• 제목/요약/키워드: electrochemical potentiokinetic reactivation method(EPR)

검색결과 9건 처리시간 0.019초

재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가 (An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test)

  • 권일현;나성훈;송기욱;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

Double-loop electrochemical potentiokinetic reactivation 방법에 의한 Inconel 600의 예민화도 평가 (Evaluation on the sensitization degree for Inconel 600 by double-loop electrochemical potentiokinetic reactivation method)

  • 정광후;이정형;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.110-110
    • /
    • 2018
  • 여러 니켈합금 중 인코넬 600은 원전 가압경수로(PWR)의 튜브 재료로 널리 사용되는 재료이다. 스테인리스강과 비교하여 우수한 내식성과 기계적 특성으로 인해 화학설비, 발전설비, 그리고 해양설비 등과 같은 여러 산업분야에서도 널리 사용되고 있다. 그러나 가압경수로용 증기 발생기의 튜브 재료와 같은 특수 환경에서 예민화에 따른 입계부식 및 입계응력부식 등의 문제가 흔히 보고되고 있다. 이러한 내구성 문제는 설비 및 장비의 수명, 내구성 그리고 안정성 등의 치명적인 영향을 미친다. 따라서 용접, 열처리, 그리고 가공과정에서 발생하는 Inconel 600의 예민화 및 입계부식에 관한 연구가 활발히 진행되고 있다. 그러나 100시간 이상 장시간 열화된 시편에 대한 예민화 연구는 전무한 실정이다. 본 연구에서는 장시간 열화된 Inconel 600의 예민화를 평가하기 위해 최대 1,000시간까지 열화를 실시하였으며, 이에 대한 평가방법으로 Double-Loop Electrochemical Potentiokinetic Reactivation(DL-EPR) 시험법을 적용하였다. 본 실험에서 사용된 인코넬 600의 화학성분(wt, %)은 0.01 C, 0.05 Si, 0.14 Mn, 15.3 Cr, 0.5 Cu, 0.015 S, 그리고 나머지는 Ni 이다. 예민화 평가를 위한 등온 열화는 전기열처리로를 이용하여, $550^{\circ}C$$650^{\circ}C$에서 최대 1000시간까지 실시하였다. 열화에 따른 미세조직 변화는 scanning electron microscope와 energy dispersive x-ray spectroscopy를 이용하여 실시하였다. DL-EPR 실험은 $25^{\circ}C$의 0.1M $H_2SO_4$ + 0.001M KSCN(potasium thiocyanate) 수용액 하에서 실시하였으며, 분극은 OCP로부터 600 mV(SSE vs.)까지 1.67mV/s 주사속도로 forward scan을 실시 후, 동일한 속도로 OCP까지 reverse scan을 실시하였다. Degree Of Sensitization(DOS)값은 anodic scan peak($I_a$) 값과 reverse scan peak($I_r$) 값의 비로 산출하였다. $$i.e.\;DOS=I_r/I_a{\times}100$$. 그 결과, 온도 변수에 따른 Inconel 600강의 예민화 거동은 서로 상이한 경향을 나타내었다. $550^{\circ}C$의 경우, 열화가 진행됨에 따라 DOS값은 급격하게 증가하는 경향을 나타냈다. 반면, $650^{\circ}C$에서는 일정시간 이후부터 Cr 확산 현상에 의한 탈 예민화 현상이 관찰되었다.

  • PDF

304L 스테인리스강의 열처리에 따른 입계부식민감도 연구 (Sensitivity to Intergranular Corrosion According to Heat Treatment of 304L Stainless Steel)

  • 장형민;김동진;김홍표
    • Corrosion Science and Technology
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 2020
  • Even though 304 low-carbon (304L) stainless steel was developed to enhance the resistance to intergranular corrosion and stress corrosion cracking, it is occasionally subject to degradation in harsh environments. The degree of sensitization (DOS) of 304L stainless steel was studied as a function of sensitization using a double-loop electrochemical potentiokinetic reactivation (DL-EPR) method. Sensitizing heat treatment was performed in an Ar atmosphere at 500℃, 600℃, and 700℃, with heat treatment times varying from 0 to 96 h. DOS was measured by the ratio of the peak current density value of the forward scan to that of the reverse scan. After the EPR experiment, the specimen surface was observed by scanning electron microscopy and energy dispersive spectroscopy. The DOS of the specimens heat-treated at 600℃ increased with heat treatment times up to 48 h and then decreased due to a self healing effect. The DOS was higher in specimens heat-treated at 600℃ than those at 500℃ or 700℃. Corrosion of the sensitized specimens occurred mainly at the δ-γ phase boundary. The corrosion morphology at the δ-γ phase boundary changed with sensitizing heat-treatment conditions due to differences in chromium activity in γ austenite and δ ferrite.

