• 제목/요약/키워드: electric discharge

검색결과 1,279건 처리시간 0.028초

유체법을 이용한 코로나 방전의 1차원 수치해석 (1-Dimensional Simulation of the Corona Discharge using Fluid Method)

  • 이용신;심재학;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

직류 플라즈마 디스플레이를 위한 미소방전특성연구 (The study on micro discharge characteristics for DC Plasma Display)

  • 조정수;박정후;김규섭;곽병구;하홍주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1413-1416
    • /
    • 1995
  • Plasma Display(PDP) was successfully demonstrated on 30-60inch display panel. Research for mass production is also been accelerating. The basic study of PDP are mainly focused on understanding of micro discharge in each cell In this paper, DC PDP with Ag electrode is made and the discharge charcateristics in micro gap is studied with the variation of the distance of electrode gap and the pressure in discharge cell.

  • PDF

유전체 비드를 이용한 수중 방전의 전계 분포 특성 평가 (The simulation on a electric field distribution of dielectric beads with a shape of ball in water)

  • 이동훈;박홍재;박재윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.15-18
    • /
    • 2003
  • In this paper, We explained the best shape design of electrode for discharge on the water. Electrode with rounding was reduced maximum electric field of over 40% to electrode without rounding for discharge on the water and the best shape of electrode for discharge on the water designed when shape of electrode had a curve radius of over $60^{\circ}$ at electrode's face to electrode's face with minimum distance and a curve radius of under $120^{\circ}$ at electrode's side face to electrode's front face. And When dielectric beads are used between electrodes, the life of electrodes is improved by lower stress of electric field on surface of electrodes.

  • PDF

25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교 (Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear)

  • 구선근;한기선;곽주식;주형준;정문규
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends

고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지 (The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp)

  • 한태환;우천희
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

부분방전 전자파 측정용 광대역 주파수 분석 시스템 개발 (The Development of wide frequency analyzing system by partial electric discharge electromagnetic-wave Receiver)

  • 박두용;신영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.547-549
    • /
    • 2004
  • This system is monitors the degree of aging happened at the electric machine. It detects electromagnetic wave generated from the insulator when the voltage is applied to the machine. By analyzing the internal and external factors make the electric, mechanic, or thermal characteristics of the electric machinery deteriorate the electric insulation and eventually cause the partial electric discharge. The continuous partial electric charge accelerates the insulation aging and the insulation breakdown happens at last. This system consists of the relays connected with 10 sensors (40 total) detecting the partial electric discharge ans the temperature, the server, ans the program analyzing and storing the data.

  • PDF

와이어 방전가공에서 전류파형이 양극침식에 미치는 영향 (Influence of Current Waveform on Anode Erosion in Wire Electric Discharge Machining)

  • 조성산;오진혁
    • 한국정밀공학회지
    • /
    • 제18권7호
    • /
    • pp.127-133
    • /
    • 2001
  • The effects of triangular and rectangular discharge current waveforms on anode erosion in wire electric discharge machining is investigated based on heat transfer analysis of half-space subject to time and space-dependent heat flux. The thermal load on the anode is simulated by a hear flux that is calculated from time-dependent discharge channel radius and energy. Evolution of the melting front during discharge, the molten volume at the experimental result for qualitative verification of the analysis. It is demonstrated that the triangular current waveform is more efficient in eroding the anode than the rectangular one.

  • PDF

와이어컷 방전에 의한 합금공구강과 초경합금의 가공특성 (A Study on the Characteristics of Wire-Cut Electric Discharge Machining of Alloyed Tool Steel and Tungsten Carbide)

  • 이재명;허성중;김원일
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.123-133
    • /
    • 1996
  • From the experimental study of wire-cut Electric Discharge Machining of alloyed tool steel and tungsten carbide, the characteristics such as cutting speed, surface roughness has been observed and evaluated for various conditions. Cutting speed is improved as peak discharge current and wire tension become increased, and gap voltage and spark cycle decreased. Surface roughness can be better when peak discharge current and gap voltage become smaller, or spark cycle and wire tension become larger. Secondary cut is recommended to obtain high precision and good quality.

  • PDF

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.