• Title/Summary/Keyword: electric potential

Search Result 1,335, Processing Time 0.028 seconds

Grounding Characteristic Analysis of Plate Electrodes

  • Kim, Sung-Sam;Kim, Ju-Chan;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2007
  • In this study, an experiment on the efficient construction method of plate electrodes, the influence of electric potential interference in plate electrodes, and building foundations were explored. The experimental result of the electric potential measurement was taken on the basis of the direction of movement and the condition in which the plate electrodes are laid underground in building foundations. It shows that the construction method of laying the plate electrodes vertically exhibits a more efficient reduction of electric potential in a diagonal direction and on an X axis than laying plates horizontally. For plate electrode construction in an area that has uniform conditions, the parallel joint construction method is more effective than a single construction to reduce earth electrical potential and ground resistance. In addition, a straight arrangement performs well in ground efficiency, compared to the parallel arrangement.

The Effects of Electric Field Variation by The Third Electrode on Water Electrophysicochemical Characteristics (제3전극에 의한 전계변화가 수중 전기물리화학적 특성에 미치는 영향)

  • Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.136-141
    • /
    • 2010
  • In this paper, after the third electrode type oxidant generator which could format non-uniform electric field in water had been manufactured and installed, by direct electrolysis, the effects of the hydrogen potential and oxidation reduction potential characteristics attendant upon electric field change on a higher concentration oxidant generation characteristics were investigated. Consequently, as the third electrode was installed in the middle of two slit electrodes and the polarity of applied power was changed, it was observed that the third electrode system with the positive electrode can generate a higher concentration oxidant, hydrogen potential and oxidation reduction potential as compared with that of the negative electrode. It is because the positive electrode was bombarded mostly energetic electrons and the negative electrode was bombarded mainly by less energetic positive ions.

Calculation of Electric Potential Rise of Horizontal Grounding Electrode Caused by Lightning Stroke Currents (뇌격전류에 의한 수평접지극의 전위상승 계산)

  • Lee, Bok-Hee;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.81-86
    • /
    • 2013
  • An electric potential rise of the grounding electrode developed by the lightning stroke currents should be calculated for the purpose of effective protection of electrical and electronic equipment. In this paper, the electromagnetic model was applied to calculate the harmonic impedance of grounding electrode. Also the empirical equation related to the permittivity and resistivity of soil was used. The lightning current waveforms, which are expressed by the Heidler's equation, were used in order to calculate accurately transient electric potential rises. The transient voltage was obtained by using the simulated harmonic impedance and the lightning current in frequency domain. Finally, the transient voltages of horizontal grounding electrode(10m) under lightning stroke currents were calculated by IFFT(Inverse Fast Fourier Transform).

A study of nano-scale electrical discharge characteristics for automotive sensor applications

  • Choi, Hae-Woon;Han, Man-Bae
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.235-238
    • /
    • 2009
  • To study the relationship between spark ignition and the gap in the nano-scale region, the electric potential was applied to between a Pt-Ir tip and a gold substrate. The tip was sharpened by electro-chemical etching process in the solution of $CaCl_2;H_2O$ and acetone. The radius of tip was measured to be around 200nm and attached to the scanning probe microscope to control the gap between the tip and the substrate. The electric potential of 10V to 80V was applied to initialize the spark. The gaps and the current profile were measured to analyze the characteristics of spark ignition. A spark sustaining time was measured to be between 50ns and 200ns depending on the applied electric potential and the gap between the electrodes. The continuous electric discharge was successfully sustained up to 1 second of spark or arc time. The developed process can be applicable to the micro-scale fabrication of automotive sensors as a similar concept of GTAW.

  • PDF

Electric Shock Risk Assessment of the Human Body and Potential Distribution Analysis by FLUX3D in a Public Bathtub (공중욕조에서의 FLUX3D에 의한 전위분포 해석 및 인체의 전격위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kim, Han-Sang;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.41-46
    • /
    • 2007
  • This paper considers the electrical shock risk of the human body due to underwater leakage current in such places of public baths. Many submerged electric facilities in a public bath may create a severe electric shock hazard for the human body, since wet body in an accidentally energized bathtub can result in low electrical resistance through the human body for leakage or fault currents. Therefore a major consideration, in the context of electrical safety underwater, is the shock risk to the bather as a result of electric current flowing through the water in bathtub. To assess the electric shock risk and to analyze the potential distribution in a bathtub, 2 different situation cases are set up, then experimental and simulation methods are adopted. The validity of 2 cases of simulation and experiment data in a bathtub for electric distribution underwater are compared and analyzed. Also electric shock risk assessment underwater in a real public bathtub by simulation program package, Flux 3D, was conducted herein, and the results are presented and discussed.

Differences in electric potential of meridian system(4) -Comparing electrical potentials of healthy volunteers between two measurements- (정상인의 경락전위측정 실험에 대한 연구(4) -측정방법에 따른 정상인의 경락전위 비교를 중심으로-)

  • Choi Hwan-Soo;Nam Bong-Hyun
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.151-160
    • /
    • 2001
  • Objective : Assuming that the characteristic of meridian system has been similar to this of electric potentials in human body and that measurements of electric potential at well(井穴) and sea(合穴) points in branches of the twelve meridians will be representative of measurements of the twelve meridians, to measure the electric potentials in twenty aged and fifty aged healthy volunteers groups at sleeping(SG) and awakening(AG), and then to find out the characteristic of meridian system among 2 groups. Methods : We selected who thirty healthy volunteers were diagnosed by a blood test, urine examination and differentiation of syndromes by five viscera(五臟辨證) among volunteers. Their electric potential of well and sea points in the meridians were simultaneously measured by physiograph. Results : Measurements were analyzed by statistical factor analysis, we obtained that the both left and right side electric potential of well and sea points in branches of the twelves meridians were unclearly divided into four factors according to age and whether sleeping or not, which were the three Yin meridians of the hand, the three Yang channels of the hand, the three Yin meridians of the foot, and the three Yin meridians of the foot. Conclusion : In conclusion, using the sequently measuring method, we obtained that electrical potentials of well and sea points in branches of the twelves meridians were divided into two factors, but the simultaneously measuring method, those were divided into four factors. The latter result means that the electrical potentials of twelve meridians were reflected by the function of the viscera and bowels.

  • PDF

A Simulation Modeling for Rail Potential and Leakage Current Analysis in DC Traction System (직류 전기철도에서의 레일전위 및 누설전류 해석을 위한 시뮬레이션 모델링)

  • Yoon, Yim-Joong;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.196-201
    • /
    • 2008
  • In DC traction systems, a part of feedback current returning through rails becomes leakage current, illumination on a metal laid underground results from the leakage current to ground. To prevent the leakage current on rails, feedback rails almost have insulated with the ground. Insulation between rails and the ground causes that the earth method changes a isolated method in DC traction systems. the rail potential rise results in the isolated method. the rail potential rise causes an electric shock when a person touches the ground and rolling stock. To decrease the rail potential rise and leakage current, there are methods for reducing the feedback resistance and current of rails, increasing the leakage resistance, decreasing the distance between substations. But it are necessary to forecast and analyze the rail potential and amplitude of leakage current. In this paper, we modeled DC traction systems and feedback circuit to simulate the rail potential and amplitude of leakage current using PSCAD/EMTDC that is power analysis program, forecasted the rail potential and amplitude of leakage current about changing various parameters in the electric circuit. By using the simulation model, we easily will forecast the rail potential and amplitude of leakage current in case of a level of basic design and maintenance in electric railway systems, valuably use basic data in case of system selection.

  • PDF

Development of DSM Potential Evaluation Procedures and Algorithm (DSM 잠재량 평가절차 및 알고리즘 개발)

  • Rhee, Chang-Ho;Park, Jong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.917-919
    • /
    • 1997
  • Recently, electric industry confront a strategical change and high competiveness environment in the course of deregulation. Especially, rapid growth in electricity demand, financial need for new power plant construction, and environmental problems have led to search for more efficient energy production and energy conservation technologies in Korea. Due to the potential energy and cost savings, DSM(Demand-Side Management) plays and important role in the electric resource planning. In this paper, we suggest DSM potential evaluation procedures and algorithm. Also, we present screening analysis methods for DSM potential evaluation.

  • PDF

Differences in electric potential of meridian system -Comparing electrical potentials of patients with Lumbago due to strain and contusion- (좌섬요통 환자의 12경맥 전위측정 연구)

  • Choi, Hwan-soo;Nam, Bong-hyun
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.101-111
    • /
    • 2004
  • Objective : Assuming that the characteristic of meridian system has been similar to this of electric potentials in human body and that measurements of electric potential at well(井穴) and sea (合穴) points in branches of the twelve meridians(WSBTM) will be representative of measurements of the twelve meridians, to measure the electric potentials of 13 patients with Lumbago due to strain and contusion(좌섬요통<挫閃腰痛>, LSC), to find out the characteristic of meridian system in patients with LSC. Methods : Electric potentials of well and sea points in the meridians in twenty one patients with the pain in the lion diagnosed as LSC were repeatedly measured by physiograph(PowerLab). Measurements of those electrical potentials were analyzed by factor analysis. Results : The electric potentials of WSBTM at the left side were divided into four factors. On the other hand those at the right side Were divided into four factors. Conclusion : In conclusion, their electrical potentials at the left and right side were factors which are different from each side. Thus electrical potentials of well and sea points might be the representative meridian to show their characteristics.

  • PDF

Differences in Electric Potential of Meridian System(6) -Comparing electrical potentials of patients with waist lesions- (요각통 환자의 12 경맥 전위측정 연구(6))

  • Nam, Bong-Hyun;Choi, Hwan-Soo
    • Korean Journal of Oriental Medicine
    • /
    • v.8 no.2 s.9
    • /
    • pp.85-93
    • /
    • 2002
  • Objectives:Assuming that the characteristic of meridian system has been similar to that of electric potentials in human body and that measurements of electric potential at well(井穴) and sea(合穴) points in branches of the twelve meridians(WSBTM) will be representative of measurements of the twelve meridians, to measure the electric potentials of 17 patients with loin lesions, and pain of loin and lower extremities (腰脚痛, LWLE), to find out the characteristic of meridian system in patients with loin lesions. Methods:Electric potentials of well and sea points in the meridians in 17 patients with LWLE diagnosed by both CT or MRI and self view on pain at loin and lower extremities were repeatedly measured by physiograph(PowerLab). Measurements of those electrical potentials were analyzed by factor analysis. Results The electric potentials of WSBTM at the left side were divided into four factors. On the other hand those at the right side wert divided into three factors.

  • PDF