• 제목/요약/키워드: effluent quality

검색결과 615건 처리시간 0.026초

하수처리수와 하천수를 대상으로 한 생태적 수질정화 비오톱 시스템의 오염물질 제거에 대한 수질정화 평가 (Evaluation of Pollutants Removal for Treated Wastewater Effluent and River Water by Meandering Constructed Wetland System)

  • 이상호
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.131-139
    • /
    • 2012
  • Field experiment was performed from June 2010 to July 2011 to evaluate pollutants removal efficiency in the constructed wetland system for the treated wastewater and the river water. The wetland systems were constructed near Gyungan river. Two different systems with meandering shape were compared for seasonal base and operational period base. Several kinds of aquaculture are planted through the corridor of wetland system. Average removal rate of BOD, T-N and T-P for A system were 15.8%, 14.8% and 26.5%, respectively. Average removal rate of BOD, T-N and T-P for C system were 23.5%, 27.8% and 10.6%, respectively. The effluent from two wetland systems often exceeded effluent water quality standards for wastewater influent, however effluent water quality standards for river water. However, the wetland system can be useful to treat polluted river water and effluent from wastewater plant. Removal rate of pollutants in seasonal variation was the highest in summer for BOD and T-N, however the removal rates of T-P were higher in spring and autumn than in summer.

호기성 고정생물막 반응기에서 기초 설계인자와 유출수의 성상 (The Basic Design Parameters and Effluent Characteristics for Aerobic Fixed Biofilm Reactor)

  • 박태주;송승구
    • KSBB Journal
    • /
    • 제7권3호
    • /
    • pp.235-245
    • /
    • 1992
  • 비표면적이 다른 media를 이용한 호기성 고정생물막공법에서 유기물부하율을 변화시키면서, 유출수의 성상과 활성슬러지의 설계인자가 호기성 고정생물막송법에 적용가능한지를 조사하였다. 유출수의 수질은 낮은 유기물부하율에서는 유출수의 농도가 비표면적에 따라 크게 변화하지 않았으나, 높은 부하율에서는 변화폭이 매우 크게 나타나으며, 비표면적별 유출수 농도를 보면 비표면적이 큰 경우가 유출수 농도가 낮았으며, 유입수농도가 클수록 유출수의 농도차이도 더 크게 나타났다. 동력학적 계수를 산출하기 위해 활성슬러지 공법의 모델을 고정생물막 공법에 적용시켜 본 결과 실험조건에서 실측 미생물 생산량과 계산된 미생물 생산량과의 차이는 COD를 기준으로 하였을 때가 더 잘 일치함을 알았다.

  • PDF

강원 영서지역 하수처리장이 수질에 미치는 영향 (Effect of Municipal Sewage Treatment Plant on Water Quality in Western Kangwon Area)

  • 허인량;최지용;김영진;정의호
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.235-240
    • /
    • 2005
  • The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were $88.9\%,\;80.6\%,\;90.7\%$ and T-P removal rates were $47.3\%,\;56.5\%,\;71.6\%,$ respectively. Also, BOD effluent leading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6 mg/l to 4.0 mg/l and T-P rose from 0.034 mg/l to 0.321 mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1 mg/l to 1.4 mg/l and T-P from 0.011 mg/l to 0.026 mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.

유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

S 하수처리장 반류수가 방류수 수질에 미치는 영향 (The Effect of Reject Water on the Water Quality of Effluent from S Sewage Treatment Plant)

  • 김미란;김경희;박해식;강동효;이제근
    • 한국환경과학회지
    • /
    • 제19권3호
    • /
    • pp.323-329
    • /
    • 2010
  • To acquire preliminary data for the control of total nitrogen (TN) in S sewage treatment plant, which processes merging food waste and sewage, the effect of reject water on the total nitrogen in the effluent was examined in this study. Water quality data for the plant during the winter period were applied to calculate the mass balance. It was calculated that at least more than 231 kg/d TN should be removed to control the TN concentration in the effluent. Assuming 18 ppm as the goal TN concentration in the effluent, about 941 kg/d TN should be removed from this plant. Approximately 10% more TN should be removed than at present to achieve this result. It was observed that dewatering the filtrate had a considerably greater effect on the total nitrogen in the effluent than the reject waters. The dewatered filtrate contained 1,399kg/d TN. The contribution of the dewatered filtrate to the TN concentration in the effluent was 0.183, which was 7 to 23 times greater than the other reject waters. In addition, the amount of total nitrogen from the reject water, with the exception of the dewatering filtrate, was lower than the amount of TN that should be removed from S sewage treatment plant. Therefore, it was concluded that one of the most effective methods for controlling the TN concentration in effluent was the removal of the TN contained in the dewatering filtrate.

