• 제목/요약/키워드: effective dose limit

검색결과 72건 처리시간 0.025초

Administrative dose control for occupationally-exposed workers in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Jung, Yoonhee;Kim, Jeong Mi;Cho, Moonhyung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.351-356
    • /
    • 2021
  • Korean nuclear power plants (NPPs) have various radiation protection programs to attain radiation exposure as low as reasonably achievable (ALARA). In terms of ALARA, this paper provides a comprehensive overview of administrative dose control for occupationally-exposed workers in Korean NPPs. In addition to dose limits, administrative dose constraints are implemented to resolve an inequity of radiation exposure in which some individuals in NPPs receive relatively higher doses than others. Occupational dose constraints in Korean NPPs are presented in this paper with the background of how those values were determined. For pressurized water reactors, 80% and 90% of the annual average limit for an effective dose, 20 mSv/y, are set as the primary and secondary dose constraints, respectively. Pressurized heavy water reactors (PHWRs) have also established the primary and secondary dose constraints corresponding to 70% and 80% of the effective dose limit, and additional constraints for tritium concentration are provided to control internal exposure in PHWRs. Follow-up measures for exceeding these administrative dose constraints are also introduced compared to exceeding the dose limits. Finally, analysis results of dose distributions show how the implementation of administrative dose constraints impacted the occupational dose distributions in Korean NPPs during the years 2009-2018.

몬테카를로 전산해석에 의한 X선 실습실의 공간선량분포 평가 (Assessment of Spatial Dose Distribution in the Diagnostic Imaging Laboratory by Monte Carlo Simulation)

  • 조윤형;강보선
    • 한국방사선학회논문지
    • /
    • 제11권6호
    • /
    • pp.423-428
    • /
    • 2017
  • 본 연구에서는 몬테카를로 전산해석법으로 K대학교 진료영상 촬영 실습실의 방사선 조사실과 발생장치 제어실 내부 공간 유효선량률 분포 계산을 수행하였다. 방사선 발생장치는 최대 관전압 150 kVp에 최대 관 전류 700 mA이다. 전산해석 결과를 이용하여 차폐문이 닫힌 경우와 열린 경우의 진료영상 촬영 실습실의 공간선량 분포를 비교 평가하였다. 결과적으로, 차폐문이 열린 경우에도 방사선 발생장치 제어실의 유효선량률은 학생(수시출입자)의 연간 유효선량률 한도(6 mSv/y)를 초과하지 않는다는 것을 알 수 있었다. 하지만, 차폐문이 열려있을 때의 유효선량률이 차폐문이 닫힌 경우에 비해 납유리 앞에서는 약 16배, 차폐문 앞에서는 약 3,000배 더 높기 때문에 실습 중에 차폐문을 닫는 것이 불필요한 방사선 피폭을 크게 줄인다는 것을 알 수 있었다.

Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산 (A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center)

  • 이창우;이정호
    • Journal of Radiation Protection and Research
    • /
    • 제15권2호
    • /
    • pp.75-85
    • /
    • 1990
  • Kalsruhe원자력 연구소(KfK) 주변의 방사능 측정자료로부터 피폭선량을 계산하였다. 식물성 식품의 섭취가 가장 중요한 피폭 경로였고, 식품중의 자연방사성 동위원소인 K-40 과 Pb-210이 주요 피폭원이었다. 인공방사능에의한 피폭은 대부분 지표에 침척된 Cs-134 와 Cs-137으로부터 방출되는 감마선 때문이었다. KfK주변환경에서의 유효선량당량은 ICRP의 권고제한치보다 훨씬 적은 값이었다.

  • PDF

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

Estimation of Effective Dose to Residents Due to Hypothetical Accidents During Dismantling of Steam Generator

  • Kyeong-Ju Lee;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제21권2호
    • /
    • pp.183-191
    • /
    • 2023
  • The potential impact of hypothetical accidents that occur during the immediate and deferred dismantling of the Kori Unit 1 steam generator has been comprehensively evaluated. The evaluation includes determining the inventory of radionuclides in the Steam Generator based on surface contamination measurements, assuming a rate of release for each accident scenario, and applying external and internal exposure dose coefficients to assess the effects of radionuclides on human health. The evaluation also includes calculating the atmospheric dispersion factor using the PAVAN code and analyzing three years of meteorological data from Kori NPP to determine the degree of diffusion of radionuclides in the atmosphere. Overall, the effective dose for residents living in the Exclusion Area Boundary (EAB) of Kori NPP is predicted, an it is found that the maximum level of the dose is 0.034% compared to the annual dose limit of 1 mSv for the general public. This implies that the potential impact of hypothetical accidents on human health discussed above is within acceptable limits.

Preliminary Evaluation of the Activity Concentration Limits for Consumer Goods Containing NORM

  • Jang, Mee;Chung, Kun Ho;Ji, Young Yong;Lim, Jong Myung;Kang, Mun Ja;Choi, Guen Sik
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.101-104
    • /
    • 2016
  • Background: To protect the public from natural radioactive materials, the 'Act on safety control of radioactive rays around living environment" was established in Korea. There is an annual effective dose limit of 1 mSv for products, but the activity concentration limit for products is not established yet. Materials and Methods: To suggest the activity concentration limits for consumer goods containing NORM, in this research, we assumed the "small room model" surrounding the ICRP reference phantom to simulate the consumer goods in contact with the human bodies. Using the Monte Carlo code MCNPX, we evaluate the effective dose rate for the ICRP reference phantom in a small room with dimension of phantom size and derived the activity concentration limit for consumer goods. Results and Discussion: The consumer goods have about 1600, 1200 and $19000Bq{\cdot}kg^{-1}$ for $^{226}Ra$, $^{232}Th$ and $^{40}K$, and the activity concentration limits are about six times comparing with the values of building materials. We applied the index to real samples, though we did not consider radioactivity of $^{40}K$, indexes of the some samples are more than 6. However, this index concept using small room model is very conservative, for the consumer goods over than index 6, it is necessary to reevaluate the absorbed dose considering real usage scenario and material characteristics. Conclusion: In this research, we derived activity concentration limits for consumer goods in contact with bodies and the results can be used as preliminary screening tool for consumer goods as index concept.

Detection Limit of a NaI(Tl) Survey Meter to Measure 131I Accumulation in Thyroid Glands of Children after a Nuclear Power Plant Accident

  • Takahiro Kitajima;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.131-143
    • /
    • 2023
  • Background: This study examined the detection limit of thyroid screening monitoring conducted at the time of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011 using a Monte Carlo simulation. Materials and Methods: We calculated the detection limit of a NaI(Tl) survey meter to measure 131I accumulation in the thyroid gland of children. Mathematical phantoms of 1- and 5-year-old children were developed in the simulation of the Particle and Heavy Ion Transport code System code. Contamination of the body surface with eight radionuclides found after the FDNPP accident was assumed to have been deposited on the neck and shoulder area. Results and Discussion: The detection limit was calculated as a function of ambient dose rate. In the case of 40 Bq/cm2 contamination on the body surface of the neck, the present simulations showed that residual thyroid radioactivity corresponding to thyroid dose of 100 mSv can be detected within 21 days after intake at the ambient dose rate of 0.2 µSv/hr and within 11 days in the case of 2.0 µSv/hr. When a time constant of 10 seconds was used at the dose rate of 0.2 µSv/hr, the estimated survey meter output error was 5%. Evaluation of the effect of individual differences in the location of the thyroid gland confirmed that the measured value would decrease by approximately 6% for a height difference of ±1 cm and increase by approximately 65% for a depth of 1 cm. Conclusion: In the event of a nuclear disaster, simple measurements carried out using a NaI(Tl) scintillation survey meter remain effective for assessing 131I intake. However, it should be noted that the presence of short-half-life radioactive materials on the body surface affects the detection limit.

Radon and thoron concentrations inside ancient Egyptian tombs at Saqqara region: Time-resolved and seasonal variation measurements

  • Salama, E.;Ehab, M.;Ruhm, W.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.950-956
    • /
    • 2018
  • For complete assessment of inhalation doses of radon and its progeny inside the three main ancient Egyptian tombs in Saqqara, seasonal radon concentrations have been measured by using a new electronic device that allows for measurement of real-time-resolved radon concentrations. Measurements were complemented by very fast measurements of thoron concentrations, which turned out to be low. Based on these measurements, annual residence time inside these tombs and the newest International Commission on Radiological Protection-recommended radon dose conversion coefficients or seasonal effective doses were calculated. The results indicate that workers receive highest annual effective doses of up to 140 mSv, which exceeds the annual limit of 20 mSv, whereas lower values up to 15 mSv are received by guides. In contrast, much lower doses were obtained for one-time visitors of the investigated tombs. The obtained results are somewhat different but still consistent with those previously obtained by means of fixed passive dose meters at some of the investigated places. This indicates that reasonable estimates of the effective dose of radon can be also obtained from short-term radon measurements carried out only twice a year (summer and winter season). Increasing the ventilation, minimizing the working times, etc., are highly recommended to reduce the annual effective dose.

Assessment of Internal Dose by $^3H\;&\;^{14}C$ of Total Diet for Inhabitants near Wolsung Nuclear Power Plants

  • Park, G.;Lin, X.J.;Kim, W.;Kang, H.D.;Doh, S.H.;Kim, D.S.;Kim, C.K.
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.51-57
    • /
    • 2003
  • To assess the internal dose by $^3H\;&\;^{14}C$ in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and $^{14}C$ concentration in total diet was analyzed for collection region and time. TFWT, OBT and $^{14}C$ concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.855 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and $^{14}C$ is $6.10{\times}10^{-5}mSv/y,\;3.71{\times}10^{-5}mSv/y\;and\;7.08{\times}10^{-3}mSv/y$, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about $7.18{\times}10^{-3}mSv/y$, which is about 0.72% of annual effective dose limit 1 mSv/y.

Level of radiation dose in university hospital non-insured private health screening programs in Korea

  • Lee, Yun-Keun
    • Environmental Analysis Health and Toxicology
    • /
    • 제31권
    • /
    • pp.7.1-7.6
    • /
    • 2016
  • Objectives The aim of this study is to evaluate radiation exposure resulting from the comprehensive health examinations of selected university hospital programs and to present basic data for research and management strategies on the health effects of medical radiation exposure. Methods Radiation-based diagnostic studies of the comprehensive health examination programs of ten university hospitals in Seoul, Korea, as introduced in their websites, were analyzed. The medical radiation studies of the programs were reviewed by radiologists. Only the effective doses of the basic studies were included in the analysis. The optional studies of the programs were excluded. Results Among the 190 comprehensive health examination programs, 132 programs (69.5%) included computed tomography studies, with an average of 1.4 scans. The average effective dose of radiation by program was 3.62 mSv for an intensive program for specific diseases; 11.12 mSv for an intensive program for cancer; 18.14 mSv for a premium program; and 24.08 mSv for an overnight program. A higher cost of a programs was linked to a higher effective dose (r=0.812). The effective doses of the examination programs for the same purposes differed by as much as 2.1 times by hospital. Inclusion of positron emission tomography-computed tomography was the most critical factor in determining the level of effective dose. Conclusions It was found that radiation exposure dose from comprehensive health exam programs targeted for an asymptomatic, healthy public reached between 3.6 and 24 times the annual dose limit for the general public. Relevant management policies at the national level should be provided to minimize medical radiation exposure.