• 제목/요약/키워드: effect zone

검색결과 2,553건 처리시간 0.04초

재순환역을 수반하는 동축분류예혼합화염에 관한 연구 (Stability of premixed double concentric jets flame with a recirculation zone)

  • 이등헌일;송규근
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.145-153
    • /
    • 1987
  • 본 논문에서는 예혼합동축분류화염에 있어서 재순환역 안으로의 기체(공기, 연료, 혼합기) 주입과 2차공기의 족회가 화염안정성, 화염형상 및 재순환역에 미치는 영향을 명확히 하였다.

시화공단 완충녹지대의 대기오염물질 저감 효과 분석 (Effect of Green Buffer Zone in Reducing Gaseous Air Pollutants in the Shiwha Industrial Area)

  • 송영배
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.90-97
    • /
    • 2006
  • The effects of a green buffer zone to protect a residential area from air pollution from industrial facilities and traffic was examined by analyzing the case of a green buffer zone in the Shiwha industrial complex. The green buffer zone is 175 m wide. The intent was to assess the dispersion patterns of atmospheric air pollutants and the reduction in concentration around the green buffer zone. To measure atmospheric sulfur dioxide$(SO_2)$ and nitrogen dioxide$(NO_2)$ concentration, badge-type passive samplers were used and set up at 76 locations in order to measure the concentration of air pollutants with respect to the spatial dispersion. The weighted mean values of $SO_2\;and\;NO_2$ concentration were $3\~57 ppb\;and\;18\~62 ppb$ and the differences among the green buffer zone, the industrial area and the residential areas were $0.7\~1.1 ppb$. Mean values of atmospheric concentrations of $NO_2$ were similar in industrial and, residential areas and the green buffer zone. Results of the study show that the effect of the green buffer zone on reducing the dispersion of air pollutants was very low. This study also recommends that micro-climate, i.e., wind direction should be considered as a factor for planning and design of green buffer zones.

용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 - (Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul -)

  • 김수현;최창규
    • 국토계획
    • /
    • 제54권2호
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

장대사면 내 억지말뚝의 억제효과 (현장 Case-Study 중심으로) (Reinforcing Effects of Micro-Piles in a high Cut Slope)

  • 정성윤;김경태;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.374-381
    • /
    • 2002
  • Several sensor systems are used to estimate the reinforceing effect of pile in hihg cut slopes, and to find a failure zone in slopes effectively. Inclinometer, extensometer and V/W sensor have shown a great potentiality to serve real time health monitoring of the slope structures. They were embedded or attached to the structures, we conducted field tests and test results have shown great solutions for sensor systems of Civil Engineering Smart Structures. This research is to seek for the relationships among the slope movement and the reinforceing effect of pile, and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the relationships. Also, the relationships between temperature and reinforceing effect of pile, and the strain distribution are estimated in this paper.

  • PDF

Modelling FCW 용착금속의 기계적 성질에 미치는 Si, Mn의 영향 (The effect of silicon and manganese on)

  • 양철웅;강춘식;김경중
    • Journal of Welding and Joining
    • /
    • 제8권2호
    • /
    • pp.27-39
    • /
    • 1990
  • The effect of silicon and manganese, in the ranges of 0.3% to 1.0wt% Si and 0.7 to 2.6wt%Mn, on the microstructure and mechanical properties of flux cored arc welded deposits have been investigated for the purpose of improving mechanical properties. Microstructure of weld metals was mainly influenced by manganese content, and manganese increased the volum fraction of acicular ferrite and refined the microstructure. Also, tensile properties were governed by manganese content, ultimate tensile strength and yield strength were increased by approximately 82MPa and 58MPa per 1% Mn addition to the deposit. Toughness was improved by increasing Mn content and lowering Si content. Optimal impact properties were obtained at above 1.8wt% Mn and below 0.5wt% Si. Acicular ferrite was predominant factor in improving mechanical properties. Formation of acicular ferrite was promoted by manganese and no direct relationship between AF(acicular ferrite) proportion and oxygen in weld metal was found.

  • PDF

사면보강재의 강우 및 온도에 의한 변형 해석 (Deformation Estimation of Slope Reinforced Materials by Rain and Temperature)

  • 홍성진;장기태;한희수
    • 지구물리
    • /
    • 제8권2호
    • /
    • pp.97-103
    • /
    • 2005
  • It is necessary, in the light of the importance of long-term slope stability problem, to develop a simple method or tool which can figure out the possible failure zone resulted from weathering effect and other factors. The FBG sensor system is used to estimate the correlations between the temperature and the slope in Yunhwajae, and to find a failure zone in slopes effectively. This research is to seek for the correlation between the soil temperature distribution and the strain distribution in a active zone by analyzing the data from the in-situ measurement so that the possible failure zone should be well defined based on the correlation. The zone of high temperature fluctuation can be regarded as one of the possible sliding zone due to the weathering effect while the constant temperature depth of the ground, if exists, would not be relatively affected by the weathering process.

  • PDF

사면의 변이영역에서 보강재의 변형률 특성 (Strain Characteristics of Reinforcing materials in the transition zone of slopes)

  • 김경태;장대수;장기태;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

네일로 보강된 구조물에서의 변이영역과 변형률 분포 (Strain Distribution of transition zone in a nailed wall)

  • 장기태;남궁한;유병선;김경태;권병근;이선경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 사면안정 학술발표회
    • /
    • pp.235-239
    • /
    • 2000
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

네일로 보강된 구조물에서의 변이영역과 변형률 분포 (Strain Distribution of Transition Zone in a Nail Wall)

  • 장기태;남궁한;유병선
    • 지구물리
    • /
    • 제8권1호
    • /
    • pp.39-43
    • /
    • 2005
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain istribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

선회연소기를 이용한 산소부화연소화염의 연소 특성 연구 (Characteristics of Oxygen-Enhanced Flame in Swirl Burner)

  • 이윤원;안국영;김한석;이창언
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.149-154
    • /
    • 2001
  • The emission characteristics, flame stability, the composition of the flame zone and temperature profile were studied experimentally. The compositions of oxydant were varied by substituting $N_2$ with $CO_2$ at the constant $O_2$ concentration. Results showed that flame became unstable due to the high heat capacity, low transport rate and strong radiation effect of $CO_2$ in comparison with those of $N_2$. The reaction zone was cooled, broadened, as the conversion ratio of $CO_2$ to $N_2$ was increased. Temperature has a large effect on the NOx emission. The concentration of NOx in flue gas decreased due to the decreased temperature of reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the conversion ratio of $CO_2$ to $N_2$ was increased, the emission of CO and the higher temperature zone increased due to the decrease of reaction rate by the cooling effect.

  • PDF