우리나라 공공하수처리시설의 TOC 배출특성 및 관리방안 연구 (Characteristics of TOC in effluent discharge from public sewage treatment works in korea)

  • 정동환;최인철;조양석;안경희;정현미;권오상;박후원;신현상;허진
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.657-668
    • /
    • 2014
  • Under Korea's Enforcement Decree of the Framework Act on Environmental Policy amended in 2013, total organic carbon (TOC) is newly added as water quality parameter to assess organic pollution in water and aquatic ecosystem. To meet the TOC requirement and improve quality of effluent discharged into public watershed, it is also necessary to develop standards for TOC in effluent from public sewage treatment works (PSTWs). In this study, we reviewed the characteristics and removal efficiency of TOC in influent and effluent of PSTWs. The study found that phosphorus treatment process removed not only soluble phosphorus but also a portion of TOC remaining after the secondary treatment process. TOC concentration in effluent from PSTWs operated in tandem with industrial wastewater treatment work was higher due to influx of insoluble substances from the industrial wastewater treatment work. In order to lay a foundation for the management of TOC from PSTWs, it is necessary to carry out research on TOC from different perspectives. For example, studies on the generation mechanism of TOC and the impact of TOC on drinking water resources, assessment of effluent qualities through monitoring, and development of measures to control TOC for the preservation of aquatic ecosystem are needed.

백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(II) (Influences of Fish Farm on the Physicochemistry of Stream Water Quality in (Mt.) Paekun Area(II))

  • 박재현;우보명;김우룡;안현철
    • 한국환경복원기술학회지
    • /
    • 제4권1호
    • /
    • pp.32-40
    • /
    • 2001
  • Quantifications of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Paekun area were monitored seasonally and the following results were obtained. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, percentage of dissolved oxygen, total amount of cation, total amount of anion and total amount of ion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as eco-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장 개발의 영향 (Influences of Fish Farm Development on the Physicochemistry of Stream Water Quality in (Mt.) Paekun Area)

  • 박재현
    • 한국환경복원기술학회지
    • /
    • 제2권3호
    • /
    • pp.54-63
    • /
    • 1999
  • Quantifications of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around (Mt.) Paekun area were monitored by seasons and the following results were obtained. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. Negative effects on stream water quality was also observed by indications of increase in electrical conductivity and temperature of effluent water from the fish farm. Decreases of physicochemical indexes such as the amount of dissolved oxygen, percentage of dissolved oxygen and total amount of ion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as eco-friendly fish farm design be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

북천지역 자연학습 체험단지 조성을 위한 수질 환경성 조사 및 분석 (Investigation and Analysis of Water Quality Environmental for Preparing a Natural Learning and Experimental Area in Bukchun and Boundary)

  • 정종현;최석규;이종현;정덕영;이강우
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.11-22
    • /
    • 2002
  • This study analyzes the river system and water quality conditions of Bukchun in order to establish a basic plan for Preparing a natural learning and experimental area of environmental ecosystem in Bukchun, Gyeongju. It also tries to establish an integrated plan for water management of Bukchun stream based on water contaminants. In addition, after analysing the water quality at 13 points during the non-rainy season, the effluent of municipal wastewater was of relatively better quality with I ~ II grade, below the water quality standard of the river, except in points near Samsung apartments. However, analysing the Hyeongsangang and the effluent of Bomunho and Duckdongdam in rainy season, the water quality was II ~ III grade according to environmental standard. The water Quality of those samples was strongly dependent of non-point source.