• 제목/요약/키워드: effect of column length

검색결과 147건 처리시간 0.021초

Parametric studies on smoothed particle hydrodynamic simulations for accurate estimation of open surface flow force

  • Lee, Sangmin;Hong, Jung-Wuk
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.85-101
    • /
    • 2020
  • The optimal parameters for the fluid-structure interaction analysis using the Smoothed Particle Hydrodynamics (SPH) for fluids and finite elements for structures, respectively, are explored, and the effectiveness of the simulations with those parameters is validated by solving several open surface fluid problems. For the optimization of the Equation of State (EOS) and the simulation parameters such as the time step, initial particle spacing, and smoothing length factor, a dam-break problem and deflection of an elastic plate is selected, and the least squares analysis is performed on the simulation results. With the optimal values of the pivotal parameters, the accuracy of the simulation is validated by calculating the exerted force on a moving solid column in the open surface fluid. Overall, the SPH-FEM coupled simulation is very effective to calculate the fluid-structure interaction. However, the relevant parameters should be carefully selected to obtain accurate results.

소규모 철골조 노출형 주각부의 반복가력 실험 (Cyclic Loading Test for Exposed Column-base Plate Connections of Small-size Steel Structures)

  • 임우영;유영찬;유미나
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.34-45
    • /
    • 2017
  • 본 연구에서는 소규모 철골조에 대한 기존 건축물의 접합부 현황조사와 분석을 통해 노출형 주각부에 대한 내진성능을 평가하였다. 총 9개의 주각부에 대한 반복가력 실험을 통해 휨강도, 변형능력, 그리고 초기강성 등이 조사되었다. 실험의 주요 변수는 베이스 플레이트의 두께, 앵커볼트의 개수와 매립깊이, 앵커볼트 후크의 유무, 그리고 리브 플레이트의 유무이다. 본 실험결과에 의하면, 주각부의 휨거동은 앵커볼트의 개수와 매립깊이, 그리고 베이스 플레이트의 두께에 영향을 받는 것으로 나타났다. 반면에, 주각부에 설치된 리브플레이트는 휨강도에 큰 영향을 주지 않는 것으로 나타났다. 종합적으로 노출형 철골 주각부와 기초부 그리고 앵커볼트 등이 모두 현행 구조기준을 만족한다고 할지라도, 앵커볼트와 기초부 콘크리트 사이의 부착력이 충분하지 않을 경우, 슬립형 거동이 관측되어 개선이 필요한 것으로 파악되었다. 앵커볼트의 매립깊이가 현행 구조기준을 만족하고, 앵커볼트에 후크가 설치된 경우, 노출형 주각부의 초기강성은 주각부가 구속되었을 때의 휨강성 하한값의 약 15% 수준인 것으로 나타났다.

Plastic hinge length for coupled and hybrid-coupled shear walls

  • Abouzar Jafari;Meysam Beheshti;Amir Ali Shahmansouri;Habib Akbarzadeh Bengar
    • Steel and Composite Structures
    • /
    • 제48권4호
    • /
    • pp.367-383
    • /
    • 2023
  • A coupled wall consists of two or more reinforced concrete (RC) shear walls (SWs) connected by RC coupling beams (CBs) or steel CBs (hybrid-coupled walls). To fill the gap in the literature on the plastic hinge length of coupled walls, including coupled and hybrid-coupled shear walls, a parametric study using experimentally validated numerical models was conducted considering the axial stress ratio (ASR) and coupling ratio (CR) as the study variables. A total of sixty numerical models, including both coupled and hybrid-coupled SWs, have been developed by varying the ASR and CR within the ranges of 0.027-0.25 and 0.2-0.5, respectively. A detailed analysis was conducted in order to estimate the ultimate drift, ultimate capacity, curvature profile, yielding height, and plastic hinge length of the models. Compared to hybrid-coupled SWs, coupled SWs possess a relatively higher capacity and curvature. Moreover, increasing the ASR changes the walls' behavior to a column-like member which decreases the walls' ultimate drift, ductility, curvature, and plastic hinge length. Increasing the CR of the coupled SWs increases the walls' capacity and the risk of abrupt shear failure but decreases the walls' ductility, ultimate drift and plastic hinge length. However, CR has a negligible effect on hybrid-coupled walls' ultimate drift and moment, curvature profile, yielding height and plastic hinge length. Lastly, using the obtained results two equations were derived as a function of CR and ASR for calculating the plastic hinge length of coupled and hybrid-coupled SWs.

