• 제목/요약/키워드: electric fire

검색결과 582건 처리시간 0.023초

ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

태양광 발전설비가 설치된 건물의 진화 시 주수에 의한 감전의 위험성에 관한 연구 (A Study on the Risk of Electric Shock from the Sprayed Water for Fire Suppression of the PV Installed Building)

  • 김진선;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.47-51
    • /
    • 2014
  • 본 연구에서는 태양광 발전설비가 설치되어 있는 건물에서 화재가 발생할 경우 분사되는 물을 통해 전류가 흐를 가능성 및 감전의 위험성에 대해 고찰하였다. 분사되는 물을 수학적 모델을 통하여 해석 하였고, 물 전도도 측정을 위한 물분사 시스템을 제작하여 유속에 따른 물 저항값을 측정하여 수치적으로 예상한 값과 비교하였다. 실험과 수치계산의 결과로 태양광 발전설비 화재 시 고려되어야 할 사항들을 정의할 수 있게 되었다.

Integrated Safety System based on IoT

  • Shin, Jin Seob
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권10호
    • /
    • pp.159-165
    • /
    • 2019
  • 현재 화재의 58%정도는 전기에 의한 화재이다. 본 연구에서는 전기에 의한 화재의 요인을 분석하여 미연에 화재를 예방이 가능한 시스템에 대하여 연구하였다. 재난재해를 예방하기 위해서는 기본적으로 화재 징후를 알아내기 위한 다양한 전기에 관한 IoT 센서들이 필요하다. 이러한 센서들은 각각 발생하는 많은 상황정보들을 계속적으로 수신하고 메인시스템으로 전송한다. 이렇게 모아진 빅 데이터들은 패턴분석을 통해 재난이 발생할 수 있는 임계치를 벗어나는지 여부를 계속적으로 체크하며 데이터의 비교를 통하여 어느 부분의 문제가 있는지 여부도 체크할 수 있다. 임계치를 벗어나는 상황에는 경보신호를 알려주고 문제 있는 부분에 대한 정보도 전달한다. 이를 통해 과전류, 누설전류 등과 같은 전기적인 문제를 미연에 방지함으로써 화재를 예방할 수 있는 결과를 보여준다.

앱기반 전기화재 예측시스템 개발에 관한 연구 (A Study on Development of App-Based Electric Fire Prediction System)

  • 최영관;김응권
    • 인터넷정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.85-90
    • /
    • 2013
  • 현재 전기화재 예측시스템은 제어용 마이크로프로세서로서 PIC(Peripheral Interface Controller)를 사용하고 있다. PIC는 DSP(Digital Signal Processor)보다 연산속도가 느려 실시간 연산능력이 부족하다. 그래서 아크 발생 시 나타나는 기본 특성파형을 기준 reference로 하여 이 reference와의 비교를 통해 아크로 인한 전기화재를 예측하여 경보한다. 기존의 전기화재 예측시스템은 이러한 경보를 원격의 중앙 서버에서 감시하고 후속 조치를 취할 수 있으나, 그 예측 에러율이 높을 뿐만 아니라, mobile 환경에서 원격제어를 하지 못하는 실정이다. 본 논문에서 시간영역, 주파수영역의 아크검출과 적응알고리즘을 변환영역에서 수행하는 웨이블릿 기반의 적응알고리즘"을 적용하여 새로운 실시간 아크검출 알고리즘이 탑재된 전기화재 예측시스템을 DSP를 이용하여 개발하였다. 또한 아크의 전기적 신호 및 전력품질 대한 원격 모니터링이 실시간으로 가능할 뿐만 아니라, iphone 환경기반의 App 개발을 통해 원격에서 제어가 가능하도록 구축하고 그 유용성을 확인하였다.

화재 모델을 이용한 원자력발전소 안전성 케이블의 열적 특성 분석 (Thermal characteristic analysis for NPP's safety-related cables by fire modeling)

  • 박상진;지문학
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.31-36
    • /
    • 2010
  • 원전 방화지역에서 화재가 발생할 경우 케이블 고장으로 인한 기기의 오동작 및 안전정지 기능에 미치는 영향 평가가 필요하다. 본 논문에서 FDS의 THIEF 모델을 이용하여 환기조건 및 열발생율 변화에 따른 원전 안전정지 케이블의 열적 특성을 분석하였다.

  • PDF

VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석 (Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire)

  • 김두현;김성철;이종호;박종영;박영호;이형준
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치 (Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater)

  • 이문형;김찬오
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구 (Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제10권4호
    • /
    • pp.583-597
    • /
    • 2014
  • 난방기기에 의한 화재는 다양한 난방기기의 종류처럼 그 원인도 다양하고. 매년 계속되는 전통재래시장에서의 난방기기에 의한 화재사고가 빈번히 발생하여 인명 및 재산상의 손실을 초래하고 있다. 일반주택이나 아파트 등 대부분의 주거시설은 난방용 보일러가 보급되어 난방기기로 인한 화재가 그리 많지 않으나 식당, 시장의 점포와 사무실, 체육관, 공장, 작업장 등에서는 여전히 석유난로, 전기난로 등 난방기기를 사용 하고 있어 화재의 위험성에 노출되어 있다. 또한 난방용 기기의 발생건수를 살펴보면 가정용보일러, 목탄난로, 석유난로, 가스난로/스토브, 전기스토브/히터 순으로 발생한 것으로 분석되었으며, 인명피해 별 건수는 가스난로/스토브, 석유난로 /곤로, 전기히터/스토브, 연탄/석탄난로 순으로 분석되었다. 또한 가스 및 석유관련 난방용기기가 발생빈도(frequency)는 낮지만 화재강도(intensity)가 높은 것으로 분석 되었다. 따라서 본 연구의 목적은 다중이용시설인 전통재래시장에서 아직도 많이 사용되고 있고, 실제 화재발생사례가 많은 석유난로와 전기스토브에 의한 발화 위험성 즉 최소발화온도, 탄화 정도와 그에 따른 열유속을 정상상태와 비정상상태 하에서의 가연물의 접촉 및 전도로 인한 화재 발생 가능성을 재연하여 검토해 봄으로서 보다 과학적인 화재조사 및 감식 접근방법을 강구하고자 하였다. 재연실험 결과 실험체 2종(석유난로/전기스토브) 모두 양호한 축열 조건이 만들어지지 않는 한 발화위험성은 극히 적은 것으로 나타났지만 탄화의 상태는 각 부위별로 진행되는 것으로 분석되었다. 결국 화재로의 전이는 축열에 의한 발화이므로 최소한 화재장소의 축열 온도조건이 $500^{\circ}C$ 이상일 때 발화되는 것으로 분석되었다. 특히 전기스토브의 발열체인 석영관인 경우 가장 짧은 시간 내(10sec)에 $600^{\circ}C$ 이상의 온도로 급 가열 되어 이때의 열유속은 6.26kW/m2으로 나타나 이는 보온된 PVC케이블이 손상과 함께 인체에는 2도 화상을 입히는 결과를 나타내는 것으로 분석 되었다. 아울러 온도 조건 이외에 거리변화에 따른 열량의 감소분을 나타내는 형태계수(Geometric View Factor)와 화재하중(Fire Load)에 따른 온도 변화도 고려되어야 할 중요한 변수임 알았다. 따라서 이에 관한 세심한 화재조사 및 감식의 매뉴얼이 있어야 할 것으로 사료되며 이러한 실험에 의한 과학적이고 합리적인 노력들이 향후 화재조사 및 감식에 대한 매뉴얼 작성과 이론적 토대를 세우는데 기여하기를 기대한다.