• Title/Summary/Keyword: electric cap

Search Result 61, Processing Time 0.028 seconds

Effects of sheds and cemented joints on seismic modelling of cylindrical porcelain electrical equipment in substations

  • Li, Sheng;Tsang, Hing-Ho;Cheng, Yongfeng;Lu, Zhicheng
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.55-65
    • /
    • 2017
  • Earthquake resilience of substations is essential for reliable and sustainable service of electrical grids. The majority of substation equipment consists of cylindrical porcelain components, which are vulnerable to earthquake shakings due to the brittleness of porcelain material. Failure of porcelain equipment has been repeatedly observed in recent earthquakes. Hence, proper seismic modelling of porcelain equipment is important for various limit state checks in both product manufacturing stage and detailed substation design stage. Sheds on porcelain core and cemented joint between porcelain component and metal cap have significant effects on the dynamic properties of the equipment, however, such effects have not been adequately parameterized in existing design guidelines. This paper addresses this critical issue by developing a method for taking these two effects into account in seismic modelling based on numerical and analytical approaches. Equations for estimating the effects of sheds and cemented joint on flexural stiffness are derived, respectively, by regression analyses based on the results of 12 pieces of full-scale equipment in 500kV class or higher. The proposed modelling technique has further been validated by shaking table tests.

Finite Element Analysis for the Optimal Shape of the High Voltage Insulator for Power Transmission Lines (송전선로용 고전압 절연체의 최적 형상에 대한 유한요소 해석)

  • Kim, Taeyong;Sanyal, Simpy;Rabelo, Matheus;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.66-71
    • /
    • 2022
  • The insulator used for the transmission line is a device that is bonded with a cap, pin, ceramic, and cement to withstand insulation capacity and mechanical load. The insulator design can help to reduce the dispersion of the electric field; thus, the optimization of today's design, especially as demanded power grows, is critical. The designs of four manufacturers were used to perform a comparative analysis. Under dry circumstances of the new product, an electric field distribution study was done with no pollutants attached. Manufacturer D's design has the best voltage uniformity of 24.33% and the arc length of 500 mm or more. Manufacturer C's design has an equalizing voltage of more than 2% higher than that of other manufacturers. The importance of the design of the insulator and the number of connections according to the installation conditions is very efficient for transmission lines that will increase in the future.

Hybrid Integration of P-Wave Velocity and Resistivity for High-Quality Investigation of In Situ Shear-Wave Velocities at Urban Areas (도심지 지반 전단파속도 탐사를 위한 P-파 속도와 전기비저항의 이종 결합)

  • Joh, Sung-Ho;Kim, Bong-Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.45-51
    • /
    • 2010
  • In urban area, design and construction of civil engineering structures such as subway tunnel, underground space and deep excavation is impeded by unreliable site investigation. Variety of embedded objects, electric noises and traffic vibrations degrades the quality of site investigation, whatever the site-investigation technique would be. In this research, a preliminary research was performed to develop a dedicated site investigation technique for urban geotechnical sites, which can overcome the limitations of urban sites. HiRAS (Hybrid Integration of Surface Waves and Resistivity) technique which is the first outcome of the preliminary research was proposed in this paper. The technique combines surface wave as well as electrical resistivity. CapSASW method for surface-wave technique and PDC-R technique for electrical resistivity survey were incorporated to develop HiRAS technique. CapSASW method is a good method for evaluating material stiffness and PDC-R technique is a reliable method for determination of underground stratification even in a site with electrical noise. For the inversion analysis of HiRAS techniuqe, a site-specific relationship between stress-wave velocity and resistivity was employed. As for outgrowth of this research, the 2-D distribution of Poisson's ratio could be also determined.

Considerations on the Safety of Electric Caps Based on Measured Electrical Resistivity of Rock Samples (암석의 전기비저항 측정을 통한 전기뇌관의 사용 안전성 검토)

  • Choi, Byung-Hee;Ryu, Chang-Ha;Shin, Seung-Wook;Kim, Soo-Lo
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.19-27
    • /
    • 2016
  • Much care should be taken when electric caps are used in blast site than when non-electric initiation systems are used. This is because electric caps can cause premature firing or misfires if stray currents of high magnitude flow into the blasting circuit. If the rock has higher electrical conductivity or lower electrical resistivity, such risks will be increased because the rock will provide more passages for the stray currents to flow into the blasting circuit. In this study, several rock samples obtained at a blast site were tested for electrical resistivity to decide whether electric caps could be used or not in the site. The measured electrical resistivity was $39{\sim}47{\Omega}{\cdot}m$ for the rock samples that had a higher content of metal sulfides. Contrary, the resistivity was $15000{\sim}21000{\Omega}{\cdot}m$ for ordinary rocks. Especially, in the case of the rock of electric resistivity of $39{\Omega}{\cdot}m$, only 2-V electric potential enables a stray current to flow through the rock of 1-m length, which can cause the premature firing of a detonator whose initiation current is 0.4 A. This result shows that electric initiation system should not be used in the site because rocks containing much amount of metal sulfides are widely distributed there.