윤활유와 베어링 볼을 내장한 원통형 구조물의 감쇠특성에 관한 실험적 연구 (Experimental study on the damping characteristics of a cylindrical structure containing oil and bearing balls)

  • 류봉조;송선호
    • 소음진동
    • /
    • 제6권1호
    • /
    • pp.107-114
    • /
    • 1996
  • 윤활유와 베어링 볼을 내장한 원통형 구조물이 외부로부터의 굽힘 하중을 받을 때의 진동감쇠 특성을 조사하였다. 심험대상인 원통형 구조물의 내부에는 윤활유의 점성력과 베어링 볼의 관성력에 의한 저항력이 발생하며 이 저항력에 의하여 원통형 구조물의 진동이 감쇠된다. 윤활유와 베어링 볼의 감쇠력이 최대가 되는 최적 혼합체를 찾기 위하여 점도가 다른 윤활유와 재질 및 직경이 다른 베어링 불을 알루미늄관에 넣고 감쇠력을 측정하였다. 실험 결과를 무차원 변수를 사용하여 분석하였으며 수평 원통과 수직 원통의 감쇠율을 비교하였다. 수령 원통의 경우에 감쇠율의 변화가 거의 없었으나 수직원통의 경우 원통 길이에 대한 베어링 볼 직경 의 비율이 약 0.28 이상부터 감쇠율이 증가하기 시작하였다. 볼의 직경과 원통 직경 비에 대한 감쇠율의 변화와 세장비 및 중력 효과에 대한 감쇠율의 영향도 조사하였다.

  • PDF

Base Plate로 보강된 기둥-기초 접합부의 뚫림전단강도 연구 (A Study on Punching Shear of Column-Foundation Joint Connection for Reinforced Steel Base Plate)

  • 김성겸;박종권;한상희;김병철;장일영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.1-9
    • /
    • 2015
  • 본 논문에서는 RC 기둥-기초 접합부분을 중공형 및 확장형 강재 Base Plate로 보강한 실험체에 대한 하중 재하 실험을 실시하여, 강재 Base Plate가 부착된 RC 기둥-기초에서의 뚫림전단에 대한 보강효과를 정량화 하기 위한 구조해석 및 기초적 실험 연구를 수행하였다. 실험은 각 실험체별 부착된 Base Plate의 두께, 내민길이, 치수, 형식 등의 변수에 따라 수행하였으며 실험을 통하여 응력분산에 적합한 적정 Base Plate의 모양 및 치수를 확인하였고, 보강효과에 대하여 분석하였다. 실험을 통해 Base Plate가 기초에 전해지는 수직하중의 응력분산에 효과적이었으며 폐쇄형보다 중공형 보강이 효율적인 것을 확인하였다. 보강을 통해 변위연성 능력의 향상으로 기존의 기초두께보다 두께가 감소한 실험체에서도 기존보다 높은 성능을 나타냈다. 보강 후의 실험체로부터 구조물의 거동특성을 취성으로부터 연성으로 유도 할 수 있었으며, 실험체를 파괴시까지 가력함으로써 파괴시 보강 전, 후에 대한 균열 및 파괴양상을 확인 하였다.

디젤로 오염된 토양에의 펜톤 산화공법 적용을 위한 산화제의 주입비 영향 연구 (Treatment of Diesel-Contaminated Soils by Fenton Oxidation)

  • 임명희;손영규;윤준기;김지형
    • 한국환경과학회지
    • /
    • 제17권2호
    • /
    • pp.203-210
    • /
    • 2008
  • The batch tests were performed to determine the ratio of Fenton reagent on diesel contaminated soil. The objective of a column test was to determine and optimize the hydrogen peroxide requirements for the remediation of a soil contaminated with diesel fuel. The batch test were done on 5 g diesel contaminated soil containing hydrogen peroxide (35%) and Iron (II) sulfate. The $H_2O_2(g):Fe^{2+}(g)$ ratio varied 1:0, 30:1, 15:1, 5:1, 1:1, with contact reaction time 120min. Initial diesel concentration were 2,000 mg/kg, 5,000 mg/kg, and 10,000 mg/kg. Average diesel removal from the contaminated soil is 97% after 2hrs. Results of this study showed possible application of without addition of iron source. In column test, treatment of a diesel-contaminated soil (initial diesel concentration: 2,000 mg/kg, 5,000 mg/kg, and 10,000 mg/kg) with hydrogen peroxide (35%) only was containing natural-occurring minerals. The time required for the column test was approximately 90min, 180min, 270min; column length was 5 em, 10 em, and 15 em. The most effective stoichiometry (final diesel cone.: $200{\sim}300mg/kg$) of 0.2 g peroxide consumed/mg diesel degraded. Further investigation is required to identify the effect of soil organic matter and soil mineral.

