• Title/Summary/Keyword: effective case depth

Search Result 320, Processing Time 0.034 seconds

A Study on the Optimal Design Method of Reinforced Concrete Two Way Slabs (Direct Method에 의한 鐵筋콘크리트 二方向슬라브의 最適設計에 관한 硏究)

  • Kim, Yong-Hee;Lyu, Hong-Leal;Park, Moon-Ho
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.2
    • /
    • pp.97-105
    • /
    • 1984
  • We have, at present, found some studies on the optimum design of reinforced concrete about the simple slab but very few about the multi-story and multi-span slab. The aim of this study is to make a optimum design of coalesced beam and column slab constructure. Some results of the evaluation by using the optimalized algorithm that was developed in this study are as follows. 1. Slab was mainly restricted by the constraint of effective depth, bending moment, and minimum steel ratio; especially the effective depth was the preceding crifical constraint. In the optimum design of slab, therefore, the constraint about the minimum thickness should be surely considered. 2. This optimum design is good economy as much as some 3.4&~6.2% compared with the conventional design method. 3. In most case, it was converged by 3 to 6 iteratin regardless of the highest or lowest value and only in case of N=1 and case 1, there is a little oscillation after the 3rd iteration but it makes no difference in taking either the highest or lowest value because the range of oscillation is low as much as about 1.2% of the total construction cost. 4. In this study the result seeking for constraints that make no difference in the least cost design shows that shear stress and maximum steel ration may not be considered in it. 5. Bending moment was converged by one time iteration regardless of the initial value, while steel ratio, in most case, by two times because both bending moment and steel ratio are the fuction of effective depth.

  • PDF

Characteristics of Plasma Carburizing Process in Surface Hardening of SCM415 Steel (플라즈마 침탄 공정을 이용한 SCM415강의 표면 경화 특성)

  • Kim, Dae-Wook;Kim, Dong-Won;Lim, Byeong-Soo;Kim, Seuk-Buom
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.707-713
    • /
    • 1998
  • The influence of plasma carburizing process on the surface hardness of SCM415 low-alloy steel (0.15% C) was investigated under the various process conditions of gas composition. gas pressure, plasma current density. temperature and time. The effective case depth was found to depend on the amount of methan gas containing carbon. thus the deepest case depth and the uniform hardeness were obtained with the 100% methan gas. The case depth increased with the plasma current density. The effective plasma carburizing temperature of SCM415 steel was found to be higher than 85$0^{\circ}C$, and the case depth was proportional to the square root of carburizing time under the same current density. The bending fatigue strength of the plasma carburized specimen is' higher than those of as- received specimen or reheat-quenched specimen.

  • PDF

Analysis and Measurement of Effective Refractive Indices with Ion-exchanged Slab Waveguide (이온교환 평판도파로의 실효굴절율 측정 및 해석)

  • 천석표;박정일;박태성;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.73-76
    • /
    • 1995
  • In this study, the slab waveguide was fabricated using potassium-nitride(KNO$_3$) or silver-nitride (AgNO$_3$) molten sources by ion-exchange process. The effective refractive indices of waveguide were measured by Prism-Coupling method. and The characteristics of waveguide(mode dispersion, effective diffusion depth. surface refractive index, diffusion coefficient, and refractive index profile etc,) were investigated by WKB method, In the case of potassium ion-exchange, the computer calculation showed that the refractive index profile of waveguide followed Gaussian function, the surface refractive index increased with ion-exchange time and the effective diffusion depth increased a little as ion-exchange time increased, while the surface refractive index of silver ion-exchanged waveguide decreased with ion-exchange time because of the ion depletion on the surface of waveguide, and the effective diffusion depth seriously with ion-exchange tim. Double ion-exchanged waveguide was fabricated by performing silver ion-exchange after potassium ion-exchange. Double ion-exchanged waveguide had a tight mode binding force since the surface refractive index was larger than single step ion-exchanged waveguide.

  • PDF

The Study on Estimation Fatigue Limit in Induction Surface Hardened S45C Steel (S45C강의 고주파 열처리 표면경화재 피로한도 예측에 관한 연구)

  • 이수진;전형용;성낙원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.134-142
    • /
    • 1998
  • The effects of small hole defect size and effective case depth(ECD) on the four point bending fatigue limit of induction surface hardened S45C steel were investigated the fatigue limit evaluation of hardened materials is very difficult because of relations of the hardness gradient and residual stress. In this study, it was possible to characterize fatigue limit and fatigue life of induction surface hardened S45C steel in terms of the hole defect size and effective case depth(ECD) and quantitative evaluation of the fatigue limit with hole defects use Murakami's evaluation method and the range of evaluated values is a good accuracy compared with results.

  • PDF

A Study on Vacuum Cargurizing Developments (진공침탄(眞空浸炭) 열처리(熱處理) 기술개발(技術開發)에 관한 연구(硏究))

  • Lee, Sang-Gil;Kang, Sun-Bae;Jung, Byong-Ho;Kim, Han-Goon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.3
    • /
    • pp.13-20
    • /
    • 1990
  • SCM 21 and D.P steel were carburized in vacuum using prophane at a temperature ranging from 1228k to 1308k under a gas pressure ranging from 21.3kpa to 61.8kpa, and the following results were obrained. 1) D.P. steel has considerable efficiency in depressing the grain growth during the high temperature carburizing and it has fine structure even at 1268k for 14.4ks when carburizied. Therefore this steel is expected to be suitable for vacuum carburizing at a high temperature. 2) Case depth was increased as the carburizing temperature increases and it was 3.2mm at max, temperature of 1308k, for max, time of 14.4ks and under max, pressure of 61.8kpa. Thus vacuum-carburizing was considered effective for the materials which need case depth, which is necessary for machine structure use. 3) The rate of case depth of SCM 21 was faster than D.P. steel under same carburizing conditions and the increasing rate of the case depth was constant. 4) Case depth was increased as the gas pressure becomes high under same carburizing temperature. 5) Case carbon concentration, $C_s$, of SCM 21 obeys to a formula, $$C_s=kt^{1/2}+C_0$$ Where k is $2.15{\times}10^{-2}$($wt%.S^{-1/2}$) and this value is a little bit lower than that of SNCM 815.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Analysis of Variance of Paddy Water Demand Depending on Rice Transplanting Period and Ponding Depth (이앙시기 및 담수심 변화에 따른 논벼 수요량 변화 분석)

  • Cho, Gun-Ho;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.3
    • /
    • pp.75-85
    • /
    • 2021
  • This study evaluated variations in the paddy rice water demand based on the continuous changing in rice transplanting period and ponding depth at the four study paddy fields, which represent typical rice producing regions in Korea. Total 7 scenarios on rice transplanting periods were applied while minimum ponding depth of 0 and 20 mm were applied in accordance with maximum ponding depth ranging from 40 mm to 100 mm with 20 mm interval. The weather data from 2013 to 2019 was also considered. The results indicated that the highest rice water demand occurred at high temperature and low rainfall region. Increased rice transplanting periods showed higher rice water demand. The rice water demand for 51 transplanting days closely matched with the actual irrigation water supply. In case of ponding depth, the results showed that the minimum ponding depth had a proportional relationship with rice water demand, while maximum ponding depth showed the contrary results. Minimum ponding depth had a greater impact on rice water demand than the maximum ponding depth. Therefore, these results suggest that increasing the rice transplanting period, which reflects the current practice is desirable for a reliable estimation of rice water demand.

Palatal root resection of compromised maxillary first molars (구개근 절제술을 이용한 상악 제일 대구치의 치료)

  • Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.375-381
    • /
    • 2009
  • Purpose: Root resection can be a valuable procedure when the tooth in question has a high strategic value. The prognosis of root resection has been well documented in previous studies, but the results focused on the palatal root resection have not been discussed in depth. I represent here the short term effectiveness of palatal root resection of maxillary first molars. Methods: Palatal root resection was performed on maxillary first molars of three patients. All the palatal roots were floating state on the radiographic finding and showed full probing depth and purulent exudation at initial examination. Reduction of palatal cusp and occlusal table was performed concomitantly. Endodontic therapy was completed after root resection. Results: Compromised maxillary first molars were treated successfully by palatal root resection in 3 cases. The mobility of resected tooth was decreased a little bit. The probing pocket depth of remaining buccal roots was not increased compared to initial depth. All the patients satisfied with comfort and cost effective results and the fact they could save their natural teeth. Conclusions: Within the above results, palatal root resection is an effective procedure treating compromised maxillary first molar showing advanced palatal bone loss to root apex with or without pulp involvement when proper case selection is performed.

A Effective Generation of Protocol Test Case Using The Depth-Tree (깊이트리를 이용한 효율적인 프로토콜 시험항목 생성)

  • 허기택;이동호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1395-1403
    • /
    • 1993
  • Protocol conformance is crucial to inter-operability and cost effective computer communication. Given a protocol specification, the task of checking whether an inplementation conforms to the specification is called conformance testing. The efficiency and fault coverage of conformance testing are largely dependent on how test cases are chosen. Some states may have more one UIO sequence when the protocol is represented by FSM (Finite State Machine). The length of test sequence can be minimized if the optimal test sequences are chosen. In this paper, we construct the depth-tree to find the maximum overlapping among the test sequence. By using the resulting depth-tree, we generate the minimum-length test sequence. We show the example of the minimum-length test sequence obtained by using the resulting depth-tree.

  • PDF

Relationship between Corrosion in Reinforcement and Influencing Factors Using Half Cell Potential Under Saturated Condition (습윤 상태에서의 반전위를 이용한 철근 부식과 영향 인자 간의 상관성 분석)

  • Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • In this study, the correlation between the influencing factors on corrosion and Half Cell Potential(HCP) measurement was analyzed considering the three levels of W/C ratio, cover depth, and chloride concentration. The HCP increased with enlarged cover depth, so it was confirmed that the increment of cover depth was effective for control of corrosion. Based on the criteria, the case of 60mm cover depth showed excellent corrosion control with under -200mV, indicating increase of cover depth is an effective method for reducing intrusion of external deterioration factors. When fresh water was injected to the upper part of specimens, very low level of HCP was monitored, but in the case that concentrations of chloride were 3.5% and 7.0%, HCP dropped under -200mV. In addition, the case with high volume of unit binder showed lower HCP measurement like increasing cover depth. Multiple regression analysis was performed to evaluate the correlation between the corrosive influence factors and HCP results, showing high coefficient of determination of 0.97. However, there were limitations such as limited number of samples and measuring period. Through the additional corrosion monitoring and chloride content evaluation after dismantling the specimen, more reasonable prediction can be achieved for correlation analysis with relevant data.