• 제목/요약/키워드: electric impedance

검색결과 583건 처리시간 0.032초

Degradation of Epoxy Coating due to Aging Acceleration Effects

  • Nah, Hwan Seon;Lee, Chul Woo;Suh, Yong Pyo
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.99-105
    • /
    • 2006
  • This paper is to investigate feasibility on quantitative aging state of epoxy coating on concrete wall in containment structure under operation of nuclear power plants. For evaluating the physical characteristics of the epoxy coating, adhesion strengths of two kinds of degraded epoxy coating systems on both steel surfaces and concrete surfaces were measured via accelerated aging. Comparatively impedance data taken by ultrasonic test were also taken to relate with adhesion data. After aging, in case of concrete, from half of specimens, aging of epoxy coating was developed. As for steel, on $4^{th}$ inspection day, adhesion force was failed. To improve reliability on quality degradation of epoxy, relationship between adhesion and impedance was analyzed. By tracing to co-respond to these data, it was possible to Fig. out physical state of as-built epoxy coating. The possibility to develop new methodology of time - dependent aging state on epoxy coating was found and discussed.

원통형 배면체를 갖는 PZT 트랜스듀서의 특성평가 (Characteristics Evaluation for a PZT Transducer with a Cylindrical Rear Surface)

  • 김동현;한진호;양정원;김무준;하강렬
    • The Journal of the Acoustical Society of Korea
    • /
    • 제26권1E호
    • /
    • pp.14-20
    • /
    • 2007
  • The characteristics of a PZT transducer with a cylindrical rear surface were investigated theoretically and experimentally. The transducer was assumed as a set of finite rectangular ceramic elements for applying the staircase model to the theoretical analysis and the KLM equivalent circuit model was modified for analyzing its electric impedance and pulse-echo response. All results were compared with those of a conventional plane transducer which has a constant thickness of average value for the cylindrical arc. It was noted that the transducer with a cylindrical rear surface has several subsidiary resonant frequencies which are able to widen bandwidth.

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석 (Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems)

  • 김경철;진성은;이주홍;김유준;최종기;백남웅
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.67-74
    • /
    • 2005
  • 접지 시스템은 전기설비의 기준 전위점을 확보할 뿐만 아니라, 대지에 낮은 저항으로 고장 전류를 흐르게 한다. 고장전류는 넓은 범위의 주파수를 포함하기 때문에 접지의 성능을 평가하기 위해선 주파수에 대한 함수로 접지임피던스에 대한 특성의 분석이 필요하다. 본 논문에서는 상용화된 접지봉(매직봉)의 접지임피던스를 0[Hz]에서 100[kHz] 범위까지 측정하였고, 접지임피던스를 회로 모델과 전달함수 모델로 구하여 측정된 값과 비교 검토하였다.

Compensation on Impedance of the Stratum Corneum

  • Kim, Ki-Won;Choi, Han-Yoon;Sim, Myeong-Heon;Jeong, In-Cheol;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.444-449
    • /
    • 2008
  • This study aims at compensation of the skin moisture level using skin impedance and SR factor. SR factor is related with the current diffusion into the skin layer. To efficiently analyze the current diffusion on the skin model, we used an electromagnetic simulation program called Ansys 10.0 Emag. We confirmed that the measured value decreases as the electric current gets more diffused to the layer below the horny layer. In order to conduct actual experiments based on the simulated result, we manufactured special electrodes with 24 pins by arranging 0.8mm-diameter electrodes every 0.5mm, in a $3{\times}8$ array. By simultaneously achieving both impedance value and SR value of skin with the manufactured electrodes, we compared the skin moisture level using the existing equipment to the skin moisture level applied using the skin impedance as well as the SR factor developed in this study. The correlation coefficient between the skin moisture level achieved from the existing equipment and the reference value was 0.615 (p<0.01), whereas the correlation coefficient between the skin moisture achieved from the regression equation in this study was 0.677 (p<0.01). Accordingly, it was confirmed that applying SR factor additionally improves the moisture level more precisely.

IEC 60364 기반 접지계통 비교 분석 (The Comparison and Analysis about Earth System based on IEC60364)

  • 정진수;한운기;김오환;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-62
    • /
    • 2010
  • 본 논문에서는 IEC 60364에서 제시하고 있는 접지계통(TT접지계통, TN-S 접지계통 및 TN-C)의 누전차단기 동작특성 및 보호도체의 임피던스변화에 따른 Loop Impedance 특성분석을 실시하였다. 분석결과 Loop Impedance의 경우 저항성분과 인턱턴스성분에 영향을 받는 것으로 나타났다. 접지계통별 전류 전압특성은 TN-S 접지계통 및 TN-C 접지계통의 경우 사고전류가 높고 접촉전압이 낮은 특성을 나타낸 반면 TT 접지계통의 경우 사고전류는 낮고 접촉전압이 높게 나타남을 확인하였다.

Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses

  • Nguyen, Tuan-Cuong;Huynh, Thanh-Canh;Yi, Jin-Hak;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • 제24권4호
    • /
    • pp.385-403
    • /
    • 2017
  • In recent years, the wind energy has played an increasingly important role in national energy sector of many countries. To harvest more electric power, the wind turbine (WT) tower structure becomes physically larger, which may cause more risks during long-term operation. Associated with the great development of WT projects, the number of accidents related to large-scaled WT has also been increased. Therefore, a structural health monitoring (SHM) system for WT structures is needed to ensure their safety and serviceability during operational time. The objective of this study is to develop a hybrid damage detection method for WT tower structures by measuring vibration and impedance responses. To achieve the objective, the following approaches are implemented. Firstly, a hybrid damage detection scheme which combines vibration-based and impedance-based methods is proposed as a sequential process in three stages. Secondly, a series of vibration and impedance tests are conducted on a lab-scaled model of the WT structure in which a set of bolt-loosening cases is simulated for the segmental joints. Finally, the feasibility of the proposed hybrid damage detection method is experimentally evaluated via its performance during the damage detection process in the tested model.

DTS 기반 온도 감시 및 온도 조건에서의 배터리 셀 열화 특성 분석 (DTS-based Temperature Monitoring and Analysis of Battery Cell Deterioration Characteristics by Temperature Condition)

  • 권순종;김수연;황진;우상균;김봉석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.143-149
    • /
    • 2022
  • As ESS safety issues increase recently, there is a need to more precisely monitor the temperature of the ESS. In this paper, DTS technology for temperature monitoring of ESS batteries is introduced and the temperature measurement principle is explained. The temperature of the battery module is measured using the DTS system, and the thermal deviation between battery cells inside the battery module is analyzed. In order to analyze how thermal imbalance affects the charging and discharging performance of the battery, an accelerated degradation test was conducted. Cycle life characteristics analysis, battery surface temperature change, and AC impedance characteristics were conducted to analyze how the performance of battery cells differs according to temperature conditions.

Design and characteristic investigations of superconducting wireless power transfer for electric vehicle charging system via resonance coupling method

  • Chung, Y.D.;Yim, Seong Woo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권3호
    • /
    • pp.21-25
    • /
    • 2014
  • As wireless power transfer (WPT) technology using strongly coupled electromagnetic resonators is a recently explored technique to realize the large power delivery and storage without any cable or wire, this technique is required for diffusion of electric vehicles (EVs) since it makes possible a convenient charging system. Typically, since the normal conducting coils are used as a transmitting coil in the CPT system, there is limited to deliver the large power promptly in the contactless EV charging system. From this reason, we proposed the combination CPT technology with HTS transmitting antenna, it is called as, superconducting contactless power transfer for EV (SUWPT4EV) system. As the HTS coil has an enough current density, it can deliver a mass amount of electric energy in spite of a small scale antenna. The SUCPT4EV system has been expected as a noble option to improve the transfer efficiency of large electric power. Such a system consists of two resonator coils; HTS transmitting antenna (Tx) coil and normal conducting receiver (Rx) coil. Especially, the impedance matching for each resonator is a sensitive and plays an important role to improve transfer efficiency as well as delivery distance. In this study, we examined the improvement of transmission efficiency and properties for HTS and copper antennas, respectively, within 45 cm distance. Thus, we obtained improved transfer efficiency with HTS antenna over 15% compared with copper antenna. In addition, we achieved effective impedance matching conditions between HTS antenna and copper receiver at radio frequency (RF) power of 370 kHz.