• Title/Summary/Keyword: effluent charge

Search Result 21, Processing Time 0.021 seconds

The Effect of Industrial Waste Water Effluent Charge Reform (수질배출부과금제도 개선 방안 연구)

  • Min, DongKi
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.767-785
    • /
    • 2009
  • This paper studies the effect of industrial waste water effluent charge reform. The goal of the present effluent charge system is to use environmental resources in an efficient way by charging the cost for removing emitted water pollutants. However, the present system is a type of regulation instead of providing economic incentives to the industry. That is, if a firm emits pollutants greater than the limit, it has to pay an amount greater than the cost of cleaning them taking into account the amount of waste water discharged, region, the number of violation and the level of density of pollutants. However, the excessive fees have resulted in the lowest ratio of revenue-to-effluent charge among all environmental charges. The paper estimates the effect of the change in effluent fee and revenue when the present effluent charge system is converted to one that offers economic incentives. The results show that the amount of waste water effluent charge is about four times larger than the estimated environmental cleaning cost. In addition, the results show that by modifying the effluent charge system, the ratio of revenue to effluent charge can be raised.

  • PDF

Effect of coagulation conditions on ultrafiltration for wastewater effluent

  • Maeng, Sung Kyu;Timmes, Thomas C.;Kim, Hyun-Chul
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.185-199
    • /
    • 2017
  • Low-pressure membrane filtration is increasingly used for tertiary treatment of wastewater effluent organic matter (EfOM), mainly comprising organic base/neutral compounds. In-line coagulation with underdosing, charge neutralization, and sweep floc conditions prior to ultrafiltration (UF) was studied to determine removals of the EfOM components and consequent reduction of fouling using polyethersulfone membranes. Coagulation and UF substantially reduced fouling for all coagulation conditions while removing from 7 to 38% of EfOM organic acids. From 7 to 16% of EfOM organic base/neutrals were removed at neutral pH but there was no significant removal for slightly acid coagulation conditions even though fouling was substantially reduced. Sweep floc produced the lowest resistance to filtration but may be inappropriate for in-line use due to the large added volume of solids. Charge-neutralization resulted in poor recovery of the initial flux with hydraulic cleaning. Under-dosing paralleled sweep floc in reducing hydraulic resistance to filtration (for sub-critical flux) and the initial flux was also easily recovered with hydraulic cleaning. Hydrophobic and hydrophilic base/neutrals were identified on the fouled membranes but as previously reported the extent of fouling was not correlated with accumulation of organic base/neutrals.

A Study on the Improvement of Effluent Treatment from Small Scale Agro-food Processes (소규모 농산가공시설 배출수 처리시설 개선방안)

  • Kim, Youngjin;Jeon, Jonggil;Kim, Minyoung;Choi, Yonghun
    • Journal of Agricultural Extension & Community Development
    • /
    • v.23 no.4
    • /
    • pp.361-374
    • /
    • 2016
  • This study examined the regulation status on wastewater treatment in agro-food processing and a case study on effluent treatment m ethods was carried out to evaluate any change after the mitigation of regulation. First, in order to clarify the area of investigation, the definition of small-scale agro-processing facilities was reviewed through literature survey and local government ordinance. The current law were separately analyzed into four areas; effluent treatment facilities, development of agro-processing industries, land use and food processes equipment. The exclusion clauses on wastewater discharging facility in the enforcement regulation were defined in detail, which can be served in practice. Site survey, after the questionnaire survey of the person in charge of the local unit, was carried out. As the result, this survey confirmed the positive effects of the deregulation on promoting sewer system service in rural areas, introducing the new processing construction and so on. In addition, it was found that some matters to be considered to determine whether to introduce wastewater treatment plan for public food processing facilities.

Stable Desalination of Hardness Substances through Charge Control in a Capacitive Deionization System (축전식 탈염 시스템에서 전하량 제어를 통한 경도물질의 안정적인 탈염)

  • Kim, Yoon-Tae;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.472-478
    • /
    • 2019
  • A stable desalination method of the hardness substance such as $Ca^{2+}$ by controlling the total charge (TC) supplied to the membrane capacitive deionization (MCDI) cell was studied. The adsorption (1.5 V) and desorption (0.0 V) were repeated 30 times while varying the TC in the adsorption process. The concentration and pH of effluent, adsorption and desorption amounts, current densities and cell potentials were analyzed in the desalination process. The maximum allowable charge (MAC) of the carbon electrode used in MCDI cell was measured to be 46 C/g. As a result of operation at TC (40 C/g) below the MAC value, electrode reactions did not occur, resulted in the stable desalination characteristics for a long-term operation. When operating at TCs (50, 60 C/g) above the MAC value, however, the concentration and pH of effluent varied greatly. Also, the scale was formed on the electrode surface due to electrode reactions, and the electric resistance of the cell gradually increased. It was thus concluded that it is possible to remove stably the hardness substance without any electrode reactions by controlling the charge supplied to MCDI cell during the adsorption process.

