• Title/Summary/Keyword: effective dose

Search Result 2,494, Processing Time 0.03 seconds

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

조영제 사용 전${\cdot}$후 불균질 조직 보정 알고리즘에 따른 선량변화에 대한 연구

  • Kim, Ju-Ho;Jo, Jeong-Hui;Lee, Seok;Jeon, Byeong-Cheol;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.38-46
    • /
    • 2001
  • Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.

  • PDF

The Effects of Regular Injection of High Dose Vitamin C on Liver Damage in Paraquat Poisoned Rat Model - Prehospital Care Model - (백서의 paraquat 중독모델에서 고용량 Vitamin C의 주기적 투여가 간에 미치는 영향 병원전 처치 모델)

  • Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.10 no.1
    • /
    • pp.51-60
    • /
    • 2006
  • Background: The toxicity of paraquat has been known to be caused by oxygen free radicals which leads to the lipid peroxidation and multiple organ failure. High dose vitamin C has been known to be a effective antioxidant activities against the paraquat intoxication. This study was designed to evaluate the effect of regular injection of high dose vitamin C on liver damage in paraquat poisoned rat model. Method: Fifty five rats of Sprague-Dawley strain were divided into three groups: control group, only intraperitoneally injected saline; paraquat group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected saline; paraquat and vitamin C group, single dose intraperitoneally injected paraquat(24.5%, 40 mg/kg) and every 8 hours injected vitamin C(72 mg/kg). Rats were sacrificed on the 12 hours, 1st day, 2nd day, 4th day, 7th day after injection and liver tissue was obtained. H&E(Hematoxylin & Eosin) stain and Masson's trichrome stain for collagen fiber detection were undertaken. The results were observed using the microscope. Results: 1. There were no differences between control and experimental group at the 12hours after regular injection of high dose vitamin C. 2. There were significantly decreased liver damage in experimental group in the 1st day after regular injection of high dose vitamin C. 3. There were significantly increased recovery of liver damage with time in experimental group after regular injection of high dose vitamin C. Conclusion: These results suggest that regular injection of high dose vitamin C is effective in decreasing liver damage in paraquat intoxication.

  • PDF

X-band EPR dosimetry using minimum mass of tooth enamel for use in radiological accidents

  • Jae Seok Kim;Byeong Ryong Park;Han Sung Kim;In Mo Eo;Jaeryong Yoo;Won Il Jang;Minsu Cho;HyoJin Kim;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.123-131
    • /
    • 2024
  • Electron paramagnetic resonance (EPR) dosimetry for a tooth from an individual exposed is well known as retrospective dosimetry in radiological accidents. A major constraint of the conventional X-band tooth-EPR dosimetry is the necessity to extract the tooth of the exposed patient for dose assessment. In this study, to conduct the dose assessments of exposed patients through part-extraction of tooth enamel, the minimum detectable dose (MDD) of the tooth enamel was evaluated based on the amount of mass. Further, a field test was conducted via intercomparison using various dose assessment methods to verify the feasibility of X-band tooth-EPR dosimetry using the minimum mass of tooth enamel. The intercomparison results demonstrated that effective dose determination via X-band tooth-EPR dosimetry is reliable. Consequently, it was determined that the minimum mass of tooth enamel required to evaluate an absorbed dose above 0.5 Gy is 15 mg. Thus, EPR dosimetry using 15 mg of tooth enamel can be applied in the triage and initial medical response stages for patients exposed during radiological accidents. This approach represents an advancement in managing radiological accidents by offering a more efficient and less invasive method of dose assessment.

