee, Hyo Jong
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 춘계학술발표대회
    • /
    • pp.992-994
    • /
    • 2014
  • Hemispheric asymmetry in prefrontal activation have been proposed in two decades ago, as measured by electroencephalographic (EEG) power in the theta band (4-8Hz), is related to reactivity to affectively pleasure audio stimuli. In this study, we designed an emotional audio stimulus experiment in order to verify frontal EEG asymmetry by analyzing ERSP results. Thirty healthy college students volunteered the stimulus experiment with the standard IADS affective sounds. These affective sound clips are classified in three emotion states, happy, neutral and fear. ERSP image results revealed that there are the stronger responses of high arousal (fear and happy) in the left prefrontal lobe, while the stronger responses of low arousal (neutral) in the right pre-frontal lobe. However, the high pleasure emotions (happy) can elicit greater relative right EEG activity, while the low and middle pleasure emotions (fear and neutral) can elicit the greater relative left EEG activity. Additionally, the most response differences of theta band have been found out in the medial frontal lobe, which is proved as the frontal midline theta.

멀티레이터 샘플링 문제로서의 뇌파신호 디스플레이 (EEG signal display as a multirate sampling problem)

  • 최한고;오영석;이상재
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.311-314
    • /
    • 1996
  • The display of biological signals in monitors often involves a multirate sampling operation which consists of decimation and intenolation. All electroencephalographic (EEG) samples of 10 to 30 seconds must be displayed in the computer screen to keep the aspect ratio of the paper polygraph output. Since the current affordable display technology plots at most 2,000 pixels per row, some samples need to be discarded. This paper studies methods to perform this operation characterizing them from the signal processing viewpoint and compares the display quality among several decimations. Experimental results show that a nonlinear operation such as the peak detection could be preferable than the canonical linear filtering to reduce aliasing.

  • PDF

조류기인 유기물질의 제브라피쉬에 대한 뇌파측정기반 독성평가 (Electroencephalography (EEG) based Toxicity Test of Algae Organic Matter on Zebrafish)

  • 오세현;장형준;조윤철
    • 한국물환경학회지
    • /
    • 제39권3호
    • /
    • pp.223-230
    • /
    • 2023
  • Harmful algae blooms have become a serious environmental problem in major river basins in Korea. They are known to produce various algal organic matters (AOMs) including intracellular organic matters (IOMs) and extracellular organic matters (EOMs). Generally AOMs cannot be easily removed by coagulation/flocculation process in conventional drinking water plants. AOMs produced by blue-green algae also include various toxins such as Microcystins, Anatoxin-a, and Saxitoxin known to have harmful effects on living organisms in aquatic environment. In this study, toxic effects of EOMs produced by three different algae species (Microcystis sp., Anabaena sp., and Oscillatoria sp.) on zebrafish were investigated using electroencephalography (EEG) recording method, a technology for recording brain activity. Electroencephalographic changes in zebrafish revealed that a low EOM had a negative effect on zebrafish compared to both Anabaena sp. and Oscillatoria sp. at 30 ppm EOM exposures. This result might be due to Microcystins present in EOMs produced by Microcystis sp. As a result of power spectrum density anallysis, exposure to EOMs produced by Microcystis sp. caused a state of vigilance in zebrafish. This EEG based toxicity test can be used to examine effects of harmful materials at low levels on living organisms in an aquatic system.

신생아 뇌파의 진단적 유용성에 대한 연구 (Diagnostic Significance of Neonatal Electroencephalography)

  • 김병의;김흥동
    • Clinical and Experimental Pediatrics
    • /
    • 제46권2호
    • /
    • pp.137-142
    • /
    • 2003
  • 목 적 : 신생아기의 뇌파검사가 대뇌질환에 얼마나 예민한 검사인가를 조사하고, 초음파 검사와 비교하여 얼마나 예민하고 특이도가 높은 검사 방법인지를 조사하였다. 그리고 뇌파검사가 신생아의 신경학적 예후를 평가하는데 얼마나 가치가 있는지를 조사하기 위하여 본 연구를 시행하였다. 방 법 : 신경계 질환의 기능평가를 위하여 뇌파검사를 시행한 87명의 신생아를 대상으로 하였으며 출생 후 3일 이내에 뇌파검사를 시행하였다. 출생 후 3일 이내에 시행한 초기 뇌 초음파검사 소견을 7일 이후에 시행한 자기공명영상검사 또는 초음파검사 소견과 비교하였다. 결 과: 뇌파 검사는 신생아의 뇌손상을 진단하는데 초음파 검사보다 높은 감수성과 특이성을 보이는 것으로 나타났다. 신경학적 예후에 대한 뇌파 소견의 감수성은 경증의 장애에 대해서는 91.7%, 중등도 이상의 장애에 대해서는 100.0%로 나타났으나, 초기 초음파 소견은 각각 20.8%, 18.8%로 나타났다. 결 론 : 뇌파검사는 신생아의 뇌손상을 진단하는데 민감한 검사이고, 후기 신경학적 예후를 예측하는데 유용한 검사로 사료된다.