Inverted-U curve for material consumption of China industrial system: a new implication from environmental regulation

  • Fang, Yiping
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.237-255
    • /
    • 2012
  • We review the research literature on relationship between environmental regulation and industrial development in three aspects of environmental regulation and investment, environmental regulation and efficiency, environmental regulation and trade. Indeed, the linkage between environmental regulation and material consumption of industrial system is absent. Environmental regulation is measured as the expenditure share for industrial pollutants abatement, and effluent charge intensity. Using panel-level data from 31 provinces, municipalities and autonomous regions in China, we build correlation models between material consumption and environmental regulation, results show that: (1) there are significant quadratic function relationship between material consumption and environmental regulation. And there is the fact that inflection point exists. (2) On basis of inflection points, we make two remarkable reflections. Firstly, the inflection points are the most important scale to judge reasonability and performance of regulations. Secondly, a Pareto improvement may occur when the regulations achieve a certain target. (3) Both intensities of industrial pollutants abatement expenditure and effluent charge have not yet achieved the expected target in most regions of mainland China at present. And most of regions of material consumption decreasing are distributed in western China. Main reasons lie in the impacts of industrial features as well as the regulations.

Alum Floc Attachment in Granular Media Filtration (입상여과에서 액반플럭의 부착)

  • Kim, Jinkeun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.625-630
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and alum coagulation was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration when zeta potential of particles and collectors are both negative. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPDs of the effluent moved from more positive to less positive when the surface charge of particles was positive and this result was thought to be caused by ion transfer between particles and collectors.

Particle Attachment in Granular Media Filtration (입상여과에서 입자물질의 부착)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.666-672
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and pH control was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPD of the effluent did not keep moving from less negative to more negative during the later stages of filtration, and this result was thought to be caused by two reasons: ripening effects and the detachment of flocs.

Nitrogen and Phosphorus Removal Efficiency of Aluminum Usage in DEPHANOX Process (DEPHANOX 공정 내 알루미늄 첨가에 따른 질소 및 인 제거 효율 평가)

  • Lee, Beom;Park, Noh-Back;Tian, Dong-Jie;Heo, Tae-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.295-303
    • /
    • 2012
  • Removal of total nitrogen (T-N) and total phosphorus (T-P) was evaluated in a DEPHANOX process by adding Al(III) to the separator to maintain T-P in the final effluent below 0.2 mg/L. pH in each reactor was maintained 7~8 after addition of Al(III) to the levels of 5, 10, 15 mg/L. The removal efficiency of COD and T-N decreased at higher Al(III) dose, but T-P removal efficiency increased from 76.28 to 84.02, 94.66% at Al(III) dose of 5, 10, 15 mg/L, respectively. T-P in effluent showed 0.17 mg/L at Al(III) dose of 15 mg/L. Minimum 15 mg/L of Al(III) was required to maitain T-P below 0.2 mg/L in the final effluent.

전기부상법을 이용한 토양세정 유출수 중 유수분리에 관한 연구

  • 소정현;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.99-102
    • /
    • 2002
  • 전기분해에 의한 부상현상을 이용하여 토양세정 후 발생되는 유출수 중의 유수를 분리하기 위한 적정 운전조건에 관하여 고찰하였다. 전압에 의한 유수분리 효율을 관찰한 결과, 전기분해 1시간 후 3V의 전압만으로도 88% 정도의 제거율을 나타내었으며 6V 이상의 전압에서는 90% 정도로 거의 비슷한 제거율을 나타내어 대부분의 에멀젼이 분리됨을 확인할 수 있었다. 동일조건에서는 전기분해 시간이 경과될 수록 분리효율이 향상되었으며, 전극 간격이 넓어질수록 같은 효율을 얻기 위해 소요되는 전압의 크기가 커짐을 알 수 있었다. 전기분해 시 양극에서는 OH$^{-}$의 방전으로 발생되는 산소에 의해 산화반응이 일어나며, 음극에서는 H$^{+}$가 방전되어 발생되는 수소에 의해 환원반응이 일어나며 미세한 기포가 형성된다. 유분의 부상분리 현상은 유분의 (-)charge와 전기분해에 의해서 발생되는 양이온의 결합으로 인한 중화반응 및 음극에서 발생되는 미세 수소기포로 인만 부상분리가 대부분을 차지하며, 전압 및 전기분해 시간이 증가하고 전극 간격이 좁을수록 음극에서 발생되는 미세기포의 양이 증가되어 부상효과가 크게 나타나는 것으로 판단된다. 전극 종류는 구리 > 알루미늄 > 철 > 티타늄 순으로 효율을 나타내었으며, 이는 양극으로 사용된 이러한 금속들의 전기전도도 차이에 의해 일어나는 현상으로 판단된다

  • PDF

Selectivity and structural integrity of a nanofiltration membrane for treatment of liquid waste containing uranium

  • Oliveira, Elizabeth E.M.;Barbosa, Celina C.R.;Afonso, Julio C.
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.231-242
    • /
    • 2012
  • The performance of a nanofiltration membrane for treatment of a low-level radioactive liquid waste was investigated through static and dynamic tests. The liquid waste ("carbonated water") was obtained during conversion of $UF_6$ to $UO_2$. In the static tests membrane samples were immersed in the waste for 24, 48 or 72 h. The transport properties of the samples (hydraulic permeability, permeate flow, selectivity) were evaluated before and after immersion in the waste. In the dynamic tests the waste was permeated in a permeation flow front system under 0.5 MPa, to determine the selectivity of NF membranes to uranium. The surface layer of the membrane was characterized by zeta potential, field emission microscopy, atomic force spectroscopy and infrared spectroscopy. The static test showed that the pore size distribution of the selective layer was altered, but the membrane surface charge was not significantly changed. 99% of uranium was rejected after the dynamic tests.