• Title/Summary/Keyword: elastic body

검색결과 526건 처리시간 0.024초

정사각틀 초음파 모터의 변위 특성 (Displacement Characteristics of the Square-frame Ultrasonic Motor)

  • 김종욱;박충효;임정훈;정성수;김명호;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제24권9호
    • /
    • pp.733-738
    • /
    • 2011
  • A novel design of a simple square-frame USM (ultrasonic motor) was proposed. The stator of the motor consists of a square-frame shape elastic body and four rectangular plate ceramics. The four ceramics were attached to inner surfaces of the square frame elastic body. The same phase voltages were applied to the ceramics on horizontal surfaces, and 90 degree phase difference voltage were applied to the ceramics on vertical surfaces. To find a model that generates elliptical motion at outside of the stator, the finite element analysis program ATILA was used. The analyzed results were compared to the experimental results. As result, the model EL10EH3ET0.5CL4 which generates the maximum elliptical displacement was chosen by analyzing the resonance mode according to changes in frequency.

초음파 모터용 디스크형 고정자의 전기기계적 특성 (The Electro-Mechanical Properties of Disk-Type Stator for Ultrasonic Motor)

  • 이종섭;김복원;이세형;신세일;남기동;오흥기;장여진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.339-340
    • /
    • 2006
  • In this paper, disk-type ultrasonic motor using radial and bending vibration modes is newly designed and fabricated to measure its characteristics. As the diameter of elastic body increases, the resonant frequency decreases and its resonant frequency is about 92kHz when the physical dimensions of piezoelectric ceramic and elastic body are 28mm of diameter and 2mm of thickness, and 32mm of diameter and 2mm of thickness, respectively. When the applied voltage is 20Vpp. its speed and torque are 200rpm and 1N, respectively.

  • PDF

Thin-Type 초음파모터의 설계 및 제작 (Design and Fabrication of a Thin-Type Ultrasonic Motor)

  • 김종욱;박충효;정현호;정성수;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.525-529
    • /
    • 2010
  • In this paper, the characteristics of a thin-type ultrasonic motor generating elliptical displacements analyzed by FEM are presented, and then fabrication of the motor is then described. The structure of the motor consists of sixteen ceramic pieces attached to the upper and bottom surfaces of an elastic body. The principle of the motor is to apply alternating voltages which have a 90 phase difference to the attached ceramics, and then elliptical displacements are generated at four edges of the elastic body. Then the rotor is moved by the elliptical displacements. In the case of a ceramic thickness of 1.5, the highest speed was obtained at 79 kHz. In the case of a ceramic thickness of 2 mm, the highest speed was obtained at 77.5 kHz. Consequently, the speed and torque of the ultrasonic motor (USM) increased linearly with increasing applied voltage.

Numerical simulation on strata behaviours of TCCWF influenced by coal-rock combined body

  • Cheng, Zhanbo;Pan, Weidong;Li, Xinyuan;Sun, Wenbin
    • Geomechanics and Engineering
    • /
    • 제19권3호
    • /
    • pp.269-282
    • /
    • 2019
  • Due to top-coal and immediate roof as cushion layer connecting with support and overlying strata, it can make significant influence on strata behaviors in fully mechanical top-coal caving working face (TCCWF). Taking Qingdong 828 working face as engineering background, $FLAC^{3D}$ and $UDEC^{2D}$ were adopted to explore the influence of top-coal thickness (TCT), immediate roof thickness (IRT), top-coal elastic modulus (TCEM) and immediate roof elastic modulus (IREM) on the vertical stress and vertical subsidence of roof, caving distance, and support resistance. The results show that the maximum roof subsidence increases with the increase of TCT and IRT as well as the decrease of TCEM and IREM, which is totally opposite to vertical stress in roof-control distance. Moreover, although the increase of TCEM and IREM leading to the increase of peak value of abutment pressure, the position and distribution range have no significant change. Under the condition of initial weighting occurrence, support resistance has negative and positive relationship with physical parameters (e.g., TCT and IRT) and mechanical properties (e.g., TCEM and IREM), respectively.

