• 제목/요약/키워드: electric power rates

검색결과 206건 처리시간 0.026초

전류제어를 이용한 등기구 전원장치에 관한 연구 (A Study of Lighting Flxtures Power Supply That Use Current Control)

  • 이병선;김영선
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.199-204
    • /
    • 2012
  • 지지구 온난화 등과 관련하여 에너지 개발과 절약에 대한 연구가 활발하다. 본 연구에서는 전체 전기에너지 사용의 19%를 차지하는 조명기구 소비전력의 효율적인 절감과 수명연장을 위해 주파수변조와 펄스폭 변조를 혼용한 전류제어 방식의 새로운 형태인 하프브리지형 전원장치를 제안한다. 제안한 전원장치가 갖는 우수성과 안정성에 대해 입증하고 그 특성을 분석 하였다.

A Reliability Evaluation Model for the Power Devices Used in Power Converter Systems Considering the Effect of the Different Time Scales of the Wind Speed Profile

  • Ji, Haiting;Li, Hui;Li, Yang;Yang, Li;Lei, Guoping;Xiao, Hongwei;Zhao, Jie;Shi, Lefeng
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.685-694
    • /
    • 2016
  • This paper presents a reliability assessment model for the power semiconductors used in wind turbine power converters. In this study, the thermal loadings at different timescales of wind speed are considered. First, in order to address the influence of long-term thermal cycling caused by variations in wind speed, the power converter operation state is partitioned into different phases in terms of average wind speed and wind turbulence. Therefore, the contributions can be considered separately. Then, in regards to the reliability assessment caused by short-term thermal cycling, the wind profile is converted to a wind speed distribution, and the contribution of different wind speeds to the final failure rate is accumulated. Finally, the reliability of an actual power converter semiconductor for a 2.5 MW wind turbine is assessed, and the failure rates induced by different timescale thermal behavior patterns are compared. The effects of various parameters such as cut-in, rated, cut-out wind speed on the failure rate of power devices are also analyzed based on the proposed model.

전기뱀장어의 전기발생을 모사한 고전압 액체 전해질 미소전지 (High-Voltage Liquid-Electrolyte Microbatteries Inspired from Electric Eels)

  • 김문철;조영호
    • 대한기계학회논문집A
    • /
    • 제33권5호
    • /
    • pp.469-473
    • /
    • 2009
  • We present high-voltage liquid-electrolyte microbatteries, inspired from the high-voltage generation mechanism of electric eels using serially connected multiple-cell arrays. In the microbatteries, we purge air into the electrolyte filled in a channel layer to isolate serially connected multiple cell arrays using three surface-tension valves (cell-front, outlet, and cell-end valves). Compared to the previous multi-cell stack or interconnection, present microbatteries provide a reduced multi-cell charging time. We have designed and characterized four different prototypes C1, C10, C20, and C40 having 1, 10, 20, and 40 cells, respectively. In the experimental study, the threshold pressures of cell-front, outlet, and cell-end valves were measured as $460{\pm}47$, $1,000{\pm}53$, and $2,800{\pm}170$ Pa, respectively. The average charging time for C40 was measured as $26.8{\pm}4.9$ seconds where the electrolyte and air flow-rates are 100 and $10{\mu}l/min$, respectively. Microbatteries showed the maximum voltage of 12 V (C40), the maximum power density of $110{\mu}W/cm^2$ (C40), and the maximum power capacity of $2.1{\mu}Ah/cm^2$ (C40). We also proposed a tapered-channel to remove the reaction gas from the cell chamber using a surface tension effect. The present microbatteries are applicable to high-voltage portable power devices.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.

FTA를 이용한 수변전설비의 최소절단집합 도출 (Minimal Cut Set of Electric Power Installations using Fault Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.41-46
    • /
    • 2017
  • In this paper, from making an electrical fire which is thought to be the most damaging among potential dangers as a top event, minimal cut sets (MCS) about it were analyzed. For this, components of a power substation were classified into 15 items. Failure rates and modes were extracted based on Korea Electrical Safety Corporation, IEEE Gold Book, and RAC. To analyze the top event (an electrical fire), main events were assorted into "safety devices for overcurrent" and "ampere meter of detecter". Failure of components was divided into failure of VCB, COS, and MCCB. A fault tree was composed of 3 AND gate, 5 OR gates and 17 basic events. Overlapped events among the basic events are things which occur from relevant components. They were attached to the tree by distinguishing identifiers. In case of FT, two minimal cut sets of "IO_METER", "MF_METER", "DO_MCCB" and "IO_METER", "MF_METER", "DO_VCB" take 46% of electrical fires. Therefore, about basic events which are included in the top two minimum cut sets, strict control is necessary.

EV용 이동형 전원공급장치의 구현 및 경제성 평가에 관한 연구 (Implementation and Economic Evaluation of Movable Power Supply Device for Electric Vehicle)

  • 최성문;한병길;이후동;김미영;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.77-86
    • /
    • 2020
  • 기존의 고정형 EV(electric vehicle) 충전기는 이용률이 증가하게 되면 충전 인프라 설비 부족으로 인해 사용자의 충전 대기시간이 길어지는 불편함이 발생할 수 있고, EV 충전기를 증설하는 경우, 배전선로(지중) 증설비용 및 선로의 전압강하로 인한 전력품질 문제가 발생할 수 있다. 따라서, 본 논문에서는 상기의 문제점을 해결하고, EV 충전기 부족으로 인한 불편함을 해결할 수 있는 EV용 이동형 전원공급장치(movable power supply device, MPSD)를 제안한다. 제안한 MPSD는 태양광전원부, 에너지저장부, EV용 충전기부, 감시제어부로 구성되고, 사용자의 환경요소에 따라 MPSD를 유연하게 이용할 수 있도록 3가지 운용모드로 나눌 수 있다. 또한, 경제성 평가 모델링을 비용요소와 편익요소로 구분한다. 여기서, MPSD의 비용요소로는 태양광전원부, 에너지저장부, EV 충전기부, 감시제어부의 설비비용과 기존의 EV 충전기 설비비용, 배전선로 증설비용, 기존의 EV 충전기 운용비용등의 편익요소로 구성되며, 이를 바탕으로 현재 가치 환산법을 사용하여 경제성을 평가한 결과, MPSD가 기존의 고정형 EV 충전기보다 유리함을 알 수 있었고, 설치지점의 거리에 따라 편익이 크게 좌우함을 확인하였다.

케미컬루핑 연소시스템을 위한 산소전달입자의 상온-상압 고체순환특성 (Solid Circulation Characteristics of Oxygen Carrier for Chemical Looping Combustion System at Ambient Temperature and Pressure)

  • 윤주영;김하나;김정환;이도연;백점인;류호정
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.384-391
    • /
    • 2017
  • Effects of operating variables on solid circulation rate were measured and discussed using two-interconnected circulating fluidized bed system at ambient temperature and pressure. OCN 706-1100 particles were used as oxygen carrier. The measured solid circulation rates increased as the lower loop seal gas flow rates and the solid height in the fuel reactor increased. Suitable operating conditions to avoid choking of the air reactor were confirmed. Continuous long-term operations of steady-state solid circulation were also demonstrated at two different conditions based on the operating window.

Emissions of Volatile Organic Compounds from a Swine Shed

  • Osaka, Nao;Miyazaki, Akane;Tanaka, Nobuyuki
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권2호
    • /
    • pp.178-191
    • /
    • 2018
  • The concentrations and chemical compositions of volatile organic compounds (VOCs), including volatile fatty acids, phenols, indoles, aldehydes, and ketones, which are the main organic compounds generated by swine, were investigated in July and October 2016 and January 2017. In addition, the emission rates and annual emissions of these components from the swine shed were estimated. The concentrations of VOCs in the swine shed averaged $511.3{\mu}g\;m^{-3}$ in summer, $315.5{\mu}g\;m^{-3}$ in fall and $218.6{\mu}g\;m^{-3}$ in winter. Acetone, acetic acid, propionic acid, and butyric acid were the predominant components of the VOCs, accounting for 80-88% of the total VOCs. The hourly variations of VOC concentrations in the swine shed in fall and winter suggest that the VOC concentrations were related to the ventilation rate of the swine shed, the activity of the swine, and the temperature in the swine shed. Accordingly, the emission rates of VOCs from the swine shed were $1-2{\times}10^3{\mu}g(h\;kg-swine)^{-1}$.

그래핀 플레이크 크기에 따른 전기 이중층 커패시터용 전극의 전기화학적 특성 (Electrochemical Properties of EDLC Electrodes with Diverse Graphene Flake Sizes)

  • 유혜련
    • 한국전기전자재료학회논문지
    • /
    • 제31권2호
    • /
    • pp.112-116
    • /
    • 2018
  • Electric double layer capacitors (EDLCs) are promising candidates for energy storage devices in electronic applications. An EDLC yields high power density but has low specific capacitance. Carbon material is used in EDLCs owing to its large specific surface area, large pore volume, and good mechanical stability. Consequently, the use of carbon materials for EDLC electrodes has attracted considerable research interest. In this paper, in order to evaluate the electrochemical performance, graphene is used as an EDLC electrode with flake sizes of 3, 12, and 60 nm. The surface characteristic and electrochemical properties of graphene were investigated using SEM, BET, and cyclic voltammetry. The specific capacitance of the graphene based EDLC was measured in a 1 M $TEABF_4/ACN$ electrolyte at the scan rates of 2, 10, and 50 mV/s. The 3 nm graphene electrode had the highest specific capacitance (68.9 F/g) compared to other samples. This result was attributed to graphene's large surface area and meso-pore volume. Therefore, large surface area and meso-pore volume effectively enhances the specific capacitance of EDLCs.

원격플라즈마화학증착에 의한 투명전도성 산화주석 박막 (The transparent and conducting tin oxide thin films by the remote plasma chemical vapor deposition)

  • 이흥수;윤천호;박정일;박광자
    • 한국진공학회지
    • /
    • 제7권1호
    • /
    • pp.43-50
    • /
    • 1998
  • 원격플라즈마화학증착(RPCVD)에 의하여 파이렉스 유리 기판 위에 투명전도성 산화 주석막을 제조하였다. RPCVD공정의 주요한 조절변수는 증착시간, 사메틸주석, 산소 및 아 르곤의 유속, 라디오 주파수 출력, 및 기판온도를 포함했다. 양질의 산화주석막을 제조하고 RPCVD공정을 보다 잘 이해하기 위하여 이들 파라미터에 대한 증착속도, 전기적 저항, 광 학적 투과도 및 결정구조의 의존성을 체계적으로 살펴보았다. 산화주석막의 성질에 미치는 이들 파라미터의 영향은 복잡하게 서로 연관되어 있다. 최적화된 증착조건에서 제조된 산화 주석막은 102$\AA$/min의 증착속도, $9.7\times 10^{-3}\Omega$cm의 비저항 및 ~80%의 가시선 투과도를 나 타냈다.

  • PDF