• 제목/요약/키워드: electric impedance

검색결과 586건 처리시간 0.024초

20 kHz 전력설비 접지시스템 분석에 관한 연구 (Study to Analyze the Grounding System in the 20 kHz Power Installation)

  • 정진수;한운기;박찬엄;송영상;임현성
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1308-1312
    • /
    • 2013
  • In this paper, carried out for optimal ground system for ensuring safety for electricity used to power equipment in the 20 kHz frequency. Now the grounding system of the mesh electrode, electrode rods are installed for power plant safety and protection against electric shock. However, the electrical equipment grounding system in the 20 kHz were considering the increasing grounding impedance due to the high frequency and the magnetic shielding. But until now, there has been little research on the grounding system. To solve this problem, In this paper was proposed optimal grounding system due to the experiment using a mesh electrode, rod electrode, aluminum plate electrodes. Measurement results, grounding resistance was depending on the material of the electrode grounding resistance. In addition, the leakage current (induced) appeared to be affected depending on the type of electrode.

고조파 장해의 진상에 관한 연구 (A Study on the Real Features of Harmonic Obstacle)

  • 이해기
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.162-171
    • /
    • 1998
  • This paper presents the harmonics obstacle analysis and countermeasure of electrical consumption a place. Harmonics that can be cosidered as a environmental pollution of the power systems become the cause of the accidents and damages. The responsibility of eliminating the harmonics firstly lies on the generating side. But the original characteristics of the system sush as the harmonic transfer characteristics and the impedance of the system affect each other in the process of the generation and transmission of the harmonic. Therefore it is very difficult to specify clearly the harmonic controlling responsibility, because electric machinery generating harmonics are various in the industrial fields. The output of a inverter has a high harmonic content. There are several ways of minimizing the output harmonic content. One way is to use pulse width modulation techniques within inverter. An alternative method is to combine a number of square-wave inverters. In this research, we measure the harmonic of the countermeasure of electrical consumption a place. The paper present the problem of new harmonic elimination method of PWM inverter fed induction motor system using W-FT series. In the future, the proposed PWM pattern by W-FT series is effective not only to the induction motor but also to the electromagnetic machine such as voltage reglator, UPS.

  • PDF

EMTP-RV를 이용한 대용량 전기설비의 차단기 TRV에 관한 연구 (A Study on the Circuit Breaker Transient Recovery Voltages on Large Commercial Customer using EMTP-RV Program)

  • 조계술;최홍규
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.59-66
    • /
    • 2011
  • In electric power system, the circuit breaker is not operated when the higher voltage then the rated TRV(transient Recovery Voltage) appeared in the circuit breaking, The TRV of a circuit breaker means the characteristics of reignition by the arc between two poles. and is decided by the value of connecting Impedance. In this paper we of carried out many kinds of experiments varying the types of bus, the types of installation, the length of installation between 22.9 [kV] level circuit breaker and MTR in general 154/22.9[kV] system, We also simulated the characteristics of TRV using EMTP-RV program. The suitability of TRV in assessed by Uc, RRRV(Rate of Rise of Recovery Voltage) which are defined by the international guide, IEC62271-100. The values of RRRV gained from the cable-made bus are 590[%] lesser than those from the NSPB-made bus respectively. So the triangled type is more rational in the aspect of TRV.

Image Capturing of Dispersed Phases in DCHXs by Electric Tomography

  • Chun, Won-Gee;Kim, Min-Chan;Lee, Heon-Ju;Kang, Yong-Heack;Kwon, Hyok-Bo
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.69-78
    • /
    • 2001
  • This paper introduces the physical phenomena involved in Direct Contact Heat Exchangers (DCHXs) and also investigates the possibility of applying of EIT(Electrical Impedance Tomography) technique for capturing the images of dispersed phases as they stream through a stagnant body of water. A number of cases are studied where two dimensional cross-sectional static images are given for fictitious and actual masses present in a column of water(saline solution). In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density different(lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the elucidation of complicated flow field where the dispersed phase fluid tends to change its shape and size constantly during its journey through the other phase(water). This paper presents a number of results with different types of dispersed phases that are immiscible with water. The EIT technique has been employed in this context to test its applicability in capturing the dynamic images of dispersed phases. It shows static images of dispersed phases where dynamic images could be obtained by simply extending the algorithms and strategies employed in the present analysis.

  • PDF

Self-reliant wireless health monitoring based on tuned-mass-damper mechanism

  • Makihara, Kanjuro;Hirai, Hidekazu;Yamamoto, Yuta;Fukunaga, Hisao
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1625-1642
    • /
    • 2015
  • We propose an electrically self-reliant structural health monitoring (SHM) system that is able to wirelessly transmit sensing data using electrical power generated by vibration without the need for additional external power sources. The provision of reliable electricity to wireless SHM systems is a highly important issue that has often been ignored, and to expand the applicability of various wireless SHM innovations, it will be necessary to develop comprehensive wireless SHM devices including stable electricity sources. In light of this need, we propose a new, highly efficient vibration-powered generator based on a tuned-mass-damper (TMD) mechanism that is quite suitable for vibration-based SHM. The charging time of the TMD generator is shorter than that of conventional generators based on the impedance matching method, and the proposed TMD generator can harvest 16 times the amount of energy that a conventional generator can. The charging time of an SHM wireless transmitter is quantitatively formulated. We conduct wireless monitoring experiments to validate a wireless SHM system composed of a self-reliant SHM and a vibration-powered TMD generator.

전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구 (A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC))

  • 김용태;신관우;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

ZnO 나노파우더 바리스터의 제작과 전기적 특성 (Fabrication and Electrical Characteristics of ZnO Nano-powder Varistors)

  • 유인성;정종엽;박춘배
    • 한국전기전자재료학회논문지
    • /
    • 제18권12호
    • /
    • pp.1117-1123
    • /
    • 2005
  • In this study, our varistors based on M. Matsuoka's composition were fabricated with ZnO nano-powder whose sizes were 50 nm and 100 nm. Before fabrication of ZnO nano-powder varistors, structure and Phase were analyzed by FE-SEM and XRD with size of ZnO nano-powders to obtain manufacturing information to fabricate the first ZnO varistors using by nano-powders. As a results of these analyses, calcination and sintering temperatures were respectively designed at $600^{\circ}C\;and\;1050^{\circ}C$. ZnO nano-powder varistors were analyzed by SEM and XRD to measure the changes of microstructures and phase after sintered by out process conditions. Also, electrical properties of ZnO nano-powder varistors were obtained by capacitance-voltage, frequency-teal impedance, and current-voltage corves. Our ZnO nano-powder varistors had about 2.5 times of electric field at varistor voltage as compared with normal ZnO varistors fabricated with micro-powder. Also, leakage current and non-liner coefficient respectively had $2.0{\times}10^{-6}A/cm^{-2}$ and 41 for ZnO nano-powder varistors with 50 nm.

PZT 강유전체 박막의 마이크로파 유전특성 (Microwave Dielectric Properties of Ferroelectric PZT Thin Films)

  • 곽민환;문승언;류한철;김영태;이상석;이수재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.719-722
    • /
    • 2003
  • Ferroelectric $Pb(Zr_{1-x}Ti_x)O_3$ (PZT) films were deposited on (001) MgO single crystals using sol-gel method. Structural properties and surface morphologies of PZT films were investigated using an X-ray diffractometer and a scanning electron microscopy, respectively. The dielectric properties of PZT films were investigated with the dc bias field using interdigitated capacitors (IDC) which were fabricated on PZT films using a thick metal layer by photolithography and dry etching process. The small signal dielectric properties of PZT films were calculated by a modified conformal mapping method with low and high frequency data, such as capacitance measured by an impedance gain/phase analyzer at 100 kHz and reflection coefficient (S-parameter) measured by a HP 8510C vector network analyzer at 1 -20 GHz. The IDC on PZT films exhibited about 67% of capacitance change with an electric field of 135 kV/cm at 10 GHz. These PZT thin films can be applied to tunable microwave devices such as phase shifters, tunable resonators and tunable filters.

  • PDF

Wireless Energy Transfer System with Multiple Coils via Coupled Magnetic Resonances

  • Cheon, Sanghoon;Kim, Yong-Hae;Kang, Seung-Youl;Lee, Myung Lae;Zyung, Taehyoung
    • ETRI Journal
    • /
    • 제34권4호
    • /
    • pp.527-535
    • /
    • 2012
  • A general equivalent circuit model is developed for a wireless energy transfer system composed of multiple coils via coupled magnetic resonances. To verify the developed model, four types of wireless energy transfer systems are fabricated, measured, and compared with simulation results. To model a system composed of n-coils, node equations are built in the form of an n-by-n matrix, and the equivalent circuit model is established using an electric design automation tool. Using the model, we can simulate systems with multiple coils, power sources, and loads. Moreover, coupling constants are extracted as a function of the distance between two coils, and we can predict the characteristics of a system having coils at an arbitrary location. We fabricate four types of systems with relay coils, two operating frequencies, two power sources, and the function of characteristic impedance conversion. We measure the characteristics of all systems and compare them with the simulation results. The flexibility of the developed model enables us to design and optimize a complicated system consisting of many coils.

반도체 Ash 공정용 PWM 제어 Plasma 발생방법 (Plasma Generation Method using PWM Control for Ash Process)

  • 이정호;최대규;최상돈;이병국;원충연;김수석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.470-474
    • /
    • 2006
  • This dissertation discuses about a ferrite core plasma source using low operating frequency without sputtering problem by the stored electric field. Compared with the conventional RF power system with 13.56MHz switching frequency, the proposed plasma power system is only separated at 400kHz, so that it makes possible to use of low cost switching elements, PWM control and soft switching. Moreover, it could improve the coupling efficiency for plasma and antenna by using the ferrite core in order to transfer the energy of the load This dissertation tried to analyze new plasma generation method for the plasma generation system by modeling the plasma load and grafting the concept of impedance matching in order to interpret it with the formula This dissertation verified the ferrite core inductive coupling plasma source authorized for 400kHz of low frequency power by applying to the semi-conductor ash process thru the measurement of ash capacity and uniformed plasma distribution on the actual wafer.

  • PDF