A Study for Dose-Reduction of Antipsychotics in Chronic Schizophrenics (만성 정신분열병 환자에서 항정신병약물 감량에 관한 연구)

  • Hwang, Tae-Yeon;Lee, Min Soo;Kim, Hyeong-Seob
    • Korean Journal of Biological Psychiatry
    • /
    • v.5 no.2
    • /
    • pp.263-277
    • /
    • 1998
  • Conventional high-dose antipsychotics tend to result in more side effects, negative symptoms and dysphoria, and at the same time lower the cognitive function which is already impaired in most schizophrenics. Florid psychotic symptoms, negative symptoms and cognitive impairment greatly impede psychosocial performance and eventual reintegration into society. The reduction of symptom and the improvement of cognitive funtions and social skills are therefore central to the psychiatric rehabilitation process. The purpose of this study was to evaluate the dose-reduction effects of antipsychotics on chronic schizophrenics prescribed conventional high-dose antipsychotics more than 1,500mg equivalent of chlorpromazine. Fifty-one chronic schizophrenics who maintained high-dose antipsychotics for more than three months were randomly assigned to two groups : 20 patients comprised the dose-maintaining group and 31 patients made the dose-reduction group. Over a sixteen weekperiod Positive and Negative Syndrome Scale(PANSS), Extrapyramidal Symptom(EPS), Nurses' Observation Scale for Inpatient Evaluation(NOSIE-30), Continuous Performance Test(CPT), Quality of Life(QOL), and haloperidol/reduced haloperidol blood levels were determined at the base line and after 2, 4, 6, 8, 12, 16 weeks to evaluate the dose reduction effects of high-dose antipsychotics. The results were as follows : 1) Dose-reduction is highly effective in reducing positive and negative symptoms, and general psychopathology. Effects were most prominent at 8, 12, 16 weeks. Among the dose reduction group, positive symptoms in positive symptom group and negative symptoms in negative symptom group were more reduced. 2 Extrapyramidal symptoms showed no significant difference between two groups. But the EPS was reduced time after time within two groups. 3) Hit rates of Continuous Performance Test, which indicate attentional capacity, increased significantly after dose reduction. 4) Haloperidol and reduced haloperidol blood levels decreased until the 4th week, after which they were constant. 5) Total scores of Nurses' Observation Scale for Inpatient Evaluation were unchanged between the two groups. But among the indices, social interest and personal neatness were improved in the dose-reduction group and retardation was aggrevated in the dose-maintaining group. 6) Total quality of life scores were unchanged between two groups. But in the dose maintaining group, satisfaction scores of attention, autonomy, and interpersonal relationship decreased progressively. These findings suggest that the dose reduction of antipsychotics for chronic schizophrenics on programs of high-dose antipsychotics were effective. Dose reduction should therefore be implemanted to spread the rehabilitation and improve quality of life for chronic schizophrenics.

  • PDF

Determination of Dose Distribution under Nonequivalent Condition by Prosthesis in Radiotherapy (방사선 치료시 인공고관절 삽입에 의한 불균질면에서의 선량분포 평가)

  • Lee, Joon-Il;Kim, Sung-Hwan
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.43-46
    • /
    • 1998
  • When a patient was irradiated with prosthetic hip, the dose distribution was changed according to inhomogeneous materials. The density, effective atomic number, and the composition of material had influence on absorbed dose distribution. In this study, the influence of inhomogeneous material(Ti) was measured using a polyethylene phantom, which consisted of various diameter of titanium, with film dosimetry. As a result, the backward dose showed 29.5% increas by backscattering, the forward dose showed 28% decreas by absorption, and the side dose showed 7% increas by scattering, when 25 mm diameter Ti was used. In addition forward dose was in inverse proportion to the thickness of prosthetic material. When the prosthetic hip of patient is in an irradiated field, we must carefully study the absorbed dose distribution.

  • PDF

Definition and Difference between Dose Equivalent and Equivalent Dose in Radiation Dose Measurement and Evaluation (방사선량의 측정, 평가에서 선량당량(dose equivalent)과 등가선량(equivalent dose)의 정의 및 차이)

  • Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 1993
  • In its recent recommendation No. 60(1990), ICRP has newly introduced several terminology which had not existed in its prior recommendation No. 26(1977). Of these, a newly defined quantity 'Equivalent Dose' replacing the 'Dose Equivalent' of the ICRU concept has been recommended to be adopted in the radiation protection programme. However, since the committee still uses the 'Dose Equivalent' and 'Equivalent Dose' in its several publications, it is likely to provoke unnecessary confusions and misuses in applying these two quantities. In this paper were described the definition and difference between these two quantities to help in understanding of these two quantitites among the person involved in the radiation protection activities.

  • PDF

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.