• Title/Summary/Keyword: electric cap

Search Result 61, Processing Time 0.03 seconds

Design of Cap Inspection Algorithm of Fuse Cap (퓨즈 캡의 검사를 위한 알고리즘 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.28-33
    • /
    • 2010
  • In this paper, we proposed to the inspection algorithm for cap, Electric fuse is an over current and circuit protection device which is occurred in electric & electronic appliance. Also the fuse are protection the second hazard at arc etc. Fuse are interest regarding a safety increased. Consequently, the fuse came to be very important. Cap inspection algorithm is designed for the cap of fuse. CCD camera is monitering the solder of cap distribution map. The conditioning of fuse cap; suming all searching data with non solder area. the area is bigger reference data then the cap is bad cap.

Estimation of Polar Cap Potential and the Role of PC Index

  • Moon, Ga-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.259-267
    • /
    • 2012
  • Polar cap potential has long been considered as an indicator for the amount of energy flowing in the magnetosphere-ionosphere system. Thus, the estimation of polar cap potential is important to understand the physical process of the magnetosphere. To estimate the polar cap potential in the Northern Hemisphere, merging electric field by Kan & Lee (1979) is adopted. Relationships between the PC index and calculated merging electric field ($E^*$) are examined during full-time and storm-time periods separately. For this purpose Dst, AL, and PC indices and solar wind data are utilized during the period from 1996-2003. From this linear relationship, polar cap potential (${\Phi}^*$) is estimated using the formula by Doyle & Burke (1983). The values are represented as $58.1{\pm}26.9$ kV for the full-time period and $123.7{\pm}84.1$ kV for a storm-time period separately. Considering that the average value of polar cap potential of Doyle & Burke (1983) is about 47 kV during moderately quiet intervals with the S3-2 measurements, these results are similar to such. The monthly averaged variation of Dst, AL, and PC indices are then compared. The Dst and AL indices show distinct characteristics with peaks during equinoctial season whereas the average PC index according to the month shows higher values in autumn than in spring. The monthly variations of the linear correlation coefficients between solar wind parameters and geomagnetic indices are also examined. The PC-AL linear correlation coefficient is highest, being 0.82 with peaks during the equinoctial season. As with the AL index, the PC index may also prove useful for predicting the intensity of an auroral substorm. Generally, the linear correlation coefficients are shown low in summer due to conductance differences and other factors. To assess the role of the PC index during the recovery phase of a storm, the relation between the cumulative PC index and the duration is examined. Although the correlation coefficient lowers with the storm size, it is clear that the average correlation coefficient is high. There is a tendency that duration of the recovery phase is longer as the PC index increases.

Vibration Reduction of Electric Hand Grinder (전동 핸드그라인더의 진동 저감#)

  • 조성진;최연선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.1035-1040
    • /
    • 2004
  • The vibration of an electric hand grinder originates from the motor, gear, bearing, and fan. Its excessive vibration can be harmful to workers. To reduce the vibration of an electric hand grinder. frequency analysis for the vibration signals of a running electric hand grinder and modal test for the each part were done. The results show that the vibration is due to the resonance of the case. To remove the resonance, the case structure was modified and the bearing cap was replaced on a basis of the results of the rotor dynamic analysis using SAMCEF. As a result, the vibration of the electric hand grinder was reduced greatly.

Development of Optimum Shape Forming Technology of Angle Ring and Cap for 154 kV Transformer Insulation (154 kV급 변압기 절연물 앵글링과 캡의 최적성형 기술 개발)

  • Suh, Wang-Byuck;Kim, Jong-Won;Ryu, Jung-Soo;Bae, Dong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.11
    • /
    • pp.880-885
    • /
    • 2010
  • The Angle Ring and Cap which is called pressboard are settled at the primary and secondary coil winding of 154 kV transformer that can reduce effectively distance of insulation. As it has not manufactured pressboard of Angle Ring and Cap for high voltage grade, insulation components industry especially high voltage transformer has not participate in a competition with worldwide yet. That's why is difficult to make an specialized shape of insulation components of high voltage grade. Therefore it has finally completed to make an deformation manufacturing utility using an bellowed special analysis tools. This study that uses various analysis program determining optimum shape about insulation of Angle Ring and Cap which is related life of high voltage transformer. In addition to develop forming equipment with an specialized five steps pressing. That is also based on the mechanical strength evaluation and test, it is investigated optimized processing components.

Vibration Reduction of Electric-powered Hand Grinder (전동 핸드그라인더의 진동 저감)

  • 조성진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.831-836
    • /
    • 2004
  • Vibration of electric-powered hand grinder comes from the parts of motor, gear, bearing, and fan. Excessive vibration can be harmful to workers. To reduce vibration of a hand grinder we analyzed the frequency components from the routing electric-powered grinder and did modal test to find the natural frequencies of the each part. It shows that the vibration is due to the resonance of the case. To remove the resonance, the case structure is modified and the bearing cap is replaced on a basis of the results from the rotor dynamic analysis using SAMCEF. As a result the vibration of the hand grinder is reduced greatly.

  • PDF

Analysis of Electricity Price Cap Transacted via Interstate Electric Power System in Northeast Asia (동북아 전력계통 연계를 통한 융통전력 도입 시 가격상한 수준에 대한 분석)

  • Chung, Koo-Hyung;Kim, Hong-Geun;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.772-774
    • /
    • 2005
  • Interstate electric power system, as an alternative for energy cooperation under regional economic bloc, has been hotly debated before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., electric power system interconnection in this region may bring considerable economic benefits. Moreover, since Korean electric power system has a great difficulty in a geographical condition to interrupt electricity transaction with other countries, it has been expanded as an independent system to supply all demand domestically. As a result, Korean electric power system makes considerable payment for maintaining system security and reliability and expands costly facilities to supply a temporary summer peak demand. Under this inefficiency, if there are electricity transactions with Russia via the North Korea route then economic electric power system operation may be achieved using seasonal and hourly differences in electricity price and/or load pattern among these countries. In this paper, we estimate price cap of transacted electricity via interstate electric power system in northeast asia. For this study, we perform quantitative economic analysis on various system interconnection scenarios.

  • PDF

Development of Optimum Shape Forming Technology of Angle Ring and Cap for 154kV transformer Insulation (154kV급 변압기절연물 앵글링과 캡의 최적성형 기술 개발)

  • Suh, Wang-Byuck;Kim, Jong-Won;Jang, Sung-Ju;Ryu, Jung-Soo;Bae, Dong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.30-30
    • /
    • 2010
  • The Angle Ring and Cap which is called pressboard are settled at primary and secondary coil winding of 154 kV transformer that can reduce effectively distance of insulation. As it has not manufactured pressboard of Angle Ring and Cap for high voltage grade, insulation components industry especially high voltage transformer has not participate in a competition with worldwide yet. That's why is difficult to make an specialized shape of insulation components of high voltage grade. At first, it is very important to make an utility of deformation manufacturing for high voltage transformer insulation components by itself. Therefore it has finally completed to make an deformation manufacturing utility using an special analysis tools. In this paper, developed insulation components was investigates in tensile strength is introduced.

  • PDF