Operation Strategy for a Multi-functional Storage Facility (하수저류시설 운영 전략 연구)

  • Yun, So-Young;Lim, Yoon-Dae;Oh, Jei-ll
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.959-970
    • /
    • 2011
  • The frequent occurrence of sewer flooding and the intermittent discharge of non-point pollutions into the receiving water body are emerging issues recently due to the climate change and urbanization. These problems might be solved by introducing a multifunctional storage facility. Unlike a single-purpose storage facility, a multi-purpose storage facility should be operated at an instant to meet for flood prevention, reduction of non-point pollution and/or rainwater reuse. Considering various operational combinations it is suggested that prevention of sewer flooding coupled with reduction of non-point pollution is the most effective operational strategy for a multi-functional storage facility.

Development of sea water cooling apparatus for fish hold storage (어창용 해수 냉각장치 개발에 관한 연구)

  • 조영제
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.1
    • /
    • pp.60-64
    • /
    • 1999
  • The objective of this study was to manufacture the sea water cooling apparatus for fish hold storage to extend the freshness of fish. Using the sea water cooling apparatus manufactured, it makes observations on the physicochemical and sensual properties of mackerel such as ATP and its related compounds, K-value, VBN, TMA, TBA, salt-concentration and skin color through storage. The results of this investigation showed that the values of physicochemical properties such as ATP and its related compounds, K-value, VBN, TMA, TBA increased gradually during storage in sea water cooling apparatus manufactured and the changes of skin color was inhibited also. From these results, it could be suggested that developed sea water cooling apparatus is effective in shelf-life extension of fishes.

  • PDF

Security of Upland Irrigation Water through the Effective Storage Management of Irrigation Dams (관개용 댐의 효율적 저수관리를 통한 밭 관개 용수 확보)

  • Lee Joo-Yong;Kim Sun-Joo;Kim Phil-Shik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.2
    • /
    • pp.13-23
    • /
    • 2006
  • In Korea, upland irrigation generally depends on the ground water or natural rainfall since irrigation water supplied from dams is mainly used for paddy irrigation, and only limited amount of irrigation water is supplied to the upland area. For the stable security of upland irrigation water, storage level of irrigation dams was simulated by the periods. A year was divided into 4 periods considering the irrigation characteristics. Through the periodical management of storage level, water utilization efficiency in irrigation dams could be enhanced and it makes available to secure extra available water from existing dams without new development of water resources. Two study areas, Seongju and Donghwa dam, were selected for this study. Runoff from the watersheds was simulated by the modified tank model and the irrigation water to upland crops was calculated by the Penman-Monteith method. The analyzed results showed that relatively sufficient extra available water could be secured for the main upland crops in Seongju area. In case of Donghwa area, water supply to non-irrigated upland was possible in normal years but extra water was necessary in drought years such as 1998 and 2001.

Water Properties of Electrolytic Machine by Stainless Diaphragm and Effects of Electrolytic Ice Water Storage For Keeping Freshness of Squid, Todarodes pacificus (스테인레스 극판을 이용한 전해수장치의 수질특성과 오징어 선도유지를 위한 전해수 빙장 효과)

  • Lee, Nahme-Gull
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.293-301
    • /
    • 2006
  • This study was undertaken to prolonging the freshness in Squid(Todarodes pacificus) on the effects of ice storage methods(tap water ice, electrolytic water ice) using stainless diaphragm electrolytic instrument and also test an efficiency of instrument. Basically, stainless diaphragm electrolytic instrument studied for changes of pH on difference water flow and ampere. The lower water flower and higher ampere made low pH on acid part of electrolytic instrument. Squid samples were stored in tap water ice, acid part of electrolytic water and base part of electrolytic water and used in studying the changes of VBN and skin color through storage. Acid water had strong sterilization effects and VBN was lower levels of acid water than the others. Base water had not sterilization effects. Tap water ice storage was more sterilizing effects than base water ice storage but less effects than acid water ice storage. Lightness of Squid skin showed getting decrease at storage of ice water of all storage methods but acid water ice storage showed more retarding than the other two storage. From these results, it could be suggested that acid electric water ice storage is effective in extendance the shelf-life of squid at chilled storage.

Performance Tests on a Solar Water Heating System in Thermosyphonic Flow (열사이폰식 태양열 온수시스템의 성능실험)

  • Kim, Doo-Chun;Park, Seung-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.2
    • /
    • pp.93-103
    • /
    • 1980
  • A small domestic solar water heating system in thermosyphonic flow was tested in Seoul. The system consisted of four flat plate aluminium roll bond type collectors of total effective area $3.28m^2$ and a $280{\iota}$ storage tank. It was tilted $52^{\circ}$ relative to the horizon. And the collector plate, collector tube and storage tank were equiped with 14 thermocouples. As the results, the following facts were found; 1) To provide water at $55^{\circ}C$ for a family of four in Seoul, a collector area of $3-4m^2$ and a storage capacity of $180{\iota}- 200{\iota}$ are suggested. And this system can supply hot water at above $45^{\circ}C$ day about. 2) In the late afternoon hours, it might be advantageous to stop the flow in the system as heat losses to the environment increase unduly. 3) Without any hot water consumption throughout the day, water temperature distributions inside the storage tank was found almost linear. This indicates essentially no mixing inside the storage tank. 4) In case of a small domestic solar water heating system, it is better to employ a single transparent cover rather than double one.

