• 제목/요약/키워드: effluent

검색결과 1,971건 처리시간 0.029초

생물전기화학기술을 이용한 하수처리장 방류수 수질개선 가능성 (Potential of a Bioelectrochemical Technology for the Polishing of Domestic Wastewater Treatment Plant Effluent)

  • 송영채;오경근
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.351-359
    • /
    • 2015
  • The study on the improvement of discharge water quality from domestic wastewater treatment plant (DWTP) was performed in a filter type bioelectrochemical system. The COD removal efficiency for a synthetic discharge water was about 88%, and the effluent COD was less than 5mg/L. The nitrification efficiency of the bioelectrochemical system was over 97%, but a considerable amount of the nitrogen was remained as nitrate form in the effluent. The total nitrogen removal efficiency was only around 30%. There are no significant differences in the removal of COD and nitrogen at 0.6 and 0.8V of the applied voltages between anode and cathode. The removal of COD and nitrogen in the system were quite stable when the HRT ranged from 60 to 15 minutes, and at 10 minutes of HRT, the nitrification efficiency was slightly decreased. The performance of the bioelectrochemical system has quickly recovered from the shocks in the influent due to high concentration of COD and nitrogen. For the effluent that discharged from the DWTP, the removal efficiencies of COD and total nitrogen from the bioelectrochemical system were 50 and 30%, respectively. Thus the bioelectrochemical system was a feasible process for further polishing the effluent quality from DWTP.

온수방류의 귀환에 방류구 길이의 영향 (Effect of Length of Outfall Structure on Reattachment of Thermal Discharge)

  • 윤태훈;육운수;이용균
    • 물과 미래
    • /
    • 제27권3호
    • /
    • pp.123-134
    • /
    • 1994
  • 돌출방류수로에 의하여 동일한 수심의 개수로에 방류되는 부력방류에 의한 연안귀환이 수리실험에 의하여 해석되었다. 부력방류는 온수를 방류하여 발생된다. 돌출방류로 인하여 부력류 하류에 형성되는 재순환영역의 크기는 비돌출방류에서 보다 증가하는 경향을 갖으나 황온도분포는 균일하고 횡단면 최대온도는 감소를 나타낸다. 높은 부력흐름율과는 반대로 낮은 부력흐름율 조건에서 단면평균온도 또는 열흐름율은 돌출길이의 영향이 무시할 정도이다. 비돌출의 경우에는 연안귀환에 유속비가 지배적인 매개변수이었으나 돌출방류의 경우에는 유속비와 후르드수가 다같이 지배적인 인자로 나타났다.

  • PDF

Electrochemical Degradation of Textile Effluent Using PbO2 Electrode in Tube Electrolyzer

  • Chao Wang; Yongqiang Li;Junmin Wan;Yi Hu;Yi Huang
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.190-197
    • /
    • 2024
  • A commercial PbO2 mesh cylinder electrode was utilized as the anode for the electrochemical degradation of the textile effluent after the biological treatment with the titanium cylinder as the cathode in a self-made tube electrolyzer. The electrochemical performances of the PbO2 electrode in tube electrolyzer under different initial pH, electrolyte flow rates, current densities and times of the electrochemical degradation were investigated. The experimental results illustrated that the PbO2 electrode can reduce the chemical oxygen demand (COD) of the textile effluent from 94.0 mg L-1 to 65.0 mg L-1 with the current efficiency of 88.3%, the energy consumption of 27.7 kWh kg-1 (per kilogram of degraded COD) and the carbon emissions of 18.0 kg CO2 kg-1 (per kilogram of degraded COD) under the optimal operating conditions. In addition, the COD of the textile effluent could be reduced from 94.0 mg L-1 to 22.0 mg L-1 after the fifth electrochemical degradation. Therefore, PbO2 mesh cylinder electrode in the tube cylinder was promising for the electrochemical degradation of the textile effluent.

