• Title/Summary/Keyword: electrocardiography (ECG)

Search Result 78, Processing Time 0.024 seconds

Development of Time Varying Kalman Smoother for Extracting Fetal ECG using Independent Component Analysis : Preliminary Study (독립요소분석을 이용한 태아심전도 추출을 위한 시변 칼만 평활기의 개발 : 예비연구)

  • Lee, Chung Keun;Kim, Bong Soo;Kwon, Ja Young;Choi, Young Deuk;Song, Kwang Soup;Nam, Ki Chang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.202-208
    • /
    • 2012
  • Fetal heart rate monitoring is important information to assess fetal well-being. Non-invasive fetal ECG (electrocardiography) can be derived from maternal abdominal signal. And various promising signal processing methods have been introduced to extract fetal ECG from mother's composite abdominal signal. However, non-invasive fetal ECG monitoring still has not been widely used in clinical practice due to insufficient reliable measurement and difficulty of signal processing. In application of signal processing method to extract fetal ECG, it might be lower signal to noise ratio due to time varying white Gaussian noise. In this paper, time varying Kalman smoother is proposed to remove white noise in fetal ECG and its feasibility is confirmed. Wiener process was set as Kalman system model and covariance matrix was modified according to white Gaussian noise level. Modified error covariance matrix changed Kalman gain and degree of smoothness. Optimal covariance matrix according to various amplitude in Gaussian white noise was extracted by 5 channel fetal ECG model, and feasibility of proposed method could be confirmed.

Nonlinear analysis of cardiotonic effect of acupuncture treatment on heart rate variability assessed by 24-hour Holter monitoring (침처치의 24시간 심박변이도 영향에 대한 비선형 분석)

  • Oh, Dal-Seok;Lee, Jeon;Kim, Jong-Yeol;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • This study is to investigate cardiotonic effect of acupuncture on heart rate variability(HRV) analyzed by a nonlinear way(DFA, Detrended Fluctuation Analysis). It was designed as a randomized, single-blind, waiting list-controlled, cross-over study. We assessed heart rate and R-R intervals in Circadian electrocardiography with a Holter monitoring device for twelve hospitalized participants. The compatible analytical program, Zymed, was used for generating the signals of R-R intervals from 24 hour-ECG. In DFA analysis, we produced DFA alpha 1, alpha 2 parameters according to the process of Cygwin module of Linux server. We tested if there was any difference between HRV parameters using SPSS, a statistical package. There was no difference between acupuncture and no treatment group in DFA alpha 2 parameter {95% Confidence Interval (-)0.058 - 0.037, P = .565}. Two group all showed large intra-individual variations. Consequently, acupuncture treatment did not modulate the complexity of HRV in a DFA analysis. This study can be a rationale for acupuncture's properties on cardiovascular and autonomic systems.

  • PDF

Severe hypermagnesemia presenting with abnormal electrocardiographic findings similar to those of hyperkalemia in a child undergoing peritoneal dialysis

  • Jhang, Won Kyoung;Lee, Yoon Jung;Kim, Young A;Park, Seong Jong;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.7
    • /
    • pp.308-311
    • /
    • 2013
  • In this report, we present a pediatric case of severe symptomatic hypermagnesemia resulting from the use of magnesium oxide as a laxative in a child undergoing continuous cyclic peritoneal dialysis for end-stage renal disease. The patient showed abnormal electrocardiography (ECG) findings, such as tall T waves, a widened QRS complex, and irregular conduction, which were initially misdiagnosed as hyperkalemia; later, the correct diagnosis of hypermagnesemia was obtained. Emergent hemodialysis successfully returned the serum magnesium concentration to normal without complications. When abnormal ECG changes are detected in patients with renal failure, hypermagnesemia should be considered.

Multifocal Atrial Tachycardia in a Newborn (신생아에서 발생한 다소성심방빈맥)

  • Cho, Hye-Jung;Son, Dong-Woo;Shim, So-Yeon;Choi, Deok-Young;Lee, Ji-Sung;Bae, Eun-Jung
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.239-243
    • /
    • 2009
  • Multifocal atrial tachycardia (MAT) is a rare arrhythmia in the newborn. MAT can be difficult to diagnose; it is frequently confused with atrial fibrillation. MAT is difficult to treat but often resolves spontaneously within the first year of life. A newborn with a rapid and irregular pulse rate was diagnosed with multifocal atrial tachycardia by eletrocardiography (ECG) using a hand-made transesophageal electrode. Treatment with propranolol was attempted but ineffective. Treatment with digoxin and sotalol was attempted. The heart rhythm gradually reverted to a sinus rhythm with this treatment. We report our experience managing a neonate with MAT diagnosed by ECG using a hand-made transesophageal electrode.

A Study on MCG Imaging (MCG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

2018 심방세동 카테터 절제술 대한민국 진료지침: PART III

  • Lee, Jeong-Myeong;Jeong, Dong-Seop;Yu, Hui-Tae;Park, Hyeong-Seop;Sim, Jae-Min;Kim, Ju-Yeon;Kim, Jun;Yun, Nam-Sik;O, Se-Il;No, Seung-Yeong;Jo, Yeong-Jin;Kim, Ki-Hun
    • International Journal of Arrhythmia
    • /
    • v.19 no.3
    • /
    • pp.285-339
    • /
    • 2018
  • Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional electrophysiological procedures. The success of AF ablation is based in large part on freedom from AF recurrence based on electrocardiography (ECG) monitoring. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. This section reviews the complications associated with catheter ablation procedures performed to treat AF. The types and incidence of complications are presented, their mechanisms are explored, and the optimal approach to prevention and treatment is discussed. Finally, surgical and hybrid AF ablation technology and the indications for concomitant open or closed surgical ablation of AF, stand-alone and hybrid surgical ablation of AF are covered in this section.

QT dispersion in children with Kawasaki disease

  • Song, Bo-Kyung;Sung, Kyoung;Cho, Min-Jung;Lee, Hyoung-Doo
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.94-98
    • /
    • 2014
  • Background: We analyzed the changes in QT dispersion (QTd) in children with Kawasaki disease (KD), and determined the presence of repolarization abnormality in these children even in the absence of coronary artery abnormalities. Methods: Ninety-one children with KD and 20 healthy controls were enrolled in this retrospective study. Serial echocardiographic and electrocardiographic (ECG) measurements in the beginning of treatment, 2nd month and 6th month after the diagnosis were compared. Fifty-one of 91 children had at least 2 serial ECG data. The number of patients who had 3 consecutive ECG data was 23. Results: Among the 67 KD patients with no coronary artery changes, the consecutive mean QTd values were 41.86 ms, 37.84 ms, and 25.47 ms, respectively (26 ms for controls). In the analysis of changes among KD patients without coronary artery abnormalities, QTd showed a significant decrease with time (p=0.01). Especially, the 1st month and the 6th month QTd values were significantly different (p=0.028). The mean QTd values in KD patients with coronary artery changes were significantly higher than those in KD patients with no coronary artery changes at each time (1st, 2nd, and 6th month exam). Conclusion: QTd is significantly increased in children during the early stage of KD. Repolarization abnormality may exist during the acute stage of KD, regardless of the echocardiographic changes.

Effect of emergency bell on door to ECG time in walk-in patients presented to emergency department with chest pain (흉통을 주소로 응급실에 내원한 환자에서 심전도 촬영 소요 시간에 대한 응급벨 제도의 효과)

  • Kim, Min-Woo;Oh, Sang-Hoon;Park, Kyu-Nam;Lee, Jung-Min;Lee, Young-Mee;Kim, Han-Joon;Kim, Soo-Hyun;Kang, Dong-Jae
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.12-24
    • /
    • 2014
  • Objectives: The aim of this study was to explore whether emergency bell could shorten door to electrocardiograms (ECG) time in chest pain patients presenting to emergency department (ED) by self-transport. Methods: This was a planned 6-month before-and-after interventional study design. We set up the emergency bell in walk-in patients' waiting room. Prior to the change, patients were triaged before an ECG was obtained. In new process, as soon as patient with chest pain push the emergency bell, emergency physicians examined patient and prioritized performing ECG. We analyzed door to electrocardiograms (DTE) times for patients with chest pain and ST segment elevation myocardial infarction (STEMI) patients between two periods. Results: During the enrollment period, a total of 63 patients called emergency bell. The median DTE time was 6 min (interquartile range: 3.0 - 9.0) and 82.5% received an ECG within 10 minutes, and only three patients were STEMI. DTE time in patient with chest pain was not different between two periods (p=0.980). Before intervention period, 15 walk-in patients admitted in ED for STEMI and 53.8% of STEMI patients received an ECG within 10 minutes. After intervention period, total 19 walk-in patients admitted in ED for STEMI. Of these, 89.5% met the time requirement. Conclusion: Because a small portion of patients with chest pain activated the emergency bell, new strategy for promotion of emergency bell must be needed.

Design of Hybrid Unsupervised-Supervised Classifier for Automatic Emotion Recognition (자동 감성 인식을 위한 비교사-교사 분류기의 복합 설계)

  • Lee, JeeEun;Yoo, Sun K.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1294-1299
    • /
    • 2014
  • The emotion is deeply affected by human behavior and cognitive process, so it is important to do research about the emotion. However, the emotion is ambiguous to clarify because of different ways of life pattern depending on each individual characteristics. To solve this problem, we use not only physiological signal for objective analysis but also hybrid unsupervised-supervised learning classifier for automatic emotion detection. The hybrid emotion classifier is composed of K-means, genetic algorithm and support vector machine. We acquire four different kinds of physiological signal including electroencephalography(EEG), electrocardiography(ECG), galvanic skin response(GSR) and skin temperature(SKT) as well as we use 15 features extracted to be used for hybrid emotion classifier. As a result, hybrid emotion classifier(80.6%) shows better performance than SVM(31.3%).

Ubiquitous wireless Electrocardiography System (유비쿼터스 무선 심전도기)

  • Kim, P.K.;Cho, S.H.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2151-2152
    • /
    • 2006
  • 초고속 인터넷과 무선 전송 등 통신기술이 급속히 발전되면서 보다 간편하게 건강 상태를 검진할 수 있는 방법에 대한 연구가 많이 진행되고 있다. 건강상태를 지속적으로 확인하기 위해서는 생체 신호 측정 장비의 높은 휴대성과 편리성, 정확한 측정이 가능해야 한다. 본 연구에서는 정확한 측정과 높은 휴대성을 위하여, 생체 신호 측정 장비를 소형화 및 저전력화를 실현하였고, 활동성을 위해 근거리 무선 통신 방식인 Bluetooth를 사용하였다. 개발된 유비쿼터스 무선 ECG 시스템은 일상적인 심전도 측정이 가능하여 협심증, 심근경색, 부정맥 등 심장질환의 조기 진단에 유용하게 사용 될 것이 기대된다.

  • PDF