  • PDF

Dynamic simulation of the ice storage cooling system (빙축열 냉방 시스템의 동적 시뮬레이션)

  • 한도영;이준호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.815-823
    • /
    • 1999
  • A dynamic simulation program may be used for the development of effective control algorithms for the ice storage cooling system. Simplified effective dynamic models for an ice-on-coil type storage tank, a screw chiller, a water-to-air heat exchanger, three way valves, pipes, pumps, temperature sensors, and controllers were developed. And a dynamic simulation program for the ice storage cooling system was developed by using these dynamic models. Control algorithms for the full storage system were also selected and analyzed in order to show the effectiveness of these models. From the simulation results, it may be concluded that the simulation program developed in this study can be effectively used for the development of improved control algorithms for the ice storage cooling system.

  • PDF

A Study on the Potential of Agricultural Water and Environmental Flow Supply according to Regulating Lower Control Storage Rate for the Irrigation Reservoir (농업용 저수지의 하한 관리 저수율 설정에 따른 농업용수 및 환경용수 공급 가능성 고찰)

  • Jeong, Jiyeon;Jeung, Minhyuk;Beom, Jina;Park, Minkyeong;Lee, Jaenam;Yoo, Seung-Hwan;Yoon, Kwang-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.21-33
    • /
    • 2023
  • While the main purpose of irrigation reservoirs is to supply agricultural water, the needs of environmental flow and flood control has been expanded. The agricultural reservoirs have been operated in the form of carry-over system until now. Therefore, the supply of agricultural water is difficult when the storage rate is not sufficiently secured after large volume of irrigation. In addition, there are regulation of the upper storage rate for some large reservoirs during the flood season, but lower storage rate is not regulated. Accordingly, this study aims to evaluate the capacity of agricultural water and environmental flow supply by setting the management lower storage rate of reservoir. The changes in the supply of agricultural and environmental flow was simulated according to the three different regulating lower storage rate scenarios. As a result, it was judged effective in terms of water supply managing the lower storage rate up to 30% when the initial storage rate of farming period is above annual average for the Naju reservoir considering existing water management practice. If the lower storage rate would have been controlled above 30%, the supply of agricultural water might be increased and non-effective discharge amount would be decreased compared to other scenarios during dry period of 2016-2018.

The effect of blast-induced vibration on the stability of underground water-sealed gas storage caverns

  • Zhou, Yuchun;Wu, Li;Li, Jialong;Yuan, Qing
    • Geosystem Engineering
    • /
    • v.21 no.6
    • /
    • pp.326-334
    • /
    • 2018
  • Underground water-sealed gas storage caverns have become the primary method for strategic storage of LPG. Previous studies of excavation blasting effects on large-scale underground water-sealed gas storage caverns are rare at home and abroad. In this paper, the blasting excavation for underground water-sealed propane storage caverns in Yantai was introduced and field tests of blasting vibration were carried out. Field test data showed that the horizontal radial velocity had a major controlling effect in the blasting vibration and frequencies would not cause the vibration velocity concentration effects. In terms of the influence of blasting vibration on adjacent caverns, the dynamic finite element model in LS-DYNA soft was established, whose reliability was verified by field test data. The numerical results indicated the near-blasting side was primary zone for the structural failure and tensile failure tended to occur in the middle of the curved wall on the near-blasting side. Meanwhile, the safety criterions for adjacent caverns based on stress wave theory and according to statistic relationship between peak effective tensile stress and peak particle velocities were obtained, respectively. Finally, with Safety Regulations for Blasting in China (GB6722-2014) taken into account, a final safety criterion was proposed.

Improvement of Storage Stability of Meatballs Using Propolis

  • Kim, Sung-kuk;Han, Sangmi;Kim, SeGun;Bang, Kyung Won;Choi, Hong Min;Moon, Hyo Jung;Woo, SoonOk
    • Journal of Apiculture
    • /
    • v.34 no.4
    • /
    • pp.325-328
    • /
    • 2019
  • We investigated the food storage stability of propolis extracts using homemade meatballs. Propolis extracts were prepared by using the ethanol extraction method. After making the meatballs, propolis was mixed into the meatball materials and egg water with a final concentration of 1% v/v. Microbial cultivation results showed that the cultivation of Staphylococcus aureus, which is one of the food poisoning bacteria, was reduced by more than 90% and the period of storage was 1.5 times longer. Also, it was observed to be effective when propolis was added to meatballs, it was even more effective when propolis was mixed with egg water. Thus, propolis extracts may be a useful ingredient for food storage stability due to its anti-microbacterial function.

A Study of Operation Standard and Method of Small Dams (소규모 댐의 운영기준 및 기법 연구)

  • Kim, Phil-Shik;Kim, Sun-Joo;Lee, Joo-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.260-265
    • /
    • 2005
  • The purpose of this study is to established a storage management method and operation standard for irrigation dams occupying the largest portion of small dams using storage management system. The system can be applied to seongju dam for effective management. The storage management method was established considering hydrology simulation and statistical analysis using the system. This method and operation standard are capable of analyzing additional available water, considering the water demand and supply of basin actually. It can improve the flood control capacity and water utilization efficiency by the flexible operation of storage space.

  • PDF