• 제목/요약/키워드: electrical test

검색결과 7,387건 처리시간 0.032초

저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구 (A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices)

  • 길경석;송재용;문승보;차명수;황돈하;강동식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

A Test Input Sequence for Test Time Reduction of $I_{DDQ}$ Testing

  • Ohnishi, Takahiro;Yotsuyanagi, Hiroyuki;Hashizume, Masaki;Tamesada, Takeomi
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.367-370
    • /
    • 2000
  • It is shown that $I_{DDQ}$ testing is very useful for shipping fault-free CMOS ICs. However, test time of $I_{DDQ}$ testing is extremely larger than one of logic testing. In this paper, a new test input sequence generation methodology is proposed to reduce the test time of $I_{DDQ}$ testing. At first, it is Shown that $I_{DDQ}$ test time Will be denominated by charge supply current for load capacitance of gates whose output logic values are changed by test input vector application and the charge current depends on input sequence of test vectors. After that, a test input sequence generation methodology is proposed. The feasibility is checked by some experiments.riments.

  • PDF

기계학습 알고리즘을 이용한 반도체 테스트공정의 불량 예측 (Defect Prediction Using Machine Learning Algorithm in Semiconductor Test Process)

  • 장수열;조만식;조슬기;문병무
    • 한국전기전자재료학회논문지
    • /
    • 제31권7호
    • /
    • pp.450-454
    • /
    • 2018
  • Because of the rapidly changing environment and high uncertainties, the semiconductor industry is in need of appropriate forecasting technology. In particular, both the cost and time in the test process are increasing because the process becomes complicated and there are more factors to consider. In this paper, we propose a prediction model that predicts a final "good" or "bad" on the basis of preconditioning test data generated in the semiconductor test process. The proposed prediction model solves the classification and regression problems that are often dealt with in the semiconductor process and constructs a reliable prediction model. We also implemented a prediction model through various machine learning algorithms. We compared the performance of the prediction models constructed through each algorithm. Actual data of the semiconductor test process was used for accurate prediction model construction and effective test verification.

전기비저항과 암반등급의 상관관계에 대한 고찰 (A Study on the Correlation of Resistivity and Rock Quality)

  • 권형석;신중호;황세호;백환조;김기석;김종수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.81-88
    • /
    • 2001
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity is widely used in determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test in laboratory, such as uniaxial compressive strength(UCS), p wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity logging at in-situ area. Also we peformed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

물리탐사에 의한 터널구간의 암반등급 산정 (A Case Study for Rock Mass Classification using Geophysical Exploration)

  • 김기석;권형석;김종훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 암반역학위원회 학술세미나 논문집
    • /
    • pp.119-137
    • /
    • 2003
  • Electrical resistivity is one of physical property of the earth and measured by electrical resistivity survey, electrical resistivity logging and laboratory test. Recently, electrical resistivity Is widely used In determination of rock quality in road and railway tunnel design. To get more reliable rock quality data from electrical resistivity, it needs a lot of test and study on correlation of resistivity and rock quality. Firstly, we did rock property test In laboratory, such as uniaxial compressive strength(UCS), P wave velocity, Young's modulus and electrical resistivity. We correlate each test results and we found out that electrical resistivity has exponentially related to UCS and P wave velocity and linearly related to Young's modulus. And we accomplished electrical resistivity survey in field site and carried out electrical resistivity togging at In-situ area. Also we performed rock classification, such as RQD, RMR and Q-system and we correlate electrical resistivity to rock classification results. We found out that electrical resistivity logging data are highly correlate to RQD, Q and RMR. Also we found out that electrical resistivity survey data are lower than electrical resistivity logging data when there are faults or fractures. And it cause electrical resistivity survey data to lowly correlate to RQD, Q and RMR.

  • PDF

가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가 (Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings)

  • 조한구;김인성;안명상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

MMC 기반 HVDC 시스템용 서브모듈 시험회로의 커패시터 용량 분석 (Capacitance Value Analysis of Sub-module Test Circuit for MMC-based HVDC System)

  • 서병준;박권식;조광래;노의철;김흥근;전태원;김태진;이종필
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.433-439
    • /
    • 2018
  • This study considers the design of a submodule test circuit for the modular multi-level converter (MMC)-based HVDC systems. A novel submodule test circuit is proposed to provide not only an AC but also a DC component to the submodule current. However, the current waveforms depend on the capacitor voltages. Therefore, determining the capacitance value of the test circuit is important. Finding a proper capacitance value is easy when the proposed analysis method is used. Simulation and experimental results show the usefulness of the proposed method.

Polyethylene 계열 절연재료의 환경적·기계적 특성 (Wet Environmental and Mechanical Characteristics for Polyethylene-based Insulating Materials)

  • 송우창;최원석;박하용
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.119-123
    • /
    • 2014
  • In this study, four kinds of specimens of PE(polyethylene)-based insulating materials were prepared for selecting the optimum insulation materials in a wet environment. The specimens were tested by various methods, the anti tracking test, the transmittance test in the water vapor transmittance(WVT) and the abrasion resistive test, etc. The HDPE(high-density polyethylene) specimen was showed excellent property in the tracking resistance test and the lowest transmittance in water vapor transmittance test. In the abrasion resistive test, the LLDPE(linear low-density polyethylene) and MDPE(medium-density Polyethylene) were showed excellent mechanical properties. The value of cut-through resistance for MDPE and HDPE were superior to that for LLDPE and LDPE(low-density polyethylene).

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.