폭약을 이용한 밀폐압력용기 해체에 관한 기초적 실험연구 (An Experimental Study on Confined Steel Structure Blasting Demolition)

  • 이하영;김용균;양국정;허원호;강대우
    • 화약ㆍ발파
    • /
    • 제30권2호
    • /
    • pp.43-51
    • /
    • 2012
  • 현재까지 발파해체는 건축물과 토목구조물들을 대상으로 하고 있으나 본 연구에서는 밀폐철재구조물(압력용기) 내부에 물을 채우고 폭약의 힘이 작용하는 해체에 관한 기초연구를 하였다. 일정양의 폭약을 밀폐압력용 기내에 넣고 완전 탄성체로 가정할 수 있는 물($H_2O$)을 압력전달 매개체로 하여 밀폐압력용기의 파괴양상을 관찰하였다. 이때 폭발압력은 Abel의 상태방정식을 이용하여 정량화 하였으며, 그 결과 압력전달 매개체(물)가 있을 경우 밀폐압력용기의 인장강도보다 작은 힘으로 파괴가 발생하였으며, 그렇지 않은 경우에는 약 7.1~8.5배의 폭발압력이 필요하였다. 또한, 압력전달 매개체가 없을 경우(공기만 존재) 폭발압력은 일정값에 도달하기 전까지 파괴에 영향을 미치지 못하고 완전 소산 또는 비산하는 현상을 나타내었다. 실험에 이용한 강철(steel)로 이루어진 밀폐압력용기는 파괴되는 양상에 있어서 대부분 탄성-소성파괴의 형태를 보였으며 최초 항복이 일어나는 지점은 용접부위의 경계부분으로 열소성 변형을 받았다고 판단되는 부분이었다.

고탄성 런닝화가 생체역학적 요소에 미치는 영향 (Effect of High Elastic Running Shoes on Biomechanical Factors)

  • Lee, Jungho
    • 한국운동역학회지
    • /
    • 제30권4호
    • /
    • pp.285-291
    • /
    • 2020
  • Objective: Shoes midsole are crucial for reducing impact forces on the lower extremity when someone is running. Previous studies report that the cushioning of running shoes make it possible to use less muscular energies. However, the well cushioned shoes result in energy loss as the shoe midsole is compressed. Cushioning reduces the load on the body, it also results in the use of more muscle energy to create propulsion force. The purpose of this study was to investigate the effect of the difference of shoe hardness & resilience on the running. Method: Shoes midsole are crucial for reducing impact forces on the lower extremity when someone is running. Previous studies report that the cushioning of running shoes make it possible to use less muscular energies. However, the well cushioned shoes result in energy loss as the shoe midsole is compressed. Cushioning reduces the load on the body, it also results in the use of more muscle energy to create propulsion force. The purpose of this study was to investigate the effect of the difference of shoe hardness & resilience on the running. Results: In vastus lateralis muscle Activation, Type 55 were significantly higher for Type 50 and X (p=0.019, p=0.045). In Gluteus Maximus muscle activation, Type 55 was significantly lower for type 50 (p=0.005). In loading late, Type 55 and X were significantly higher for type 45 (p=0.008, p=0.006). Conclusion: The components of a shoe are very complex, and there can be many differences in manufacturing as well. Although some differences can be found in the biomechanical variables of the high elastic midsole, it is difficult to interpret the performance enhancement and injury prevention.

키네시오 테이핑이 태권도 선수의 하지 근활성도에 미치는 영향 (The Effects of Kinesio-Taping of Lower Limbs on Muscle Activity for Taekwondo Athletes)

  • 양대중;최은영;박동수;박승규
    • 대한임상전기생리학회지
    • /
    • 제9권1호
    • /
    • pp.35-39
    • /
    • 2011
  • Purpose : The purpose of this study was to determine changes in muscle activity due to elastic taping at the rectus femoris, biceps femoris and tibialis anterior muscles using surface electromyography analysis. Methods : In this study 10 healthy university students in the Department of Taekwondo Studies were screened and individuals with a history of previous injury or surgery to their nerve, muscle, and skeletal systems, such as paresthesia and motor disorder, were excluded. Subjects were taped over the rectus femoris, biceps femoris, and tibialis anterior and their muscle activities were analyzed using the surface electromyography method during maximal voluntary isometric contraction. Results : The results of this study were as follows: muscle activities indicated a significant increase after elastic taping than before at the rectus femoris, biceps femoris, and tibialis anterior muscle. These results lead us to the conclusion that muscle activity were influenced by elastic taping at the rectus femoris, biceps femoris, and tibialis anterior muscles. Conclusion : The results of this study show that muscle activity can be improved by elastic taping at the lower limbs. These results suggest that elastic taping of muscles in the lower extremities has the capability to increase muscle activity in the body.

