• 제목/요약/키워드: effective heat capacity model

검색결과 27건 처리시간 0.022초

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

단순모델에 의한 회전형 열교환기 이론해석 (Theoretical Analysis of a Rotary Heat Exchanger Based on a Simplified Model)

  • 손성균;김용찬;이대영
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.409-417
    • /
    • 2015
  • A simplified rotary heat-exchanger model was developed with an assumption of a linear temperature distribution along the flow direction. Based on the model, the exact fluid solution and solid temperature variations were obtained and verified from a comparison with previous numerical studies. The heat transfer in the rotary heat exchanger was investigated using the theoretical solutions. The heat exchanger's effectiveness was shown to be saturated, with a rotational-speed increase that is higher than a critical value that is solely dependent on the thermal capacity of the solid matrix but independent of the fluid flow rate; the saturated value of the effectiveness was determined only by the NTU of the heat exchanger. Where the thermal diffusivity of the solid matrix is so slight that the thermal penetration depth becomes smaller than the matrix thickness, the effective thermal capacity of the solid matrix decreased according to the penetration depth.

파이프라인이 매설된 폐쇄형 동결토의 동결심도 결정 (Determination of the Frozen Penetration Depth of a Freezing Soil Medium including a Pipeline in a Closed System)

  • 송원근
    • 한국전산구조공학회논문집
    • /
    • 제17권4호
    • /
    • pp.451-458
    • /
    • 2004
  • 본 연구는 동결토의 동결심도 및 매설된 파이프라인의 온도분포를 예측하기 위하여 유효열용량 개념 반영한 수치해석 모델의 개발에 초점이 맞추어져 있다. 이를 위하여 저자는 사용코드인 ANAQUS를 활용하여 파이프라인이 매설된 폐쇄형 시스템의 화강 동결토에 대하여 비정상 열전달 수치해석을 수행하였다. 제안된 수치해석 모델은 Frozen Fringe에서 간극수의 상변화 효과가 반영되었다. 제안된 수치해석 모델과 실내 실험으로부터 얻어진 결과들을 비교함으로써 유효열용량 모델의 적용성을 검증하였다.

Effects of Heat Processing Time on Total Phenolic Content and Antioxidant Capacity of Ginseng Jung Kwa

  • Oh, Chang-Ho;Kim, Gyo-Nam;Lee, Sang-Hyun;Lee, Jung-Sook;Jang, Hae-Dong
    • Journal of Ginseng Research
    • /
    • 제34권3호
    • /
    • pp.198-204
    • /
    • 2010
  • Korean ginseng (Panax ginseng C.A. Meyer) preserved in syrup, known as ginseng Jung Kwa (GJK), is a popular traditional snack in Korea. We investigated the effects of heat processing time on total phenolic content and antioxidant capacity of GJK. Water extract was prepared from GJK with different heat processing times, 3 hours (GJK-3), 6 hours (GJK-6), or 12 hours (GJK-12), with sonication for 2 hours. The GJK extract contained total phenolic content in the following order: GJK-12 (2.28%)>GJK-6 (1.57%)>GJK-3 (1.29%). Both the peroxy and hydroxyl radical-scavenging activity and cellular antioxidant capacity of GJK extract was significantly enhanced with increasing heat processing time. The hydroxyl radical-scavenging activity of GJK-12 extract was greater than that of the GJK-3 and GJK-6 extracts, consistent with metal chelating capacity and reducing capacity. In a cellular model, the GJK extract effectively reduced 2,2'-azobis(2-amidinopropane) dihydrochloride, $Cu^{2+}$-, and $H_2O_2$-induced oxidative stress, with GJK-12 and GJK-6 extracts demonstrating greater cellular antioxidant capacity than the GJK-3 extract. These results suggest that heat processing time can contribute to the antioxidant capacity of GJK and that GJK extract may have the potential to be used as an effective dietary antioxidant to prevent oxidative stress-related diseases.

전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법 (Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles)

  • 김대완;이무연
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.2545-2552
    • /
    • 2014
  • 본 연구에서는 전기구동 자동차에 동력원으로 사용되는 고전압 및 고용량 배터리의 고효율 운전을 위하여 배터리 열관리 시스템 기술을 소개하고 이론적 설계 방법에 소개하고 한다. 이를 위하여 전기구동 자동차의 배터리로 많이 사용되는 리튬이온 배터리의 고효율 운전을 위한 발열 모델링을 제시하였고, 열원의 종류에 따른 냉방 및 난방 시스템 설계를 에너지 평형식을 이용하여 부하를 계산하였다. 특히, 리튬이온 배터리의 발열 모델링을 이용하여 충전 및 방전 시 발열 반응열과 혹서기 및 혹한기시 배터리 작동의 최적 온도를 유지하기 위한 냉방과 난방 설계 기술을 제시하였다. 전기구동 자동차 종류에 따라 배터리 사용 비중이 다르기 때문에 효율적인 배터리 열관리를 위하여 계절별 및 작동 모드별 부하에 따른 배터리 열관리 기술을 제안하였다. 또한, 냉방 부하가 가장 큰 여름철 동일 조건에서 외부 공기 온도가 같다고 가정하면 냉방 능력은 수랭식 냉매 방법이 가장 크며 공랭식 방법이 가장 작게 나타난다.

