• 제목/요약/키워드: electrocardiography

검색결과 184건 처리시간 0.021초

The evolution of electrocardiographic changes in patients with Duchenne muscular dystrophies

  • Yoo, Woo Hyun;Cho, Min-Jung;Chun, Peter;Kim, Kwang Hun;Lee, Je Sang;Shin, Yong Beom
    • Clinical and Experimental Pediatrics
    • /
    • 제60권6호
    • /
    • pp.196-201
    • /
    • 2017
  • Purpose: Myocardial dysfunction and dysrhythmias are inevitable consequences of Duchenne muscular dystrophy. We aimed to evaluate specific trends of electrocardiographic changes that reflect the progress of cardiomyopathy in patients with Duchenne muscular dystrophy. Methods: Fifty electrocardiograms (ECGs) of 30 patients (ages 1 to 27 years) who had not been prescribed medications for heart failure treatment at the time of examination were retrospectively analyzed and compared with 116 ECGs of age-matched healthy 116 controls. Heart rate, leads with fragmented QRS (fQRS), corrected QT, Tpeak-to-Tend, and Tpeak-to-Tend/QT were analyzed. Results: The patients with Duchenne muscular dystrophy failed to show a normal age-related decline in heart rate but showed an increasing trend in the prevalence of fQRS, corrected QT, corrected Tpeakto-Tend, and Tpeak-to-Tend/QT over time. In the ${\leq}10-year-old$ patient group, a significant difference was found only in the prevalence of fQRS between the patients and the controls. The prevalence of fQRS, heart rate, Tpeak-to-Tend/QT, and corrected Tpeak-to-Tend demonstrated significant differences between the patients and the controls in the middle age group (11 to 15 years old). All the indexes were statistically significantly different in the ${\geq}16-year-old$ patient group. Conclusion: The prevalence of lead with fQRS representing regional wall motion abnormalities was higher in the young patients than in the young healthy controls, and this might be one of the first signs of myocardial change in the patients. Markers of depolarization and repolarization abnormalities were gradually prominent in the patients aged >10 years. Further studies are needed to confirm these findings.

발작성 심방세동 환자의 P파 간격 측정 방법에 관한 연구 (A Study for measurement method of P-wave duration in Paroxysmal Atrial Fibrillation(PAF) subjects)

  • 이종연;여형석;한완택;김인영;이병채;김준수;민정선;서정돈;이원로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.181-182
    • /
    • 1998
  • In previous study for correlation between P-wave Signal Averaged Electrocardiography (SAECG) and Paroxysmal Atrial Fibrillation (PAF) subjects, we showed that the duration of P-wave in subjects is longer than in controls. In this respect, the P-wave SAECG is a new method proving to be an accurate and independent noninvasive marker for the risk of PAF. To prove this suggestion, accurate detection and alignment of P-wave are indispensible. In previous study, we measured P-wave duration by manual. So it was not accurate and consistent. To measure the P-wave duration accurately and automatically, we have developed an automatic algorithm for P-wave duration measurement. We showed that the duration of P- wave in the subjects is longer than in controls with this algorithm.

  • PDF

응급실에서 심자도의 역할 (Role of Magnetocardiography in Emergency Room)

  • 권혁찬;김기웅;김진목;이용호;김태은;임현균;박용기;고영국;정남식
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.40-45
    • /
    • 2006
  • In emergency rooms, patients with acute chest pain should be diagnosed as quickly as possible with higher diagnostic accuracy for an appropriate therapy to the patients with acute coronary syndrome or for avoiding unnecessary hospital admissions. At present, electrocardiography(ECG) and biochemical markers are generally used to detect myocardial infarction and coronary angiography is used as a gold standard to reveal the degree of narrowing of coronary artery. Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool fur the detection of cardiac electrical abnormality associated with myocardial ischemia. In this study, we examined whether the MCG can be used fur the detection of coronary artery disease(CAD) in patients, who were admitted to the emergency room with acute chest pain. MCG was recorded from 36 patients admitted to the emergency room with suspected acute coronary syndrome. The MCG recordings were obtained using a 64-channel SQUID MCG system in a magnetically shielded room. In result, presence of CAD could be found with a sensitivity of 88.2 % in patients with acute chest pain without 57 elevation in ECG, demonstrating a possible use in the emergency room to screen CAD patients.

  • PDF

The Importance of Esophageal and Gastric Diseases as Causes of Chest Pain

  • Kim, Yong Joo;Shin, Eun Jung;Kim, Nam Su;Lee, Young Ho;Nam, Eun Woo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권4호
    • /
    • pp.261-267
    • /
    • 2015
  • Purpose: Pediatric chest pain is considered to be idiopathic or caused by benign diseases. This study was to find out how much upper gastrointestinal (UGI) diseases are major causes of chest pain in pediatric patients. Methods: The records of 75 children (42 boys and 33 girls, aged 3-17 years old) who have presented with mainly chest pain from January 1995 to March 2015 were retrospectively reviewed. Chest X-ray and electrocardiography (ECG) were performed in all aptients. Further cardiologic and gastrointestinal (GI) evaluations were performed in indicated patients. Results: Chest pain was most common in the children of 6 and 9 to 14 years old. Esopha-gogastric diseases were unexpectedly the most common direct causes of the chest pain, the next are idiopathic, cardiac diseases, chest trauma, respiratory disease, and psychosomatic disease. Even though 21 showed abnormal ECG findings and 7 showed abnormalities on echocardiography, cardiac diseases were determined to be the direct causes only in 9. UGI endoscopy was performed in 57 cases, and esophago-gastric diseases which thereafter were thought to be causative diseases were 48 cases. The mean age of the children with esophago-gastric diseases were different with marginal significance from that of the other children with chest pain not related with esophago-gastric diseases. All the 48 children diagnosed with treated with GI medicines based on the diagnosis, and 37 cases (77.1%) subsequently showed clinical improvement. Conclusion: Diagnostic approaches to find out esophageal and gastric diseases in children with chest pain are important as well as cardiac and respiratory investigations.

관상동맥질환에 있어서 관상동맥우회술과 내막제거술의 효과 (Coronary Artery Bypass Graft with Coronary Thromboendarterectomy in Coronary Artery Disease)

  • 정종수;지행옥
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.1092-1100
    • /
    • 1989
  • Since May 1987 to April 1989, fifteen patients have been subjected to coronary artery bypass graft [CABG] including coronary thromboendarterectomy in 3 patients at Hanyang University Hospital. The correlation between the preoperative coronary angiography, electrocardiography, clinical status, operative finding and postoperative blood flow, complication and degree of clinical improvement were evaluated. 1. Ten patients [67 %] were male and five patients [33 %] were female, Ages ranged from 30 to 68 years. [average 52.2 years] 2. The angina by types of presentation was stable in 3 patients, unstable in 12 patients with resting, postinfarction and progressive angina as the criteria of unstability. 3. The number of involved vessels were single in 6 cases, double in 4 cases, triple in 5 cases including 1 case of left main coronary arterial disease. 4. The distribution of sites of distal anastomosis revealed predilection to left coronary arterial system [83 %], especially left anterior descending arterial system. 5. The author performed 4 cases of single bypass, 4 cases of double bypass, 5 cases of triple bypass and 2 cases of quadruple bypass. Of these 15 patients, 3 patients received coronary thromboendarterectomy, LAD in 2 patients and right coronary artery [RCA] in 1 patient. 6. The distal anastomosis were performed first with using saphenous vein grafts as conduits in all cases except 1 case using Gore-Tex conduit because of deficient in length and narrowed internal mammary artery and sequential bypass methods were employed in last 6 cases. 7. One operative death occurred and therefore, mortality rate was 6.7%. The perioperative myocardial infarction were occurred in 3 cases [20%] and its cause was supposed that they were triple vessel disease and therefore, aortic cross clamping times were relatively long. 8. All survivors were followed for 17.7 months on an average [range 5-28 months] and they have had symptomatic improvement except 1 case having mild degree of angina at 1.5 months after operation.

  • PDF

조기심실수축(PVC) 분류를 위한 환자 적응형 패턴 매칭 기법 (Patient Adaptive Pattern Matching Method for Premature Ventricular Contraction(PVC) Classification)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제16권9호
    • /
    • pp.2021-2030
    • /
    • 2012
  • 조기심실수축(PVC)은 가장 보편적인 부정맥으로 심실세동, 심실빈맥 등과 같은 위험한 상황을 유발할 수 있는 가능성을 가지고 있기 때문에 이의 조기 검출은 매우 중요하다. 특히 일반인들의 건강상태를 지속적으로 모니터링 해야 하는 헬스케어 시스템에서는 이를 위한 심전도 신호의 실시간 처리가 필요하다. 즉, 최소한의 연산량으로 정확한 R파를 검출하고, 대상 환자의 특징을 파악하여 PVC를 분류할 수 있는 적합한 알고리즘의 설계가 필요하다. 따라서 본 연구에서는 PVC 실시간 분류를 위한 환자 적응형 패턴 매칭 기법을 제안한다. 이를 위해 전 처리 과정과 적응 가변형 문턱 값과 윈도우를 통해 R파를 검출하였으며, 검출 대상에 따른 정상신호 군을 선별하고 이를 벗어나는 신호를 이상신호로 분류하기 위해 해쉬 함수를 통한 패턴 매칭 기법을 적용하였다. 제안한 알고리즘의 R파 검출 및 정상신호 분류 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, R파는 평균 99.33%, 이상신호 분류에 대한 에러율은 0.32%로 나타났다.

