• Title/Summary/Keyword: effective index

Search Result 3,787, Processing Time 0.033 seconds

Analysis of Dielectric Rectangular Waveguide and Directional Coupler with Step Index Profile by the Modified Effective Index Method (수정된 실효 굴절율법에 의한 계단형 굴절률 분포를 갖는 광도파로와 방향성 결합기의 해석)

  • Kim, Chang Min;Jung, Byung Gi;Lee, Choang Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.4
    • /
    • pp.522-528
    • /
    • 1986
  • Based on the modified effective index method, analysis of dielectric rectangular waveguides and directional couplers are presented. Aside from the effective index concept of channel region, the equivalent index concept of cladding region is proposed. The error problem of eigenvalues, which has been experienced when the effective index method is used, is improved. Our approxiamtions give similar accuracy when compared with the results of other regorous approxiamtion techiniques. The advantage of the modified effective index methods is utilized by replacing the directional coupler with the equivalent slab guides, and the coupling constant is calculated by the coupled mode theory. The effectiveness of the equivalent index concept is positively confirmed.

  • PDF

Effective Refractive Index of Dye-Sensitized Solar Cell Using Transmittance and Reflectance Measurements (투과 및 반사율 측정을 이용한 염료감응태양전지의 유효 굴절률 모델링)

  • Kim, Hyeong Seok;Lee, Joocheol;Shin, Myunghun
    • Current Photovoltaic Research
    • /
    • v.3 no.3
    • /
    • pp.91-96
    • /
    • 2015
  • Optical modeling and characterization of transparent dye-sensitized solar cells (DSC) are presented to design and estimate DSC devices numerically. In order to model the inhomogeneous active layer of DSC, the porous structure of titanium oxide ($TiO_2$) and dye mixture, we prepared films consisting of layer by layer of the DSC's basic materials sequentially, and characterized the optical parameters of the films with the effective refractive index, which was extracted from the transmittance and reflectance measurements in ultra violet to near infra-red range. By using the effective refractive index, we made the optical model for DSC, and demonstrated that the optical model based on effective refractive index can be used to design and evaluate the performance of transparent-type DSC modules.

Analysis and Measurement of Effective Refractive Indices with Ion-exchanged Slab Waveguide (이온교환 평판도파로의 실효굴절율 측정 및 해석)

  • 천석표;박정일;박태성;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.73-76
    • /
    • 1995
  • In this study, the slab waveguide was fabricated using potassium-nitride(KNO$_3$) or silver-nitride (AgNO$_3$) molten sources by ion-exchange process. The effective refractive indices of waveguide were measured by Prism-Coupling method. and The characteristics of waveguide(mode dispersion, effective diffusion depth. surface refractive index, diffusion coefficient, and refractive index profile etc,) were investigated by WKB method, In the case of potassium ion-exchange, the computer calculation showed that the refractive index profile of waveguide followed Gaussian function, the surface refractive index increased with ion-exchange time and the effective diffusion depth increased a little as ion-exchange time increased, while the surface refractive index of silver ion-exchanged waveguide decreased with ion-exchange time because of the ion depletion on the surface of waveguide, and the effective diffusion depth seriously with ion-exchange tim. Double ion-exchanged waveguide was fabricated by performing silver ion-exchange after potassium ion-exchange. Double ion-exchanged waveguide had a tight mode binding force since the surface refractive index was larger than single step ion-exchanged waveguide.

  • PDF

Measurement of Effective Refractive Index of Nematic Liquid Crystal in Fabry-Perot Etalon

  • Ko, Myeong Ock;Kim, Sung-Jo;Kim, Jong-Hyun;Lee, Bong Wan;Jeon, Min Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.346-350
    • /
    • 2015
  • We report a measurement of the effective refractive index of a nematic liquid crystal (NLC) inside a Fabry-Perot (FP) etalon according to the applied electric fields. The effective refractive index of the NLC depends on the intensity of the applied electric field. A wavelength-swept laser with a polygon-scanner-based wavelength filter is used as a wide-band optical source to measure the effective refractive index of the NLC. The bandwidth of the optical source is greater than 90 nm around 1300 nm. The fabricated NLC FP etalon consists of glass substrates, gold layers as the electrodes with highly reflective surfaces, polyimide layers as the planar alignment layers, and an LC layer. Furthermore, we measured the Freedericksz transition voltages for three types of NLC FP etalons having thicknesses of $30.6{\mu}m$, $55.4{\mu}m$, and $108.8{\mu}m$. The Freedericksz transition voltages in the three cases are nearly equal. The measured effective refractive indices in the three cases decreased from 1.67 to 1.51 as the applied electric field intensity was increased. Beyond the threshold electric field, the effective refractive indices quickly decreased and eventually saturated at a value of 1.51 for all cases.

Developing the Nuclear Effective Safety Index (원자력 발전소 안전체감에 관한 연구: 안전체감지수 개발과 안전체감 수준)

  • Incheol Choi ;Beom Jun Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.13 no.3
    • /
    • pp.1-21
    • /
    • 2007
  • The present research was conducted 1) to explore the factor structure of 'effective safety' and 2) to develop an index of effective safety. We recuited a total of 800 residents of the nuclear plant sites and 187 nuclear plant employers. Study 1 developed a scale of nuclear effective safety which consisted of four factors: Communication, Trust, Coping Ability of nuclear power plants, Emergency Coping Skills. We created the index of effective safety by converting the scale scores into a number 0 to 100. Overall, the index was very low 38..22, indicating that the residents of nuclear power plants sites were feeling very insecure about the safety of nuclear power plants. Moreover we found a consistent pattern of regional and sex difference. In Study 2, we asked the employees of nuclear power plants to answer the scale as if they were the residents, and we compared these numbers with the numbers the actual residents provided. We found that the level of safety that the employees expected the residents to experience was significantly higher than the level of safety the residents were actually experiencing. We discussed the pratical implications of the present findings.

  • PDF

Development of Methodology of New Effective Installed Reserve Rate considering Renewable Energy Generators (신재생에너지전원을 고려한 새로운 유효설비예비율 평가방법의 개발)

  • Park, Jeong-Je;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper proposes a new effective installed reserve rate in order to evaluate reliability of power system considering renewable generators, which include uncertainty of resource supply. It is called EIRR(effective installed reserve rate) in this paper. It is developed with considering capacity credit based on ELCC by using LOLE reliability criterion. While the conventional installed reserve rate index yields over-evaluation reliability of renewable generators, the proposed EIRR describes actual effective installed reserve rate. However, it is not the probabilistic reliability index as like as LOLE or EENS but another deterministic effective reliability index. The proposed EIRR is able to evaluate the realistic contribution to the reliability level for power system considering wind turbine generators and solar cell generators with high uncertainty in resource supply. The case study in model system as like as Jeju power system size presents a possibility that the proposed EIRR can be used practically as a new deterministic reliability index for generation expansion planning or operational planning in future.

A Rigorous 2D Approximation Technique for 3D Waveguide Structures for BPM Calculations

  • Han, Young-Tak;Shin, Jung-Uk;Kim, Duk-Jun;Park, Sang-Ho;Park, Yoon-Jung;Sung, Hee-Kyung
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.535-537
    • /
    • 2003
  • We propose a rigorous 2D approximation technique for the 3D waveguide structures; it can minimize the well-known approximation errors of the commonly used effective index method. The main concept of the proposed technique is to compensate for the effective cladding index in the equivalent slab model of the original channel waveguide from the modal effective index calculated by the nonuniform 2D finite difference method. With simulations, we used the proposed technique to calculate the coupling characteristics of a directional coupler by the 2D beam propagation method, and the results were almost exactly the same as the results calculated by the 3D beam propagation method.

  • PDF

Measurement of Effective Refractive Index of Anodic Aluminum Oxide Using a Prism Coupler

  • Gong, Su-Hyun;Cho, Y.H.;Stolz, Arnaud;Gokarna, Anisha;Dogheche, Elhadj;Ryu, Sang-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.195-195
    • /
    • 2010
  • In recent years, Anodic aluminum oxide(AAO) has become popular and attractive materials. It can be easily fabricated and self-organized pore structures. It has been widely used as a biosensor membrane, photonic crystal for optical circuit and template for nanotube growth etc. In previous papers, the theory was developed that AAO shows anisotropic optical properties, since it has anisotropic structure with numerous cylindrical pores. It gives rise to the anisotropy of the refractive index called as birefringence. It can be used as conventional polarizing elements with high efficiency and low cost. Therefore, we would like to compare the theory and experimental results in this study. One method which can measure effective refractive index of thin film is the prism coupling technique. It can give accurate results fast and simply. Furthermore, we can also measure separately the refractive index with different polarization using polarization of the laser (TE mode and TM mode). We calculated the effective refractive index with effective medium approximations (EMAs) by pore size in the SEM image. EMAs are physical models that describe the macroscopic system as the homogeneous and typical method of all mean field theories.

  • PDF

A study on the enhancement of refractive index in Ti:LiTaO$_{3}$ optical waveguides by Zn-vapor diffusion (Zn-Vapor확산에 의한 Ti:LiTaO$_{3}$ 광도파로의 굴절률 증가에 관한 연구)

  • 정홍식;정영식
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.298-303
    • /
    • 1996
  • A double diffusion technique is developed to enhance the effective mode index of optical waveguides in $LiTaO_3$. It consists of Zn diffusion from the vapor phase at relatively low temperatures (750->$800^{\circ}C$), into waveguides initially produced by Ti indiffusion at higher temperature (1150->$1200^{\circ}C$). Both X- and Z-cut substrates are investigated. A model that combines profiles of both diffusion is formulated to calculate the expected effective index values for planar waveguides. Good agreement is found between experimental results and model predictions which assume that the initial Ti profile is not affected by the lower temperature Zn diffusion. Effective index enhancements as high as 0.005 and 0.003 are obtained by this method for the fundamental extraordinary and ordinary modes, respectively.

  • PDF

The Effects of Enzymatic Treatment on KOCC (효소처리가 KOCC의 특성에 미치는 영향)

  • 김대영;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.4
    • /
    • pp.34-40
    • /
    • 2000
  • This study was carried out to evaluate the effects of enzymatic treatment on the characteristics of KOCC. Novozym 342 and Pulpzyme HC were used for this purpose. Enzymatic treatment greatly increased the freeness of KOCC and Novozym 342 was more effective. WRV was improved only when KOCC was treated with 0.1% Pulpzyme HC. Pulpzyme HC was more effective to improve the flexibility of fiber(conformability angle) than Novozym 342. Coarseness of fiber was decreased with the enzymatic treatment. Fines content greatly decreased with 0.01% addition of enzymes. Novozym 342 was more effective than Pulpzyme HC for this purpose. Apparent density, tensile index and tear index decreased with enzymatic treatment, but stiffness increased. Especially the decrease of apparent density, tensile index and tear index by the treatment with Novozym 342 was significant than those of Pulpzyme HC. Therefore Novozym 342 will be suitable for the removal of fines and for bulky sheet, otherwise Pulpzyme HC will be good.

  • PDF