• 제목/요약/키워드: electrodermal meridian measurement

검색결과 3건 처리시간 0.016초

경락노선상 피부전기 측정기 (EAV, MIR-1) 의 신뢰도 연구 (Reliability of Two Electrodermal Meridian Measurement Systems: EAV and Newly Developed MIR-1)

  • 인창식;허익범;이유정;사공석진;고형균;박영배;이우철
    • 대한한의진단학회지
    • /
    • 제9권1호
    • /
    • pp.125-130
    • /
    • 2005
  • Background and purpose: We evaluated the reliability of two electrodermal measurement devices on meridian skin areas; Electro Acupuncture according to Dr. Voll (EAV) method and newly developed MIR-1. Methods: Eighteen volunteers were tested repeatedly on the same condition with each device. To explore the intra-rater, inter-rater, and test-retest reliabilities, one rater tested each subject twice in succession, then the other rater tested the subject in a row. Finally, retests on the subjects with each device were performed 1 week later. The reliability was determined by Pearson correlation and intraclass correlation statistics. Results: EAV method showed poor reliability, while MIR-1 showed good reliability. Conclusion: It is suggested that further research on the reliability and useful device in both fields of clinical practice and biomedical research.

  • PDF

색채자극에 따른 심박변이도 변화와 한열조습변증의 상관성 (Variable Heart Rate Variability Measurements Induced by Wearing Color Glasses and Their Relationship with Hanyeol or Joseup Patterns of Korean Medicine Diagnostics, a Preliminary Observation)

  • 인창식;김선현;이능기;이우철;고형균;박영배;전세일
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.79-87
    • /
    • 2006
  • Objective : Biologic responses to color stimulation was observed and analyzed in relation with Korean medicine diagnostics. Methods : Twelve volunteers participated and completed the questionnaire on Hanyeol or Joseup patterns of Korean medicine diagnostics. Standard deviation of RR intervals (SDNN), an overall indicator of heart rate variability, was measured while wearing partially transparent acetate film glasses of various colors: (1) transparency or black, (2) red, green, or blue, or (3) cyan, or yellow. Results : Different responses to the color environmental stimulation were observed. Yeol pattern score was inversely related with the SDNN value under red color stimulation. Conclusion : This line of observations may serve as a basis of clinical application of color therapy, in particular, in relation with pattern diagnosis of Korean medicine, and may be applied in combination with existing electrodermal meridian measurement systems for better evaluation of Gi (life energy) phenomenon.

  • PDF

자궁근종환자의 피부저항 변이도에 관한 연구 (A Study on Skin Resistance Variability (SRV) of Women with Uterine Myoma)

  • 이향숙;손영주;정민영
    • 대한한의학회지
    • /
    • 제28권2호통권70호
    • /
    • pp.114-125
    • /
    • 2007
  • Objectives : Uterine myoma is the most common pelvic benign tumor and may cause abnormal menstrual pattern. The growth of uterine myoma depends on hormones. The 7-zone-diagnostic system (CP-6000A) is a measuring system using skin resistance variability (SRV). The machine shows organic energy and was reported by the gynecologic department to detect functional abnormality of hypothalamus-hypophysis-ovarian axis (H-P-O). Our study was to investigate the SRV of women with uterine myoma by the 7-zone diagnostic system. Methods: Two groups were selected from those who took the CP-6000A test in the College of Korean Medicine Hospital of Sangji University from March 2003 to September 2006. They were divided into normal control (n=40) and uterine myoma groups (n=40). Electrodermal activity of the two groups was compared. Results : The mean value of electrodermal activity of the uterine myoma group was lower than that of thenormal group in all areas on first and second measurement. Especially, the mean value of the patient group was significantly lower than that of the normal group and fell below normal range in the 1, 2, and 3 areas on first and second measurement. Conclusions : The results suggest that women with uterine myoma may have organic energy deficiency and functional abnormality of the H-P-O axis. Further studies to determine the feasibility of this 7 -zone diagnostic system as a reliable diagnostic tool are needed.

  • PDF