• 제목/요약/키워드: electric power rates

검색결과 206건 처리시간 0.033초

장애인을 위한 스마트 모빌리티 시스템 개발 (Development of Smart Mobility System for Persons with Disabilities)

  • 유영준;박세은;안태준;양지호;이명규;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권4호
    • /
    • pp.97-103
    • /
    • 2022
  • Low fertility rates and increased life expectancy further exacerbate the process of an aging society. This is also reflected in the gradual increase in the proportion of vulnerable groups in the social population. The demand for improved mobility among vulnerable groups such as the elderly or the disabled has greatly driven the growth of the electric-assisted mobility device market. However, such mobile devices generally require a certain operating capability, which limits the range of vulnerable groups who can use the device and increases the cost of learning. Therefore, autonomous driving technology needs to be introduced to make mobility easier for a wider range of vulnerable groups to meet their needs of work and leisure in different environments. This study uses mini PC Odyssey, Velodyne Lidar VLP-16, electronic device and Linux-based ROS program to realize the functions of working environment recognition, simultaneous localization, map generation and navigation of electric powered mobile devices for vulnerable groups. This autonomous driving mobility device is expected to be of great help to the vulnerable who lack the immediate response in dangerous situations.

Dimmer 회로에서의 고조파 발생과 저감에 관한 연구 (A Study on harmonics generation and reduction in Dimmer circuits)

  • 박석훈;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.252-254
    • /
    • 2000
  • For many years, electric utility has used sustained interruption rates as a reliability index. Today, however, many electricity consumers are adversely affected by more subtle voltage disturbances such as harmonic distortion. This paper deals with observations of events that occur in the Dimmer circuits and phase control which could affect harmonics problem to the commercial power system. In order to reduce the effect of harmonics and design filters, Solid State Relay Dimmer(SCRs or TRIACs) and Noise Filter are described, and the effects of harmonics is also analyzed. IGBT Dimmer which is appropriate method to reduce harmonics and improve efficiency is introduced.

  • PDF

SF6계 혼합가스의 뇌임펄스 절연파괴특성 (Lightning Impulse Breakdown Characteristics of SF6-based Mixture Gases)

  • 서호준;이동희
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.675-681
    • /
    • 2005
  • $SF_6$ is widely used as gas insulation medium because of having excellent dielectric and arc-quenching properties. However the use of it is getting to be suppressed from the viewpoint of mitigating global warming. For the development of environmentally-benign electric power equipment and system, novel gases or mixture gases are strongly required as the substitute of $SF_6$ gas. In this study the authors constructed an experimental system to investigate insulation properties of the mixed gases composed of negative $gas(SF_6)$ and electron deceleration gases$(N_2\;and\;CO_2)$. Breakdown and prebreakdown characteristics of $SF_6/N_2/CO_2$ mixture gases were investigated using the above mentioned system for different rates and gas pressures.

Full 밴드 몬테칼로 시뮬레이션을 이용한 GaAs 임팩트이온화에 관한 연구 (Impact ionization for GaAs using full band monte carlo simulation)

  • 정학기
    • 전자공학회논문지A
    • /
    • 제33A권11호
    • /
    • pp.112-119
    • /
    • 1996
  • Impact ionization model in GaAs has been presented by modified keldysh formula with two sets of power exponent of 7.8 and 5.6 in study. Impact ionization rate is derived from fermil's golden rule and ful lenergy band stucture based on empirical pseudopotential method. Impact ionization rates show anisotropic property in low energy region (<3eV), but isotropic in high energy region (3>eV). Full band monte calo simulator is coded for investigating the validity of the GaAs impact ionization model, and validity is checked by comparing impact ionization coefficients with experimental values and ones in anisotropic model. Valley transitions to energy alteration are explained by investigating electron motion in brillouin zone for full band model to electric field variation.

  • PDF

뇌서지로 인한 피뢰기 열화시 과도상태 분석 (Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge)

  • 임성용;김규호;이상봉;김수배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

형광등 Positive column에 대한 자장인가 효과 (Magnetic field effect on the positive column of fluorescent lamp)

  • 지철근;김창종
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Mold transformer)

  • 조한구;이운용;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

Failure simulation of nuclear pressure vessel under severe accident conditions: Part I - Material constitutive modeling

  • Eui-Kyun Park;Ji-Su Kim;Jun-Won Park;Yun-Jae Kim;Yukio Takahashi;Kukhee Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4146-4158
    • /
    • 2023
  • This paper proposes a combined plastic and creep constitutive model of A533B1 pressure vessel steel to simulate progressive deformation of nuclear pressure vessels under severe accident conditions. To develop the model, recent tensile test data covering a wide range of temperatures (from RT to 1,100 ℃) and strain rates (from 0.001%/s to 1.0%/s) was used. Comparison with experimental data confirms that the proposed combined plastic and creep model can well reflect effects of temperature and strain rate on tensile behaviour up to failure. In the companion paper (Part II), the proposed model will be used to simulate OECD lower head failure (OLHF) test data.

농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례 (Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well)

  • 송성호;이병선;안중기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권4호
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.

브롬화된 Polysulfone막에 의한 기체 투과 특성에 관한 연구 (Gas Permeation Properties of Brominated Polysulfone Membranes)

  • 임지원;이보성;김태영;김대훈;이병성;윤석원;임현수
    • 멤브레인
    • /
    • 제19권2호
    • /
    • pp.150-156
    • /
    • 2009
  • Polysulfone막의 효율을 향상시키기 위하여 막에 브롬화 시킨 후 막의 구조 및 기체투과 특성에 대해 연구하였다. 막의 특성은 FT-IR, 1H-NMR, TGA, Contact angle 등을 사용하여 조사하였고, 브롬화된 막의 기체투과 특성을 알아보기 위해 He, $N_2,\;CO_2,\;O_2$를 사용하였다. 브롬화된 Polysulfane막의 기체투과결과 브롬의 양이 증가할수록 투과도는 감소하고 투과 선택도는 증가하는 결과를 얻을 수 있었다. 그 중 질소는 불소화에 따라서 가장 큰 영향을 받아 투과도가 최고 36%까지 낮아지는 결과를 나타내었으며, 이산화탄소에 대한 질소의 투과선택도는 15% 이상의 매우 향상된 결과를 나타내었다.