유역하수도에서 강화된 방류수 수질 준수농도 적용을 위한 진위천수계 수질영향 평가 (A Study on Impact Assessment for Application of Strengthened Compliance Concentration of Effluent Limit from PSTWs in the Jinwee-stream Watershed)

  • 정동환;조양석;안기홍;류지철;안경희;정현미;권오상
    • 환경영향평가
    • /
    • 제24권5호
    • /
    • pp.397-406
    • /
    • 2015
  • 2013년 시행된 유역하수도정비계획에서는 유역별 수질상황을 고려하여 하수처리시설별 방류수 수질 준수농도(기준)를 별도로 적용하는 것이 가능하다. 유역의 중권역 목표기준 또는 수질오염총량관리 목표수질을 달성하기 위하여 유역하수도 제도 도입에 따라 유역 내 지역별 시설규모별 하수처리시설에 대한 방류수 수질 준수농도(안)을 설정하는 것이 필요하다. 유역환경청에서 수립하고 있는 유역하수도정비계획 수립 시 공공하수처리시설 방류수 수질 준수농도(기준)을 설정하는데 있어 II지역인 미호천유역의 경우 BOD 5 mg/L에서 3 mg/L, II III지역이 혼재되어 있는 영산강 상류유역의 경우 BOD 5~10 mg/L에서 3 mg/L로, IV지역인 안성천유역의 경우 BOD 10 mg/L에서 5 mg/L로 일률적으로 강화하도록 계획하고 있다. 이렇게 일률적으로 정하고 있는 준수농도에 대해 하수 처리기술, 유역특성을 고려한 유역하수도 공공하수처리시설의 방류수 수질 준수농도를 설정하는 방법을 제시하는 것이 필요하다. 본 연구에서는 공공하수처리시설 방류수 수질 준수농도 강화(안)을 설정할 때 이 강화된 준수농도가 공공수역 수질에 미치는 영향을 평가하여 어떤 강화(안)이 유역관리에 좀 더 효과적인지 고찰하였다.

제주 양식장 유입수과 방출수에서 분리한 다제내성 Vibrio균 플라스미드 프로파일링 (Plasmid profiling of multi-drug resistant Vibrio sp. isolated from influent and effluent water samples of fish farms in Jeju, South Korea)

  • 파루크 아딜;운노타쯔야
    • 미생물학회지
    • /
    • 제54권1호
    • /
    • pp.53-59
    • /
    • 2018
  • 이 실험은 제주도내 양식장으로부터 유입수와 방출수의 다제내성(MDR)을 가진 Vibrio 균의 plasmid profiling을 위해 진행하였다. Plasmid profiling을 위해 사용한 다제내성을 가진 균주는 디스크 확산법을 통해 확인하였고, 유입수와 방출수으로부터 각각 150개의 Vibrio 균주를 분리하였다. 모든 다제내성 균주를 대상으로 plasmid profiling을 실시하였으며, 유입수와 비교하여 방출수에서 많은Vibrio 균이 열거되었다(유입수 39%, 방출수 61%). 방출수에서는 neomycin, sulfamethoxazole, amoxicillin 및 oxytetracycline의 내성을 가진 균주가 유의적으로 많은 것으로 확인되었고, 대조적으로 Vibrio 균주는 florfenicol, chloramphenicol, ciprofloxacin 및 nalidixic acid에 더 민감한 것으로 확인이 되었다. 99종의 다제내성 균주(유입수 39종과 방출수 60종) 중에서 총 58종(유입수 38종과 방출수 20종)이 1.7 kb에서 10 kb 이상의 플라스미드를 가지고 있는 것을 확인하였으며 플라스미드 크기마다 19가지의 다른 다제내성 패턴을 보였다. 6종의 유입수와 4종의 방출수에서 다제내성 균주는 특이적인 plasmid profile이 확인되었다. 방출수 샘플은 보다 많은 플라스미드를 가진 다제내성 Vibrio 균주와 다양한 plasmid profile들과 다제내성 패턴을 가지고 있었고 이는 양식장의 저장탱크가 항생제내성 유전자의 저장소 역할을 할 수 있다는 점을 시사한다. 양식장의 방출수에서 plasmid를 가진 다제내성 Vibrio 균주의 존재는 항생제 내성 유전자의 전파에 기여할 수 있으며 이로 인해 인간의 건강을 위협할 수 있다.