Effects of Nb Content and Thermal History on the Mechanical and Corrosion Characteristics of Stainless Steels

  • Choe, Han-Cheol;Kim, Kwan-Hyu
    • Corrosion Science and Technology
    • /
    • 제2권3호
    • /
    • pp.117-126
    • /
    • 2003
  • Due to excellent corrosion resistance and mechanical properties, austenitic stainless steel is widely used as the material for chemical plants. nuclear power plants, and food processing facilities. But, the zone affected by heat in the range of 400 to $800^{\circ}C$ during welding loses corrosion resistance and tensile strength since Cr-carbide precipitation like $Cr_{23}C_6$ forms at the grain boundary and thereby takes place the intergranular corrosion. In this study, AISI 304 stainless steel with the added Nb of 0.3 to 0.7 wt% was solutionized at $1050^{\circ}C$ and sensitized at $650^{\circ}C$. Specimen was welded by MIG. The phase and the microstructure of the specimens were examined by an optical microscope, a scanning electron microscope, and a x-ray diffractometer. The corrosion characteristics of specimens were tested by electrolytic etching and by double loop electrochemical potentiokinetic reactivation method(EPR) in the mixed solution of 0.5M $H_2SO_4$ + 0.01M KSCN. The melting zone had dendritic structure constituted of austenitic phase and $\delta$-ferrite phase. Cr carbide at the matrix did not appear, as Nb content increased. At the grain boundaries of the heat affected zone, the precipitates decreased and the twins appeared. The hardness increased, as Nb content increased. The hardness was highest in the order of the heat affected zone>melted zone>matrix. According to EPR curve, as the Nb content decreased, the reactivation current density(Ir) and the activation current density(la) were highest in the order of the melted zone

전기화학적 방법에 의한 내열강의 열화도측정 제2보 : 열화도측정치에 미치는 측정조건들의 영향과 기계적성질 변화에 대해서 (Degradation Degree Evaluation of Heat Resisting Steel by Electrochemical Technique Part 2 : Effect of Testing Conditions on Evaluation Value of Degradation Degree and Changes of Mechaical Properties)

  • 정희돈;권영각;장래웅
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.300-312
    • /
    • 1993
  • The material deterioration of service-exposed boiler tube steels in fossil power plant was evaluated by using the electrochemical technique namely, modified electrochemical potentiokinetic reactivation(EPR). It was focused that the passivation of Mo$_{6}$C carbide which governs the mechanical properties of Mo alloyed steels did not occur even in the passivity region of steel in sodium molybdate solution and the reactivation peak current (Ip) observed as the result of non-passivation indicating the precipitation of Mo$_{6}$C carbides. To obtain the optimal test conditions for the field test by using the specially designed electrochemical cell, the effects of scan rate, the surface roughness and the pH of electrolyte on Ip value were also investigated. Furthermore, the change of mechanical properties occurred during the long time exposure at high temperature was evlauated quantitatively by small punch(SP) tests and micro hardness test taking account of the metallurgical changes. It is known that reactivation peak current (Ip) has a good relationship with Larson-Miller Parameter(LMP) which represents the information about material deterioration occurred at high temperature environment. In addition it was possible to estimate the ductile-brittle transition temperature (DBTT) by means of the SP test. The Sp test could be, therefore, suggested as a reliable test method for evaluating the material degradation of boiler tube steels. From the good correaltion between the SP DBTT and Ip values shown in this study, it was knows that the change of mechanical properties could be evaluated non-destructively by measurring only Ip values.ues.

전기화학적 방법에 의한 주조 스테인리스강 CF8M $\sigma$상 열화평가 (Evaluation of the $\sigma$-Phase Degradation for Cast Stainless Steel CF8M by the Electrochemical Method)

  • 권재도;김중형;박중철;변장환;이우호
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.2014-2021
    • /
    • 1999
  • The present investigation is concerned with the degradation characteristics of cast stainless steel(CF8M), exposed to the $\sigma$-phase degradation at $700^{\circ}C$. In the present paper, the degradation of CF8 M at $700^{\circ}C$ is evaluated by a non-destructive test, DL-EPR(double loop electrochemical potentiokinetic reactivation). The surface of specimens is observed by using scanning electron microscopy after DL-EPR test. Also. chromium contents of matrix, grain boundary and ferrite phase are analyzed by electron probe X-ray micro analyzer. Through the experiments, the following results are obtained 1) The degree of sensitization(DOS) of CF8M aged up to 15hr at $700^{\circ}C$ is increased with acing time while that is decreased with aging time from 15hr to 150hr. 2) The impact energy decreases with increase of $\sigma$-phase while DOS increases with $\sigma$-phase until aging time reaches to 15hr. After the aging time. 15hr, the $\sigma$-phase and the rate of impact energy with respect to aging time decreases. Therefore the degradation behavior of the CF8M can be evaluated by comparing SEM micrographs and the value of DOS.

電氣化學的 方法에 의한 耐熱鋼의 劣化度 測定 제1보 (Degradation Degree Evaluation of Heat Resisting Steel by Electrochemical Technique (Part I : Mechanism and Its Possibility of Field Application))

  • 정희돈;권녕각
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.598-607
    • /
    • 1992
  • 본 연구에서는 고온중 장시간 사용중에 일어나는 야금학적 성질의 변화의 추 원인인 특정 탄화물을 비파괴적으로 검출하기 위해, 최근에 연구 되고 있는 전기화학 적 방법을 응용하기 위한 기초연구이다. 한편으로는 비파괴적 방법의 실험실적 연구 를 현장에 응용시키기 위한 시도를 행하고, 본 연구 결과를 이용한 향후 설비 진단 시 스템의 개요를 고찰해 보인다.

공정 디자인에 따른 클래드강 맞대기 용접부의 기계적 특성에 관한 연구 (A Study on the Mechanical Properties of Butt Welding Zone of Clad Steel According to the Process Design)

  • 이정현;박재원
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.532-540
    • /
    • 2012
  • In this study, some considerations have been suggested in developing on-site techniques to evaluate the sensitization of stainless steels. Electrochemical potentiokinetic reactivation (EPR) technique is known to be a candidate tool for field applications since it enables quantitative assessment in reasonable test time, compared to oxalic etching (ditch) technique. The on-site application of the test method imposes additional restrictions on the selection of the test method (for example, minimum surface preparation requirement, insensitivity to testing temperature, etc.). The EPR and etching techniques have been compared in order to sensitization of stainless steel structures. It has been widely reported that the maximum sensitivity in the welded structure of stainless steel is shown at heat-affected zone (HAZ) than weldments with cast structure. In this work, sectioned weldments and external surfaces were investigated to reveal the degree of sensitization by the etching and the results were compared with those of EPR test. The EPR test showed little sensitivity to surface roughness and test temperature.

Evaluation of 475 ℃ embrittlement in UNS S32750 super duplex stainless steel using four-point electric conductivity measurements

  • Gutierrez-Vargas, Gildardo;Ruiz, Alberto;Lopez-Morelos, Victor H.;Kim, Jin-Yeon;Gonzalez-Sanchez, Jorge;Medina-Flores, Ariosto
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2982-2989
    • /
    • 2021
  • One of the consequences of the 475 ℃ embrittlement of duplex stainless steels is the reduction of the resistance to localized corrosion. Therefore, the detection of this type of embrittlement before the material exhibits significant loss in toughness, and corrosion resistance is important to ensure the structural integrity of critical components under corrosion threats. In this research, conductivity measurements are performed using the alternating current potential drop (ACPD) technique with using a portable four-point probe as a nondestructive evaluation (NDE) method for detecting the embrittlement in a 2507 (UNS S32750) super duplex stainless steel (SDSS) aged at 475 ℃ from as-received condition to 300 h. The electric conductivity results were compared against two electrochemical tests namely double loop electrochemical potentiokinetic reactivation (DL-EPR) and critical pitting temperature (CPT). Mechanical tests and the microstructure characterized using scanning electron microscopy (SEM) imaging are conducted to track the progress of embrittlement. It is shown that the electric conductivity correlates with the changes in impact energy, microhardness, and CPT corrosion tests result demonstrating the feasibility of the four-point probe as a possible field-deployable method for evaluating the 475 ℃ embrittlement of 2507 SDSS.