형상학적 변수에 따른 다공성 구조의 가변탄성계수를 기반으로 한 추간체유합보형재의 임상적 안전성 평가 (Clinical Safety Evaluation of Interbody Fusion Cage Based on Tunable Elastic Modulus of the Cellular Structure According to the Geometrical Variables)

  • 김성진;이용경;최재혁;홍영기;김정성
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.158-164
    • /
    • 2019
  • The interbody fusion cage used to replace the degenerative intervertebral disc is largely composed of titanium-based biomaterials and biopolymer materials such as PEEK. Titanium is characterized by osseointergration and biocompatibility, but it is posed that the phenomenon such as subsidence can occur due to high elastic modulus versus bone. On the other hand, PEEK can control the elastic modulus in a similar to bone, but there is a problem that the osseointegration is limited. The purpose of this study was to implement titanium material's stiffness similar to that of bone by applying cellular structure, which is able to change the stiffness. For this purpose, the cellular structure A (BD, Body Diagonal Shape) and structure B (QP, Quadral Pod Shape) with porosity of 50%, 60%, 70% were proposed and the reinforcement structure was suggested for efficient strength reinforcement and the stiffness of each model was evaluated. As a result, the stiffness was reduced by 69~93% compared with Ti6Al4V ELI material, and the stiffness most similar to cortical bone is calculated with the deviation of about 12% in the BD model with 60% porosity. In this study, the interbody fusion cage made of Ti6Al4V ELI material with stiffness similar to cortical bone was implementing by applying cellular structure. Through this, it is considered that the limitation of the metal biomaterial by the high elastic modulus may be alleviated.

Support working resistance determined on top-coal caving face based on coal-rock combined body

  • Cheng, Zhanbo;Yang, Shengli;Li, Lianghui;Zhang, Lingfei
    • Geomechanics and Engineering
    • /
    • 제19권3호
    • /
    • pp.255-268
    • /
    • 2019
  • Taking top-coal caving mining face (TCCMF) as research object, this paper considers the combination of top-coal and immediate roof as cushion layer to build the solution model of support resistance based on the theory of elastic foundation beam. Meanwhile, the physical and mechanical properties of coal-rock combination influencing on strata behaviors is explored. The results illustrate that the subsidence of main roof in coal wall increases and the first weighting interval decreases with the increase of top-coal and immediate roof thicknesses as well as the decrease of top-coal and immediate roof elastic modulus. Moreover, the overlying strata reflecting on support has negative and positive relationship with top-coal thickness and immediate roof thickness, respectively. However, elastic modulus has limit influence on the dead weight of top-coal and immediate roof. As a result, it has similar roles on the increase of total support resistance and overlying strata reflecting on support in the limit range of roof control distance. In view of sensitive analysis causing the change of total support resistance, it can be regards as the rank of three components as immediate roof weight > overlying strata reflecting on support > top coal weight. Finally, combined with the monitoring data of support resistance in Qingdong 828, the validity of support resistance determined based on elastic foundation beam is demonstrated, and this method can be recommended to adopt for support type selecting in TCCMF.

탄력밴드를 이용한 등척성 엉덩관절 벌림 교각운동이 전방머리자세 환자의 족저압에 미치는 영향 (The Effect Of Isometric Hip Abduction Bridge Exercise Using Elastic Band on Foot Pressure in Patients with Forward Head Posture)

  • 유재호;이상빈
    • 대한정형도수물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.41-49
    • /
    • 2022
  • Background: In patients with forward head posture (FHP), the head is positioned forward, causing increased tension in the muscles and structures of the head, neck, and shoulders. This can result in joint dysfunction that may lead to abnormal afferent information. The purpose of this study was to investigate the effect on foot pressure through the isometric hip abduction (IHA) bridge exercise using elastic bands in patients with FHP. Methods: Twenty patients with FHP were randomly assigned to a study group that applied joint mobilization, soft tissue mobilization, a deep neck flexor strengthening exercise, and the IHA bridge exercise using an elastic band. A control group was also constituted, and members were given joint mobilization, soft tissue mobilization therapies, and the deep neck flexor strengthening exercise. Ten patients were assigned to each group. The static foot pressure and dynamic foot pressure of each patient were measured before and after the intervention, and the interventions for each group were applied twice a week for 4 weeks. Results: Both the study group and the control group showed significant differences in static and dynamic foot pressure before and after the interventions (p<.05). There were no significant differences in foot pressure between the study and control groups. Conclusion: : The results of this study revealed that there were no significant differences between the group doing the IHA bridge exercise using the elastic band and the control group. However, the intervention methods applied to both the groups were effective in improving the body center control of FHP patients.