운전자의 심리·생리 반응을 고려한 승용차 쾌적 난방 모드에 관한 연구 (Research on the Thermal Comfort Heating Mode Considering Psychological and Physiological Response of Automobile Drivers)

  • 김민수;금종수;박종일;김동규
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.149-157
    • /
    • 2018
  • In this research, the psychological and physiological reactions of the driver were measured during winter to evaluate thermal comfort. The experiment was conducted using 3 different cases which are hot air heating, warm-wire seat heating and hot air & warm-wire seat heater operating simultaneously. With regard to psychological reaction, the warm-wire heating mode was the most preferred. The reason is that it is dry in other cases. With regard to EEG response, thermal comfort increased by 37% in warm air mode heating. In addition, when the warm-wire heating mode and the hot air & warm-wire heating mode were simultaneously operated, the thermal comfort continuously increased by between 17% and 20% for 20 minutes after boarding. Under the change of the autonomic nervous system, the thermal stress level increased by 23% after 15 minutes on board in the hot air heating mode and decreased continuously by 13% during the warm-wire seat heating mode. We recommended the hot air heating mode is only used for a short time to raise the inside temperature during the early boarding period and that warm-wire seat heating mode be actively utilized.

ECG 패턴 분석과 템플릿 문턱값을 통한 조기수축 부정맥분류 (Premature Contraction Arrhythmia Classification through ECG Pattern Analysis and Template Threshold)

  • 조익성;조영창;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.437-444
    • /
    • 2016
  • 일반적인 부정맥 분류 방법의 경우 심방 박동 수와 관련한 PP간격, P모양의 다양성과 같은 조건을 이용하는데, 잡음으로 인해 정확한 P파의 검출이 어렵기 때문에 잡음의 영향을 비교적 적게 받는 R파를 이용하는 것이 유리하다. 따라서 본 연구에서는 R파 중심의 ECG(electrocardiography) 패턴 분석과 템플릿 문턱치를 도입하여 조기수축 부정맥 분류 방법을 제안한다. 이를 위해 형태 연산을 통한 전 처리 과정과 차감 동작 기법을 통해 R파를 검출하였다. 이후 RR 간격의 평균 가중치와 변화율을 이용하여 먼저 조기수축 파형의 패턴을 분류하고, R파의 진폭에 대한 템플릿 문턱값을 통해 조기심실수축과 조기심방수축을 분류하는 알고리즘을 개발하였다. 제안한 방법의 우수성을 입증하기 위해 조기 심방과 심실수축이 30개 이상 포함된 MIT-BIH 6개의 레코드를 대상으로 한 R파의 평균 검출율은 99.77%의 성능을 나타내었고, 조기심실수축과 심방수축 부정맥은 각각 94.91%와 95.76%의 평균 분류율을 나타내었다.

Anti-ischemic Effects of Nimesulide, a Cyclooxygenase-2 Inhibitor on the Ischemic Model of Rabbit Induced by Isoproterenol

  • Saeed, Sheikh Arshad;Ahmed, Sagheer
    • Archives of Pharmacal Research
    • /
    • 제29권11호
    • /
    • pp.977-983
    • /
    • 2006
  • The objective was to devise an animal model of myocardial infarction (MI) against which cardioprotective drugs might be tested. We describe the effects of nimesulide, a COX experience with development and validation of such a model. The rabbit was chosen in preference to rodents because its heart and cardiac circulation more closely resemble those of human. Thus, the cardiovascular system of anaesthetized male rabbits, 1 to 1.5 kg (n=11), was stressed by a single bolus intravenous injection of isoprenaline (ISP), 65 mg/kg. The effects of the injection were followed for sixteen days and were evaluated in four ways: 1) measurements of creatinine kinase isozyme and troponin-I (TPI) in serum 2) Electrocardiographic (ECG) changes (ST elevation and Q wave development) 3) Cardiac histopathology observed in tissue sections of the isolated of the heart. The histopathological analysis showed that rabbit heart on 2nd day after ISP injection showed changes of coagulation necrosis. Day 4 total coagulation with the loss of nuclear and striation associated with heavy interstitial infiltrate of neutrophils was found. Day 8 after infarction showed collagen deposition with capillary channels in between the remaining islands of myocytes in the infarcted area. On the 16th day scarring was complete. Coronary perfusion rates (CPR) and heart rate (HR) of the infarcted and nimesulide (a COX-2 inhibitor) treated rabbits displayed significant improvement (n=11) on each corresponding day after infarction as compared to the infarcted and saline treated rabbits (P<0.05). All four indices revealed similarities with effects commonly associated with MI in humans.

심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로- (Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment-)

  • 정연희;양영모
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.