340MWe급 순환 유동상 보일러의 단순 성능 예측 모형 (Performance Prediction Model of 340MWe Circulating Fluidized Bed Boiler)

  • 양종인;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.119-122
    • /
    • 2012
  • Circulating fluided bed(CFB) furnace which can use a variety of low-grade fuels because of high heat capacity and good mixing characteristic in its furnace have turned out to be effective system. There is no many research to predict performance considering total boiler system with water-steam side. Most of performance prediction model have focused on hydrodynamics or chemical mechanism in furnace. so, This study is aimed to develop performance prediction model which consider water-steam side.

  • PDF

Dry Room내의 온.습도 분포 해석 (Analysis of Temperature and Humidity Distribution in a Dry Room)

  • 이관수;임광옥;안강호;정영식
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.524-531
    • /
    • 2001
  • The temperature and humidity distribution in a dry room are studied numerically by using standard$\kappa-\varepsilon$ turbulence model. In order to evaluate effective heat and moisture ventilation characteristics inside the room, the heat removal capacity and moisture exhaust efficiency are introduced. An effective ventilation control is analyzed by evaluating quantitatively temperature and humidity distributions. It was found that the mean absolute humidity inside the room was almost constant with approximately 0.1905g/kg air regardless of the models and the heat generation rates. This was believed that the moisture generation by workers was relatively small. 40% improvement of the critical decay time was achieved, through the modifications of design variables.

  • PDF

TPS를 통한 열물성치 획득 및 네트워크모델을 이용한 열해석 (Measurement of thermal properties by TPS-technique and thermal network analysis)

  • 윤태섭;김영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.263-268
    • /
    • 2010
  • Thermal characterization of geomaterials has significant implication on the geothermal energy, disposal of nuclear wastes, geological sequestration of carbon dioxides and recovery of hydrocarbon resources. Heat transfer in multiphase materials is dominated by the thermal conductivity of consisting components, porosity, degree of saturation and overburden pressure, which have been investigated by the empirical correlation at macro-scale. The thermal measurement by Transient Plane Source (TPS) and associated algorithm for interpretation of thermal behavior in geomaterials corroborate the robustness of sensing techniques. The method simultaneously provides thermal conductivity, diffusivity and volumetric heat capacity. The newly introduced thermal network model enables estimating thermal conductivity of geomaterials subjected to the effective stress, which has not been evaluated using previous thermal models. The proposed methods shows the applicability of reliability of TPS technique and thermal network model.

  • PDF

선형열원 모델과 수정 DST(TRNVDSTP) 모델에 의한 지열 히트펌프 시스템 성능 예측 (Performance Prediction of Geothermal Heat Pump System by Line-Source and Modified DST(TRNVDSTP) Models)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.61-69
    • /
    • 2012
  • Geothermal heat pump(GHP) systems have been shown to be an environmentally-friendly, efficient alternative to traditional cooling and heating systems in both residential and commercial applications. Although some experimental work related to performance evaluation of GHP systems with vertical borehole ground heat exchangers for commercial buildings has been done, relatively little has been reported on the performance simulation of these systems. The aim of this study is to evaluate the cooling and heating performance of the GHP system with 30 borehole ground heat exchangers applied to an commercial building($1,210m^2$) in Seoul. For this purpose, a typical design procedure was involved with a combination of design parameters such as building loads, heat pump capacity, circulating pump, borehole diameter, and ground effective thermal properties, etc. The cooling and heating performance prediction of the system was conducted with different prediction methods and then each result is compared.

Postfire reliability analysis of axial load bearing capacity of CFRP retrofitted concrete columns

  • Cai, Bin;Hao, Liyan;Fu, Feng
    • Advances in concrete construction
    • /
    • 제10권4호
    • /
    • pp.289-299
    • /
    • 2020
  • A reliability analysis of the axial compressive load bearing capacity of postfire reinforced concrete (RC) columns strengthened with carbon fiber reinforced polymer (CFRP) sheets was presented. A 3D finite element (FE) model was built for heat transfer analysis using software ABAQUS. Based on the temperature distribution obtained from the FE analysis, the residual axial compressive load bearing capacity of RC columns was worked out using the section method. Formulas for calculating the residual axial compressive load bearing capacity of the columns after fire exposure and the axial compressive load bearing capacity of postfire columns retrofitted with CFRP sheets were developed. Then the Monte Carlo method was used to analyze the reliability of the axial compressive load bearing capacity of the RC columns retrofitted with CFRP sheets using a code developed in MATLAB. The effects of fire exposure time, load ratio, number of CFRP layers, concrete cover thickness, and longitudinal reinforcement ratio on the reliability of the axial compressive load bearing capacity of the columns after fire were investigated. The results show that within 60 minutes of fire exposure time, the reliability index of the RC columns after retrofitting with two layers of CFRPs can meet the requirements of Chinese code GB 50068 (GB 2001) for safety level II. This method is effective and accurate for the reliability analysis of the axial load bearing capacity of postfire reinforced concrete columns retrofitted with CFRP.