Numerical analysis of HgCdTe heterojunction photodiodes (HgCdTe 이종접합 광다이오드의 수치 해석)

  • 조남홍;곽규달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.45-55
    • /
    • 1997
  • Electircal characteristics of HgCdTe photodiodes with a heterostructure to achieve high performance are analyzed numerically. A two-dimensional device simulator which can handle a HgCdTe heterostructure, was developed for this work. The effects of band nonparabolicity, carrier degeneracy, and band-offset of heterointerace are included in a carrier transport model. A unified generation-recombination model includes simultaneously phonon-assisted tunneling and pure tunneling of carriers via traps is newly employed for describing the electric field and temperature dependency of dark current effectively. Furthermore, to accurately predict the effect mole fraction variations on genration rates, ray-trace algorithm is incorporated in the our simulator. Under the various circumstances such as dark, illumination, and surface states, electrical properties of planar heterostructure photodiode are presented and those of homojunction are compared. These results serve as a explanation of cap layer's role on performance.

  • PDF

Measurement and Analysis of Electromagnetic field for DC electric railway train (직류철도차량에 대한 자계측정 및 분석)

  • Jang, Dong-Uk;Kim, Min-Cheol;Lee, Chang-Mu;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

Study on the solution for the overflow of molten solder during the soldering of fuse cap through CFD analysis (전산유체해석을 통한 퓨즈캡 솔더링 시의 용융솔더 넘침 문제 해결방안 연구)

  • Jeong, Nam-Gyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.31-36
    • /
    • 2018
  • Fuses are used to protect electric circuits or devices from excess current. Glass-tube fuses are typically used, but problems have arisen due to the mandated switch from conventional solder to lead-free solder. This study used CFD to simulate the phenomenon of molten solder being poured out of a fuse during the soldering process for a fuse cap and fuse element. In addition, a method is proposed to prevent solder from overflowing, and its effectiveness was verified based on the analysis results. The results show that a sufficient increase of the temperature inside the glass tube before soldering and gravity can help to prevent the solder from overflowing.

The Effect of Baltic Dry Index on the Korean Stock Price Volatility (발틱운임지수가 한국 주가 변동성에 미치는 영향)

  • Choi, Ki-Hong;Kim, Dong-Yoon
    • Journal of Korea Port Economic Association
    • /
    • v.35 no.2
    • /
    • pp.61-76
    • /
    • 2019
  • The purpose of this study is to use the EGARCH model and Granger causality test to analyze how the change in the BDI affects the Korean stock price volatility. The main analysis results are summarized as follows. First, according to the results of the mean equation, the change in the BDI is significant in large-cap stocks, as well as in the manufacturing, service, and chemistry indexes, but not in others. This implies that the Korean stock market does not respond appropriately to the maritime market situation; further, the increase in demand for raw materials has not led to a real economic recovery. Second, in the result of the variance equation, the coefficient on the change in the BDI is negative(-), and the change in the BDI is significant for all size indexes. Particularly, the change in the BDI has a greater impact on the volatility of small-cap stocks than that of large-cap stocks. The results of the analysis of the sector indexes were statistically significant for the service, financial, construction, and electric and electronics industries, but not for the manufacturing and chemical industries. In particular, the changes in the BDI have the greatest impact on the construction industry. Third, according to the Granger causality test results, the change in the BDI leads the financial industry and construction industry. There is, however, no relationship between the BDI and the other indexes. This shows that change in the shipping freight index can be used to predict the volatility in the Korean stock market. This can help investors and policymakers make better decisions.

Pseudo-DC Resistivity Survey for Site Investigation at Urban Areas with Ambient Electrical Noises (전기잡음 간섭이 있는 도심지 지역 탐사를 위한 유사직류 전기비저항 기법)

  • Joh, Sung-Ho;Kim, Bong-Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.37-44
    • /
    • 2010
  • Recently, urban retrofit and extension, development of new buildings and facilities, and construction of underground structures like subway tunnels in urban areas give rise to significance of site investigation at urban areas. However, ambient electric noises, traffic vibrations, embedded objects work as obstacles to high-quality and accuracy in site investigation at urban areas. In this paper, a new technique called the pseudo-DC resistivity survey (in brief, PDC-R) was proposed to minimize the adverse effect of ambient electrical noises in resistivity survey. PDC-R technique utilizes an AC current with frequency range of 0.1 to 1.0 Hz rather than DC current, which is used for conventional resistivity survey. The motivation of using low-frequency AC current is to avoid 60-Hz components or its multiples in the resistivity survey which ambient noises are mostly composed of. The implementation of PDC-R technique also included the parametric study on skin effect, frequency effect and current-level effect, which led to the determination of optimal values of frequency and current level for PDC-R survey. The reliability and feasibility of PDC-R technique was verified through field tests, accompanied by the comparison with DC resistivity survey and CapSASW tests.

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF