• Title/Summary/Keyword: effective dose

Search Result 2,508, Processing Time 0.03 seconds

High and Low Dose Folinic Acid, 5-Fluorouracil Bolus and Continuous Infusion for Poor-Prognosis Patients with Advanced Colorectal Carcinoma

  • Bano, Nusrat;Najam, Rahila;Mateen, Ahmed;Qazi, Faaiza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3589-3593
    • /
    • 2012
  • Objective: Evaluation and assessment of response rate, duration and toxicity in patients subjected to 5-FU based chemotherapy. Background: The therapeutic ratio shifts with different 5FU/LV regimens and none yet serve as the internationally accepted Gold Standard. A bimonthly regimen of high dose leucovorin is reported to be less toxic and more effective than monthly low dose regimens. We here compare therapeutic responses and survival benefit of the two regimens in poor prognosis patients with advanced colorectal carcinoma. Patients and Methods: A total of 35 patients with histologically confirmed colorectal carcinoma were subjected to de Gramont and Mayo Clinic regimen. Nineteen patients were treated with high dose folinic acid ($200mg/m^2$), glucose 5%, 5-FU ($400mg/m^2$) and 22 hr. CIV ($600mg/m^2$) for two consecutive days every two weeks. These patients had failed responses to previous chemotherapy and were above sixty years of age with poor general status. Sixteen patients (six below 60 years) with progressive disease were subjected to low dose folinic acid ($20mg/m^2$)for five days, 5FU($425mg/m^2$) injection bolus for 5 days, every five weeks. An initial evaluation was made in sixty days and responders were reevaluated at sixty days interval or earlier in case of clinical impairment. Based on positive prognosis, the therapy was continued. Evaluation of treatment response was made on the basis of WHO criteria. Results: The response rate was 44% in thirty four evaluable patients, with 4 complete responses (11.8%) and 11 (32.4%) partial responses. The two schedules were well tolerated, whereas, mild toxicity without WHO Grade ${\geq}2$ events was assessed. The response duration was extended (12 months) in a few patients with age above sixty years treated by high dose bimonthly regimen of 5FU/LV. Conclusion: The regimens are safe and effective in advanced colorectal carcinoma patients with poor general status.

Improving the Accuracy of a Heliocentric Potential (HCP) Prediction Model for the Aviation Radiation Dose

  • Hwang, Junga;Yoon, Kyoung-Won;Jo, Gyeongbok;Noh, Sung-Jun
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • The space radiation dose over air routes including polar routes should be carefully considered, especially when space weather shows sudden disturbances such as coronal mass ejections (CMEs), flares, and accompanying solar energetic particle events. We recently established a heliocentric potential (HCP) prediction model for real-time operation of the CARI-6 and CARI-6M programs. Specifically, the HCP value is used as a critical input value in the CARI-6/6M programs, which estimate the aviation route dose based on the effective dose rate. The CARI-6/6M approach is the most widely used technique, and the programs can be obtained from the U.S. Federal Aviation Administration (FAA). However, HCP values are given at a one month delay on the FAA official webpage, which makes it difficult to obtain real-time information on the aviation route dose. In order to overcome this critical limitation regarding the time delay for space weather customers, we developed a HCP prediction model based on sunspot number variations (Hwang et al. 2015). In this paper, we focus on improvements to our HCP prediction model and update it with neutron monitoring data. We found that the most accurate method to derive the HCP value involves (1) real-time daily sunspot assessments, (2) predictions of the daily HCP by our prediction algorithm, and (3) calculations of the resultant daily effective dose rate. Additionally, we also derived the HCP prediction algorithm in this paper by using ground neutron counts. With the compensation stemming from the use of ground neutron count data, the newly developed HCP prediction model was improved.

Assessment of Effective Dose by using additional Filters in Dental Radiography: PC-Based Monte Carlo Program Analysis Subjected on Intraoral Radiography (치과 방사선 촬영의 부가 필터 사용에 따른 유효선량 평가: 구내 촬영에 대한 PC-Based Monte Carlo Program 분석)

  • Kwak, Jong Hyeok;Kim, A Yeon;Kim, Gyeong Rip;Cho, Hee Jung;Moon, Sung Jin;Kil, Sang Hyeong;Lee, Jong Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.491-498
    • /
    • 2021
  • In this study, the effective dose was measured using the PCXMC v2.0 program by examining the conditions used to set the diagnostic reference level for intraoral imaging recommended by the government, and the effect of the Al additive filter was confirmed. In oral imaging, the largest effective dose was calculated from the oral mucosa among 11 organs. The effect of the Al additive filter showed an excellent radiation reduction effect at 2mm rather than 1mm. In the case of children aged 5 years, the overall effective dose was calculated to be high in all 11 organs because they are more sensitive to radiation than adults. And as a result of evaluating the image quality according to the use of an additional filter during intraoral imaging, there was no significant difference in SNR and CNR changes compared to before the additional filter was used. Based on this study, it is thought that additional filter settings can be recommended for intraoral imaging.

Protective Effect of CFC-101, a Pseudomonas Vaccine, in Mice (마우스에서 CFC-101 (녹농균 백신)의 감염 방어효과)

  • 김영지;김제학;박완제;안동호;홍광희;김현수;김유삼;함경수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.322-325
    • /
    • 1994
  • To optimize the immunological efficacy of CFC-101, an outer-membrane protein vaccine purified from relatively less pathogenic 4 different Pseudomonas aeruginosa strains, we investigated to establish its dose, administration route, interval and frequency of vaccination in mice. As expected, the 4 CFC-101 producing strains were less pathogenic than the challenging organism, P. aeruginosa GN11189. CFC-101 completely protected the death caused by P. aeruginosa at above 0.05 mg/kg vaccinized by 3 times with 7-day intervals. At the optimally effective dose of 0.2 mg/kg of CFC-101, at least 3 immunizations were necessary for complete protection against P. aeruginosa-induced death. If immunized 3 times, the immunization interval could be shortened up to 2 days to acquire the best protection against P. aeruginosa. CFC-101 was effective either by intraperitoneal, subcutaneous or intramuscular but not by oral administration. The present results show that the newly developed Pseudomonas vaccine, CFC-101, is highly effective for the protection from death caused by pseudomonal infections.

  • PDF

Health Risk Assessment due to 137Cs Released into Ocean from the Severe Accident of the Fukushima Dai-ichi Nuclear Power Plants (후쿠시마 사고로 해양으로 누출된 137Cs에 의한 인체 위해도 평가)

  • Min, Byung Il;Lee, Baek Gun;Suh, Kyung Suk;Park, Kihyun
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.123-132
    • /
    • 2014
  • After the nuclear accident of the Fukushima Dai-ichi Nuclear Power Plants (FDNPPs) on 11 March 2011, a large amount of radioactive materials has been released into the atmosphere and the ocean. A compartment model is used to evaluate the circulation characteristics and the spatiotemporal concentration distributions of radionuclides in the ocean. In the comparison with observed concentrations of $^{137}Cs$ in seawater, calculated concentrations by the compartment model were well agreed with them. On the basis of these results, we performed evaluation of the effective dose and the cancer risk. In the early stage of the accident, the effective doses from ingestion of the seafood near the Fukushima region were much higher than 1 mSv which is the value of the annual effective dose limit to individual recommended by the International Commission on Radiological Protection (ICRP). However, the effective doses by ingestion of the seafood decreased below 1 mSv as distance from the FDNPPs increased and time passed. In addition, it was estimated that the cancer risks by intake of the contaminated marine products were less than natural occurrence probability of cancer. Consequently, it was inferred that the health risk due to the $^{137}Cs$ was low after since mid-term period of the accident.

Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes (LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석)

  • Kim, JoonBeom;Chung, Eun-Kyo;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

A Study of Clinical Efficacy of GnRH Antagonist (Cetrorelix) Single and Multiple Dose Protocol for Controlled Ovarian Hyperstimulation (과배란유도에서 GnRH Antagonist (Cetrorelix) Single 및 Multiple Dose Protocol의 임상적 효용성에 관한 연구)

  • Ko, Sang-Hyeon;Kim, Dong-Ho;Bae, Do-Hwan;Lee, Sang-Hoon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • Objective: This study was performed to compare the clinical outcomes of GnRH antagonist (Cetrorelix) single dose and multiple dose protocols for controlled ovarian hyperstimulation with GnRH agonist long protocol. Materials and Method: From September 2001 to March 2002, 48 patients (55 cycles) were performed controlled ovarian hyperstimulation for ART using by either GnRH antagonist and GnRH agonist. Single dose of 3 mg GnRH antagonist was administered in 15 patients (17 cycles, single dose group) at MCD #8 and multiple dose of 0.25 mg of GnRH antagonist was administered in 15 patients (18 cycles, multiple dose group) from MCD #7 to hCG injection day. GnRH agonist was administered in 18 patients (20 cycles, control group) by conventional GnRH agonist long protocol. We compared the implantation rate, number of embryos, and clinical pregnancy rate among three groups. Student-t test and Chi-square were used to determine statistical significance. Statistical significance was defined as p<0.05. Results: There were no significant differences in ampules of used gonadotropins, number of mature oocytes, obtained embryos between single and multiple dose group, but compared with control group, ampules of used gonadotropins, number of mature oocytes, obtained embryos were decreased significantly in both groups. Clinical pregnancy rate and implantation rate were not different in three groups. There were no premature LH surge and ovarian hyperstimulation syndrome in three groups. Multiple pregnancy were occurred 1 case in multiple dose group and 2 case in control group. Conclusions: GnRH antagonist is a safe, effective, and alternative method in the controlled ovarian hyperstimulation compared with GnRH agonist. Clinical outcomes and efficacy of both single and multiple dose protocol are similar between two groups.

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

The BIDAS Program : Bioassay Data Analysis Software for Evaluating Radionuclide Intake and Dose (BIDAS프로그램 : 방사성 핵종의 섭취량과 선량 평가용 생물학적분석 자료 해석 소프트웨어 프로그램)

  • Tae-Yong Lee;Jong-Kyung Kim;Jong-Il Lee;Si-Young Chang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.113-124
    • /
    • 2004
  • A computer software program, called BIDAS (BIoassay Data Analysis Software) is developed to interpret the bioassay measurement data in terms of intakes and the committed effective dose using the human respiratory tract model (HRTM), gastrointestinal tract (GI-tract) model and biokinetic models currently recommended by the International Commission on Radiological Protection (ICRP) to describe the behavior of the radioactive materials within the body. The program consists of three modules; first, a database module to manage the bioassay data, second, another databasee module to store the predicted bioassay quantities of each radionuclide and finally, a computational module to estimate the intake and committed effective dose calculated with the bioassay quantity measurement values from either an acute or chronic exposure of the radionuclies within the body. This paper describes the features of the program as well as the quality assurance check results of the BIDAS software program.

  • PDF