Optimal Calculation Method of Distribution Loss in Distribution Systems

  • Rho Dae-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.109-115
    • /
    • 2005
  • Recently, the needs and concerns regarding power loss have been increasing according to energy conservation at the level of the national policies and the business strategies of power utilities. In particular, the issue of power loss is the main factor for determining rates for electrical consumption in the deregulation of the electrical industry. However, because of the lack of management for power loss load factors (LLF) it is difficult to make a calculation for power loss and to make a decision concerning the electric rates. Furthermore, loss factor (k-factor) in Korea, which is of primary significance in the calculation of distribution power loss, has been used as a fixed value of 0.32 since the fiscal year 1973. Therefore, this study presents the statistical calculation methods of the loss factors classified by load types and seasons by using the practical data of 65 primary feeders that have been selected by appropriate procedures. Based on the above, the algorithms and methods, as well as the optimal method of the distribution loss management classified by facilities such as primary feeders, distribution transformers and secondary feeders is presented. The simulation results demonstrate the effectiveness and usefulness of the proposed methods.

함수계와 비수계 ER유체의 온도-점도 특성 (Temperature-Viscosity Characteristics of Hydrous and Anhydrous Electro-Rheological Fluids)

  • 이진우;장성철;염만오;김도태;박재범
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.451-456
    • /
    • 2002
  • This paper describes the properties of Temperature-Viscosity characteristics of hydrous and anhydrous ER fluids containing starch and titanium particle in silicone oil. ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed in the electrically insulating silicone oil induced when electric field is applied. ER fluids under electric field have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured on the couette cell type rheometer as a function of electric fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electric field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200/equation omitted/ in 2 minutes.

  • PDF

하이브리드 전기자동차용 리튬이온 배터리 모델링 및 상태 관측기 설계 (Modeling and State Observer Design of HEV Li-ion Battery)

  • 김호기;허상진;강구배
    • 전력전자학회논문지
    • /
    • 제13권5호
    • /
    • pp.360-368
    • /
    • 2008
  • 하이브리드 전기자동차용 리튬이온 배터리 시스템의 모델링 및 모델기반 상태 관측기 설계에 관한 연구를 수행하였다. 배터리의 동적 특성을 모사하기 위한 모델은 전기적 등가회로로 단순화하여 제안하였다. 모델 파라미터는 최소 자승 이론에 의거 다양한 운전조건에 따라 추정하였고, 실험 검증하였다. 검증된 모델을 기반으로 하는 비례-적분(PI) 제어의 상태 관측기를 구성하였고, 제어 이득 선정방법을 제안하였다. 제안된 상태 관측기의 강인성은 시뮬레이션 및 실험에 의거 다양한 운전조건 변동에 따른 민감도를 분석하여 검증하였다.

Effect of Anodic Gas Compositions on the Overpotential in a Molten Carbonate Fuel Cell

  • Lee C.G.;Kim D.H.;Hong S.W.;Park S.H.;Lim H.C.
    • 전기화학회지
    • /
    • 제9권2호
    • /
    • pp.77-83
    • /
    • 2006
  • Anodic overpotential has been investigated with gas composition changes in a $100cm^2$ class molten carbonate fuel cell. The overpotential was measured with steady state polarization, reactant gas addition (RA), inert gas step addition (ISA), and electrochemical impedance spectroscopy (EIS) methods at different anodic inlet gas compositions, i.e., $H_2:CO_2:H_2O=0.69:0.17:0.14\;atm\;and\;H_2:CO_2:H_2O=0.33:0.33:0.33\;atm$, at a fixed $H_2$ flow rate. The results demonstrate that the anodic overpotential decreases with increasing $CO_2\;and\;H_2O$ flow rates, indicating the anode reaction is a gas-phase mass-transfer control process of the reactant species, $H_2,\;CO_2,\;and\;H_2O$. It was also found that the mass-transfer resistance due to the $H_2$ species slightly increases at higher $CO_2\;and\;H_2O$ flow rates. EIS showed reduction of the lower frequency semi-circle with increasing $H_2O\;and\;CO_2$ flow rate without affecting the high frequency semi-circle.

화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증 (Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack)

  • 신동호;김영훈;서현수;홍기정;김학준;김용진;한방우;이가영;천성남;황정호
    • 한국입자에어로졸학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

발전소 주변해역 식물플랑크톤의 군집 특성 (Characteristics of Phytoplankton Communities in the Coastal Waters of Power Plant)