알루미늄 가공 공장 배출 방류수의 독성 원인물질 탐색 (Application of Toxicity Identification Evaluation Procedures for Toxic Effluents from the Aluminum Rolling Industry)

  • 나진성;이지호;김기태
    • 한국환경보건학회지
    • /
    • 제41권5호
    • /
    • pp.305-313
    • /
    • 2015
  • Objectives: The objective of this study is to identify toxicants causing acute toxicity in effluents from the aluminum rolling industry that violate the discharge limits in Korea. Methods: Whole effluent toxicity tests (WET) were conducted on effluent discharged from the aluminum rolling industry following the US EPA WET test methods. We collected effluent samples three times and evaluated acute toxicity by using Daphnia magna. We employed toxicity identification evaluation (TIE) procedures to identify toxicants causing toxicity in the effluent. Results: No specific chemical groups were identified in the seven different manipulations applied to the of wastewater effluent samples showing 1.3 toxic units (TU) according to the TIE phase I procedures. Water quality parameters for water hardness, electric conductivity and heavy metals (Mn) were 4,322 mg/l as $CaCO_3$, 11.39 mS/cm, and $5,551{\mu}g/l$, respectively. Considering water hardness and reference toxicity, high concentrations of Mn can be disqualified from the causative toxicants. Consequently, high ionic concentrations of $Na^+$(1,648 mg/l), $Ca^{2+}$(1,048 mg/l), $Mg^{2+}$(1,428 mg/l) and $SO_4{^{2-}}$(7,472 mg/l) were identified to be causative toxicants. Water hardness and electric conductivity exceed the $EC_{50}$ value obtained by biological toxicity tests using Daphnia magna. Conclusion: According to TIE procedures, high salt concentration is determined to be a major toxicant in the effluent of agro-industrial wastewater treatment plants receiving wastewater from the aluminum rolling industry.

활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교 (Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process)

  • 이동근;성기문;정미라;박성주
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율 (Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process)

  • 이동근;정미라;성기문;박성주
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

구미시 하수처리 방류수가 하류 하천 영양염류에 미치는 영향: 부하량 비교 (Effects of Gumi City Sewage Treatment Effluent in the Downstream Nutrient Matter: Comparison of Daily Loading)

  • 성진욱;이상팔;이재균;박제철
    • 한국환경과학회지
    • /
    • 제22권12호
    • /
    • pp.1643-1650
    • /
    • 2013
  • This study investigated water quality of effluents and stream from the sewage treatment plants located at Gumi Complex 4, Gumi, and Wonpyeong in Gumi. Downstream region was found to increase the concentration of nutrients for sewage treatment plant effluent. Both phosphorus and nitrogen were accounted most as soluble form. In particular, the high ratio of dissolved effluent of sewage treatment plants were investigated. In the streams, Phosphorus concentration was high during rainy season and nitrogen concentration was high in the dry season. Sewage treatment plant effluent was relatively less microbial activity and nutrient concentrations were higher in the winter. TN/TP ratio was the highest in the upstream region and the lowest in the sewage treatment plant effluent. The effect of the nutrient matter from a discharge of a sewage treatment plant on rivers varied depending on the size of the river and the treatment plant. However, the influence of the concentration was greater than that of flowrate. Sewage treatment plant effluent loads phosphorus, nitrogen accounted for 8% and 6% respectively at the point N3 of the Nakdong river.

백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(III) (Influences of Fish Farm on the Physicochemistry of Stream Water Quality in Mt. Baegun Area(III))

  • 박재현
    • 한국환경복원기술학회지
    • /
    • 제4권4호
    • /
    • pp.46-55
    • /
    • 2001
  • Analysis of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Baegun area were monitored seasonally for three years. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. As a result of regression analyses, the linear equation of pH of influent and effluent water of fish farm was, pH of effluent water of fish farm = $0.6234{\times}pH$ of influent water of fish farm + 2.6263. Also, the linear equation of electrical conductivity of influent and effluent water of fish farm was electrical conductivity of effluent water of fish farm = $1.7275{\times}$electrical conductivity of influent water of fish farm - 14.007. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and water temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, total amount of cation and total amount of anion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as environmentally-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF