• Title/Summary/Keyword: electro-optic

Search Result 414, Processing Time 0.031 seconds

Buckling treatment of piezoelectric functionally graded graphene platelets micro plates

  • Abbaspour, Fatemeh;Arvin, Hadi
    • Steel and Composite Structures
    • /
    • v.38 no.3
    • /
    • pp.337-353
    • /
    • 2021
  • Micro-electro-mechanical systems (MEMS) are widely employed in sensors, biomedical devices, optic sectors, and micro-accelerometers. New reinforcement materials such as carbon nanotubes as well as graphene platelets provide stiffer structures with controllable mechanical specifications by changing the graphene platelet features. This paper deals with buckling analyses of functionally graded graphene platelets micro plates with two piezoelectric layers subjected to external applied voltage. Governing equations are based on Kirchhoff plate theory assumptions beside the modified couple stress theory to incorporate the micro scale influences. A uniform temperature change and external electric field are regarded along the micro plate thickness. Moreover, an external in-plane mechanical load is uniformly distributed along the micro plate edges. The Hamilton's principle is employed to extract the governing equations. The material properties of each composite layer reinforced with graphene platelets of the considered micro plate are evaluated by the Halpin-Tsai micromechanical model. The governing equations are solved by the Navier's approach for the case of simply-supported boundary condition. The effects of the external applied voltage, the material length scale parameter, the thickness of the piezoelectric layers, the side, the length and the weight fraction of the graphene platelets as well as the graphene platelets distribution pattern on the critical buckling temperature change and on the critical buckling in-plane load are investigated. The outcomes illustrate the reduction of the thermal buckling strength independent of the graphene platelets distribution pattern while meanwhile the mechanical buckling strength is promoted. Furthermore, a negative voltage, -50 Volt, strengthens the micro plate stability against the thermal buckling occurrence about 9% while a positive voltage, 50 Volt, decreases the critical buckling load about 9% independent of the graphene platelet distribution pattern.

Fixed and Moving Automatic FOD Detection Test using Radar and EO Camera (소형 Radar와 EO 카메라를 이용한 고정형 및 이동형 FOD 자동탐지 시험)

  • Kim, Young-Bin;Kim, Sung-Hee;Park, Myung-Kyu;Park, Kwang-Gun;Kim, Min-su;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.479-484
    • /
    • 2020
  • Foreign object debris (FOD) is a generic term for all substances that may pose a threat to aircraft operations on a runway. In the past, FOD detection and collection methods using human resources were very inefficient in terms of efficiency and economics, so it is essential to develop an unmanned FOD detection system suitable for domestic use. In this paper, the fixed FOD automatic detection system and mobile FOD automatic detection system using EO camera and radar were studied and developed at the Taean airfield of Hanseo University, and fixed and mobile method were operated to confirm that automatic FOD detection in the runway of the airfield is possible regardless of illumination and weather conditions.

Growth of $LiTaO_3$ and Fe doped-LiTaO3 single crystal as holographic storage material (홀로그래피 소자재료 $LiTaO_3$단결정 성장)

  • 김병국;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.193-204
    • /
    • 1998
  • The single crystal of the $LiTaO_3$has large electro-optic effects, so it is applied to optical switch, acousto-optic deflector, and optical memory device as hologram using photorefractive effect. In this study, optic-grade undoped $LiTaO_3$and Fe:LiTaO$LiTaO_3$single crystals were grown by the Czochralski method and optical transmission and absorption spectrums were measured in the wavelength of UV-VIS range. The curie temperature was determined with DSC and by measuring capacitance for the grown undoped crystal and ceramic powder samples of various Li/Ta ratio. In case of having a 48.6 mol% $Li_2O$ as a starting Li/Ta ratio, the results of concentration variations were below 0.01 mol% $Li_2O$ all over the crystal, so it was confirmed that $LiTaO_3$single crystals were grown under congruent melting composition having optical homogeneity. The curie temperature of the Fe:$LiTaO_3$crystal was increased with increased with increased doped Fe concentrations;by the ratio of $7.5^{\circ}C$ increase per Fe 0.1 wt%. Also, the optical transmittance was about 78 %, which was sufficient for optical device.

  • PDF

Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment (세포 실험용 다중 주파수 동시 노출 장치 제작)

  • Kim, Tae-Hong;Seo, Min-Gyeong;Mun, Ji-Yeon;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.213-219
    • /
    • 2012
  • Recently, we are simultaneously exposed by various electromagnetic sources due to an increase of mobile communication services. However, EMF(Electric, Magnetic and Electromagnetic Field) study has been performed mainly about only single frequency. The objective of this paper is to develop an multiple-frequency exposure system for in vitro experiment. The exposure unit for in vitro experiments was designed by radial transmission line type to get broadband characteristics to generate signals of CDMA at 836.5 MHz and WCDMA at 1950 MHz frequency simultaneously. The modulated signals were delivered to the conical antenna through amplifier, digital attenuator and RF combiner. SAR values were obtained by the averaged values of 3 measured values at 9 points in petri dish using the fiber optic temperature probe. The measured return loss was under -15 dB. For 1 W input power, the mean value and standard deviation of SAR were $0.105{\pm}0.019$ for the CDMA frequency and $0.262{\pm}0.055$ for the WCDMA frequency.

Node Architecture and Cell Routing Strategies for ATM Applications in WDM Multihop Networks (WDM 다중홉 망에서 ATM 응용을 위한 노드 구조 및 셀 라우팅 기법)

  • Lee, Ho-Suk;Lee, Cheong-Hun;So, Won-Ho;Kwon Hyeok-Jung;Kim, Yeong-Cheon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.44-52
    • /
    • 1998
  • In this paper, we proposed a node architecture and cell routing strategies for ATM applications in WDM multihop networks. The proposed node architecture employs the optical delay loop for storing the cell which is failed in out-link contention. This optical delay loop allows the delay of one cell without the electro-optic conversion. Therefore, we can get the advantages of S&F(Store-and-Forward) routing in Deflection-based all-optical networks. To support the ATM applications efficiently. we considered the transmission priority of ATM cell so that high priority cell can be transmitted with lower loss and shorter delay than low priority one. Two kinds of routing strategies are designed for this architecture: Scheme-Ⅰand Scheme-Ⅱ. Scheme-Ⅰapplies S&F routing to high cell and Deflection routing to low cell, i.e., high cells are routed along the shortest path based on S&F routing, but low cells are deflected or lost. Schem-Ⅱ is similar to Scheme-Ⅰexcept that low cells can occupy the optical loop if it is available. This Scheme-Ⅱ increases the utilization of network resources without decreasing the throughput of high cell by reducing the low cell loss rate when traffic load is low. Simulation results show that our routing strategies have better performance than conventional ones under non-uniform traffic as well as uniform traffic.

  • PDF

Electro-optic characteristics of novel biased vertical alignment device using the polymerized reactive mesogen (광경화성 단분자를 이용한 새로운 수직배향 액정 디바이스의 전기 광학적 특성연구)

  • Kim, Dae-Hyun;Kim, Sung-Min;Cho, In-Young;Kim, Woo-Il;Kwon, Dong-Won;Son, Jong-Ho;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.269-270
    • /
    • 2009
  • The biased vertical alignment (BVA) liquid crystal (LC) mode shows a has a distinct advantage of lower manufacture cost due to the elimination of a lithographic process step to form either ITO-patterning or protrusions on the color-filter substrates. However, those devices have complex voltage conditions which is the respective induce voltage on common electrode, pixel electrode and bias electrode when positive and negative frame. In order to overcome the complex voltage condition, the pretilt angles is controlled by photo polymerization of the UV-curable reactive mesogen (RM). According to our studies, voltages to the cell are critical to achieve an optimized surface-modified quality BVA (Q-BVA) mode which provides the well defined reorientation of the LCs with respect to an electric field.

  • PDF

테라헤르츠 펄스 기술

  • Han, Hae-Ok;Yu, Nan-Lee;Jeon, Tae-In;Jin, Yun-Sik;Park, Ik-Mo;Kim, Jeong-Hoe;Mun, Gi-Won;Han, Yeon-Ho;Jeong, Eun-A;Gang, Cheol;Lee, Yeong-Rak;Go, Do-Gyeong;Lee, Ui-Su;Ji, Young-Bin;Kim, Geun-Ju;Han, Gyeong-Ho
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.87-103
    • /
    • 2008
  • In recent years, the field of THz photonics based on THz pulse technology has gained tremendous, world-wide interest as a new exciting research subject. With a possibility of many commercial applications as well as fundamental scientific achievements in the field, many advanced nations are stepping up their effort in advancing the field of THz photonics. This fact is supported by the observation of the significant increase in the number of papers on THz pulse technology presented in renowned international journals and conferences. The subject that is interesting for the THz application is the development of THz pulse sources and detectors, and other passive devices. In this paper, we present a brief review on some of the key devices and their relavant measurement techniques such as THz photoconductive antennas, optical rectification, difference frequency geneneration with quasi-phase matching structures, electro-optic sampling, high speed real time measurements, THz transmission lines, and other various waveguide structures.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

Growth of ZnS nanocluster thin films by growth technique and investigation of structural and optical properties (용액성장법(Solution growth technique)에 의한 ZnS nano 입자 박막성장 및 구조적, 광학적 특성)

  • 이종원;임상철;곽만석;박인용;김선태;최용대
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.3
    • /
    • pp.199-204
    • /
    • 2000
  • In this study, the ZnS nanosized thin films that could be used for fabrication of blue light-emitting diodes, electro-optic modulators, and n-window layers of solar cells were grown by the solution growth technique (SGT), and their structural and optical properties were examined. Based on these results, the quantum size effects of ZnS were systematically investigated. Governing factors related to the growth condition were the concentration of precursor solution, growth temperature, concentration of aq. ammonia, and growth duration. X-ray diffraction patterns showed that the ZnS thin film obtained in this study had the cubic structure ($\beta$-ZnS). When the growth temperature was $75^{\circ}C$, the surface morphology and the grain size uniformity were the best. The energy band gaps of samples were determined from the optical transmittance valued, and were shown to vary from 3.69 eV to 3.91 eV. These values were substantially higher than 3.65 eV of bulk ZnS, demonstrating that the quantum size effect of SGT grown ZnS is remarkable. Photoluminescence (PL) peaks were observed at the positions corresponding to the lower energy than that to energy band gap, illustrating that the surface states were induced by the ultra-fineness of grains in ZnS films. Particularly, for the first time, it is reported for the SGT grown ZnS that the PL peaks were shifted depending on the grain size.

  • PDF

An Optical True Time-Delay for Two-Dimensional X-Band Phased Array Antennas (2차원 X-밴드 위상 배열 안테나용 광 실시간 지연선로)

  • Jung, Byung-Min;Kim, Sung-Chul;Shin, Jong-Dug;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.287-294
    • /
    • 2005
  • In this paper, an optical true time-delay (TTD) for two-dimensional (2-D) phased array antennas (PAAs), composed of a multi-wavelength optical source and a fiber optic delay line matrix consisting of $2\times2$ optical switches with optical fiber connected between cross ports, has been proposed. A 2-bit $\times4-bit$ optical TTD for 10-GHz 2-D PAAs has been implemented by cascading a wavelength dependent TTD (WD-TTD) and a wavelength independent TTD (WI-TTD). The unit time delay for WD-TTD and WI-TTD have been chosen as ${\Delta}T=12ps$ and $\Delta\tau=6ps$, respectively. Time delay have been measured at all radiation angles. The maximum delay error for WD-TTD was measured to be 3 ps due to jitter incurred from gain switching. For the case of WI-TTD, error was within ${\pm}\;1\;ps$. The proposed optical TTD for a 2-D PAA has the following advantages: 1) higher gain compared to one-dimensional linear PAAs, 2) stabilization of optical power and wavelength by using a multi-wavelength optical source, and 3) fast beam scan and simple operation due to electronic control of the $2\times2$ optical switches matrix on a column-by-column basis.