  • 강연식
    • ALGAE
    • /
    • 제23권1호
    • /
    • pp.31-52
    • /
    • 2008
  • This study analyzes characteristics of phytoplankton communities around Wolseong nuclear power plant by selecting 16 stations from July 2006 to June 2007 and understands the influences on standing crops and chlorophyll a of phytoplankton by passing through the cooling water system. The total species number is 283, among which diatoms is 208 occupying 73.5% of total taxa. The mean of total standing crops is 469,380-3,704,114 cells L-1. It is the highest in April 2007 because blooming of Chaetoceros socialis occurs during this period. The mean standing crops of microplankton and nanoplankton are average 129,666-3,392,640 cells L-1 and 240,943-650,505 cells L-1 respectively, which occupy 54.01% and 46.54% of total standing crops. The mean concentrations of total chlorophyll a is 0.64-5.39 μg L-1. The mean concentrations of chlorophyll a of microplankton, nanoplankton and picoplankton are 1.33 μg L-1, 0.21 μg L-1 and 0.49 μg L-1 respectively. Dominant species around Wolseong neclear power plant during this study are Chaetoceros debilis, Chaetoceros socialis, Leptocylindrus danicus, Pseudo-nitzschia fraudulenta, P. subfraudulenta and Thalassiosira decipiens. Fluctuation rates of standing crops and chlorophyll a concentrations of phytoplankton passing through the cooling water system are 22.80% and 50.48% respectively. Decrease of standing crops and chlorophyll a concentrations of phytoplankton means that community structure of phytoplnakton may change at the discharge areas.

거대 점 오염원의 플룸에 의한 시정 장애 효과 연구 (A Study on Visibility Impairment Impact of the Plume from a Vast Point Source)

  • 배주현;김유근
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.599-611
    • /
    • 1999
  • Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.

  • PDF

대구지역(大邱地域) 지각(地殼) ${\gamma}$-선(線)의 조사선량율(照射線量率) 측정(測定) (A Measurement of the Exposure Rates by Terrestrial y-rays in Taegu Area)

  • 장시호;정춘균;강희동;이모성;최문규;김위수
    • Journal of Radiation Protection and Research
    • /
    • 제19권2호
    • /
    • pp.121-132
    • /
    • 1994
  • 본 연구는 대구지역의 지각 ${\gamma}$-선에 의한 조사선량율을 측정하고 그에 따른 성분별 공간선량율 및 지역적 분포 등의 환경방사선 특성을 조사하였다. ${\gamma}$-선 스펙트럼의 측정에는 $4^{'}{\phi}{\times}4^{'}$ NaI(T1) 계측기와 휴대용 다중파고분석장치를 이용하여 이 지역내의 28개 지점에서 in-situ spectrometry를 수행하였으며, 측정된 스펙트럼으로부터 조사선량율을 환산하여 지각 ${\gamma}$-선의 총선량율과 일반적으로 자연방사능의 주종이 되는 $^{40}K,\;^{238}U$ 계열 및 $^{232}Th$계열의 성분별 조사 선량율을 구하였다. 조사결과 대구지역의 지각 ${\gamma}$-선에 의한 평균조사선량율은 $9.4{\mu}R/h$였으며 지점별 분포는 $7.6{\sim}11.0{\mu}R/h$ 범위로 다소 차이를 보였다. 측정시에 수반되는 기후나 우주선 등에 따른 일 변화폭을 고려한다면 지점간의 차이는 주로 표토층의 자연방사성핵종인 $^{40}K,\;^{238}U$계열 및 $^{232}Th$ 계열의 핵종에 기인함을 알 수 있었으며, 성분별 선량율은 $^{40}K\;2.9{\sim}4.6{\mu}R/h,\;^{238}U$ 계열 $1.2{\sim}3,\;1{\mu}R/h,\;^{232}Th$ 계열 $2.5{\sim}5.0{\mu}R/h$의 분포를 나타냈다.

  • PDF

Electrorheological Behavior of the Hollow PANI Sebacate Suspension upon Application of the Electric Field

  • Choi, Ung-Su;Lee, Sang-Soon
    • KSTLE International Journal
    • /
    • 제10권1_2호
    • /
    • pp.13-16
    • /
    • 2009
  • The electrorheological(ER) behavior of hollow polyaniline(PANI) sebacate suspension in silicone oil was investigated by varying the electric fields and shear rates, respectively. The hollow PANI sebacate susepnsion acted as a typical Bingham fluid caused by the polarizability of an amide polar group and showed shear yield stress due to the formation of chains upon application of an electric field. The shear stress for the hollow PANI sebacate suspension exhibited an electric field power of 1.24. On the basis of the experimental results, the newly synthesized hollow PANI sebacate suspension was found to be an anhydrous ER fluid.

경쟁체제 도입시 주택용 전기요금개선에 관한 연구 (A Study of Restructured Residential Electricity Pricing toward the Competitive Power Market)

  • 김민정
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.889-895
    • /
    • 2014
  • Korea electric power industry had been under vertical monopoly but is typically getting restructured for free competition. An ideal pricing system under the competitive market system is 'unbundled pricing system' and 'marginal pricing system', but the current pricing system still adheres to the traditional bundled system and the average cost pricing system. Especially, progressive electricity rates for residential use reflect governmental policy-making which is focused on income redistribution & welfare, industrial supports and energy saving. This study proposes new and reasonable residential electricity pricing systems which are Time-Of-Use (TOU) and Real-Time Pricing (RTP) to reflect variations in the wholesale price of electricity. It also presents examples of various tariffs for residential electricity pricing systems.