Bond-slip behaviour of H-shaped steel embedded in UHPFRC

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Chen, Chufa;Li, Yongjie;Lin, Zhiwei;Liao, Wen-I
    • Steel and Composite Structures
    • /
    • 제38권5호
    • /
    • pp.563-582
    • /
    • 2021
  • The present study experimentally and analytically investigated the push-out behaviour of H-shaped steel section embedded in ultrahigh-performance fibre-reinforced concrete (UHPFRC). The effect of significant parameters such as the concrete types, fibre content, embedded steel length, transverse reinforcement ratio and concrete cover on the bond stress, development of bond stress along the embedded length and failure mechanism has been reported. The test results show that the bond slip behaviour of steel-UHPFRC is different from the bond slip behaviour of steel-normal concrete and steel-high strength concrete. The bond-slip curves of steel-normal concrete and steel-high strength concrete exhibit brittle behaviour, and the bond strength decreases rapidly after reaching the peak load, with a residual bond strength of approximately one-half of the peak bond strength. The bond-slip curves of steel-UHPFRC show an obvious ductility, which exhibits a unique displacement pseudoplastic effect. The residual bond strength can still reach from 80% to 90% of the peak bond strength. Compared to steel-normal concrete, the transverse confinement of stirrups has a limited effect on the bond strength in the steel-UHPFRC substrate, but a higher stirrup ratio can improve cracking resistance. The experimental campaign quantifies the local bond stress development and finds that the strain distribution in steel follows an exponential rule along the steel embedded length. Based on the theory of mean bond and local bond stress, the present study proposes empirical approaches to predict the ultimate and residual bond resistance with satisfactory precision. The research findings serve to explain the interface bond mechanism between UHPFRC and steel, which is significant for the design of steel-UHPFRC composite structures and verify the feasibility of eliminating longitudinal rebars and stirrups by using UHPFRC in composite columns.

주철근 겹침이음된 휨-전단 RC교각의 실물모형 준정적 실험 (Quasi Static Test of Lap Spliced Shear-Flexure RC Piers Using Real Scale Models)

  • 곽임종;조창백;조정래;김영진;김병석
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.203-210
    • /
    • 2002
  • The past bridge design specifications of Korea didn't include 1imitation on the amount of lap splices in the plastic hinge zone of piers, and so do current specifications. But these specifications include just limitation on the minimal length of lap splices. Thus, a large majority of non-seismically designed bridge piers may have lap splices in plastic hinge zone. In this study, model pier was selected among existent bridge piers whose failure mode is complex shear-flexure mode. Full scaled RC pier models whose aspect ratio is about 2.67 were constructed and quasi static test according to the drift level history was implemented. From the test results, effect of the lap splices on the seismic performance of bridges piers was analyzed, and the seismic capacity of the model bridges was evaluated by capacity spectrum method.

  • PDF

플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과 (The Effect of Anchorage with Shear Reinforcement in Flat Plate System)

  • 최창식;배백일;최윤철;최현기
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.667-675
    • /
    • 2012
  • 플랫 플레이트는 실의 배치가 지속적으로 바뀌는 오피스와 같이 유연한 공간의 배치를 위해 그 사용처가 증가하고 있다. 플랫 플레이트 구조를 사용함에 있어서 실무에서의 주요 문제는 슬래브-기둥 접합부에서 발생는 뚫림 전단 파괴에 대한 적절한 보강을 해주는 것이다. 이 연구에서는 플랫 플레이트 구조의 내부 슬래브-기둥 접합부에 대한 실험을 수행하였다. 세 가지의 특수한 전단 보강근이 구조물 전체의 파괴를 유발시킬 수 있는 플랫 플레이트 슬래브-기둥 접합부의 취성적인 뚫림 전단파괴를 방지하기 위해 제안되었다. 총 네 가지의 프랫 플레이트 실험체가 수직 방향의 단조 가력에 의해 수행되었다. 전단 보강근은 뚫림 전단강도를 높여주는 역할과 취성파괴를 방지하는 역할을 해 주었다. 수행된 실험에서 전단보강근이 충분한 정착길이를 확보하지 못하여 전단보강근의 항복 이전에 파괴가 일어났다. 실험 결과를 통한 FE 모델의 검증이 이루어졌으며 검증된 FE 모델을 통해 전단보강근의 부착 성능에 대한 변수 분석이 수행되었다. 주요 변수는 슬래브의 두께, 콘크리트의 압축강도였으며 전단보강근의 성능을 산정할 수 있는 방법을 제시하였다.

Control of buildings using single and multiple tuned liquid column dampers

  • Chang, C.C.;Hsu, C.T.;Swei, S.M.
    • Structural Engineering and Mechanics
    • /
    • 제6권1호
    • /
    • pp.77-93
    • /
    • 1998
  • Some design formulas and design procedures for single and multiple tuned liquid column dampers (TLCDs) are proposed in this study. Previous studies show that if the properties of the TLCD system are properly selected then the TLCD could be as effective as the traditional tuned mass dampers. In addition, the TLCD system offers advantages such as flexibility in terms of installation, little maintenance required, and potentials for multiple usage, etc., which are incomparable by other mechanical types of dampers. In this paper, a set of optimal properties such as length and head loss of a TLCD system are derived under the assumption that the building vibrates in a dominate mode and is subjected to Gaussian white noise excitation. A design procedure for a single TLCD system will be illustrated and discussed. Due to the nonlinearity in the damping term, the TLCD system is sensitive to the loading intensity. This loading sensitivity could limit the application range of the TLCD system. It will be shown in this paper that such a nonlinear effect can be reduced by using multiple TLCDs. As a demonstrative example, the control effects on a flexible building modeled as a single degree-of-freedom system subjected to white noise excitation will be analyzed and discussed using single or multiple TLCDs.