• Title/Summary/Keyword: economical evaluation

Search Result 606, Processing Time 0.033 seconds

The preliminary evaluation of semi-quantitative analysis by in situ pre-chromatographic derivatization of amines and image analysis in TLC (TLC상 분리 전 직접적 유도체화 반응과 이미지 분석을 통한 아민 화합물의 반정량분석을 위한 선행평가)

  • Kim, Younsu;Choi, Sung-Woon
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.79-85
    • /
    • 2015
  • A preliminary experiment was performed to develop a fast, convenient, and economical semi-quantitative method of analyzing amphetamine-like amines from images of derivatives. These were generated from the reaction (in situ, co-spot) of three amphetamine-like compounds with three derivatization reagents on a TLC plate. The attempt was made to optimize the reaction conditions for an efficient derivatization reaction, and TLC images taken by a digital camera were analyzed using two types of image analysis program (CP Atlas 2.0 and ImageJ) for repeatability (RSD, %) and linearity (R2). Then, their results were compared. For efficient derivatization, the reaction conditions needed to be modified. The results of image analysis of each of the samples at two different concentrations (0.5 mg/mL and 0.01 mg/mL) showed that the RSD values for reaction repeatability were in the range of 0.69-5.50%. From the calibration curves between the area of the derivative and the concentration of amines, the R2 values (R2 > 0.9906) for good linear correlation were found to be high, in a concentration range of 0.1-0.005 mg/mL of amines. In addition, the two programs demonstrated little difference in the analysis of repeatability and linearity of the derivatization, so that the current method has the potential to be used for the semi-quantitative analysis of amines.

Field Applicability Evaluation of Foundation Combine with Footing and Pile by Model Test (모형실험을 통한 복합기초의 현장 적용성 평가)

  • Kim, Hak-Moon;Jang, Kyung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3729-3744
    • /
    • 2011
  • As the size of structures become larger by civil and architectural structures becoming large, deeply underground, and high-rise, the conditions of underground foundation vary according to the location that the lack of bearing capacity locally because of ununiform of foundation in some parts is frequent. Generally, when the foundation is not homogeneous, the acquisition of safety through applying the most conservative foundation method possible becomes the focus to secure the stability of the superstructures. It is considered as because of inability to verify the application and stability and application of construction of different foundations through an outlined review because of lack of study in case of different foundation of mixed use of direct foundation and pile foundation. Therefore, through measurement interpretation of the different foundation in which the direct foundation and pile foundation are mixed in use, the grounds in which the hypothetical bearing capacity changes dramatically was modeled to evaluate the applicability of different foundations. Also, based on the results of measurement interpretation, various foundations are created by using plaster, Joomunjin standard soil, and rubble to conduct an indoor model test to compare and analyze the movement of pile foundation and different foundations. Based on such research results, the stability and applicability of the different foundations which is more efficient and economical than the existing foundations in case of grounds in which the bearing capacity changes dramatically by comparing and analyzing the different foundations (direct foundation + pile foundation) with the conservative pile foundation and mat foundation. As a result, when the different foundation is applied, the overall settlement amount increased than the conservative pile foundation. However, the difference was very minute and it has been confirmed to be no issue as a result of assessment of stability of the differential settlement of structures through critical angle displacement.

High Utilization of Photovoltaic Power System in Rural Green Village Location Analysis and Evaluation using GIS - With Chubumyeon, Keumsan, Chungnam province - (GIS를 이용한 태양광 발전시스템의 활용도 높은 농촌 그린빌리지 적정입지 평가 - 충청남도 금산군 추부면을 중심으로 -)

  • Doh, Jae-Heung;Kim, Dae-Sik;Koo, Hee-Dong
    • Journal of Korean Society of Rural Planning
    • /
    • v.20 no.1
    • /
    • pp.51-62
    • /
    • 2014
  • The composition of rural Green Village requires higher utilization of renewable energy in those selected rural villages. The purpose of this study is to select the best results of rural green villages when using photovoltaic power system(PV system). 10 different rural villages in Chubumyeon, Keumsan, Chungnam province, were selected as study villages. This study shows measured solar radiation data, a 20-year time series data, and GIS spatial analysis; and whose were used to predict the photovoltaic power generation. PV system is used as a form with capacity of 3kWp to use for personal and public houses. Generation data was calculated by the town, where the economics of the Green Village location analysis was performed; and the solar radiation's correction factor was calculated by the 20-year time series data and measured data by study villages. By applying to the data of DEM, slope and aspect of the study villages were found, therefore performed. Spatial analysis tools were performed by using solar radiation map's tools. Those data found were used to calculate the average needed energy every months. When used the properly calculated data, towns performed economical energy consumption in rural Green Village. Every study villages have showed very high potential for PV system. Sungdangri ranked at the first (7,401kWp/year), Jangdaeri follows behind to the second (7,203kWp/year) and Yogwangri at third (7,89kWp/year) which shows higher developed energy than other study villages. The areas covered of these three towns are as follows: Sungdangri at $33,300m^2$, Jangdaeri covers $18,000m^2$ and Yogwangri shows $46,800m^2$. With these results, analyzing the potentials using GIS spatial analysis before installation of PV system was possible. Also different villages and topography in study villages have showed various results by the area. For convenience and to shorten research time, it is possible and enough to use solar radiation tools when studying spatial analysis of solar radiation.

Application of KOMSAT-2 Imageries for Change Detection of Land use and Land Cover in the West Coasts of the Korean Peninsula (서해연안 토지이용 및 토지피복 변화탐지를 위한 KOMPSAT-2 영상의 활용)

  • Sunwoo, Wooyeon;Kim, Daeun;Kang, Seokkoo;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.141-153
    • /
    • 2016
  • Reliable assessment of Land Use and Land Cover (LULC) changes greatly improves many practical issues in hydrography, socio-geographical research such as the observation of erosion and accretion, coastal monitoring, ecological effects evaluation. Remote sensing imageries can offer the outstanding capability to monitor nature and extent of land and associated changes over time. Nowadays accurate analysis using remote sensing imageries with high spatio-temporal resolution is required for environmental monitoring. This study develops a methodology of mapping and change detection in LULC by using classified Korea Multi-Purpose Satellite-2 (KOMPSAT-2) multispectral imageries at Jeonbuk and Jeonnam provinces including protected tidal flats located in the west coasts of Korean peninsula from 2008 to 2015. The LULC maps generated from unsupervised classification were analyzed and evaluated by post-classification change detection methods. The LULC assessment in Jeonbuk and Jeonnam areas had not showed significant changes over time although developed area was gradually increased only by 1.97% and 4.34% at both areas respectively. Overall, the results of this study quantify the land cover change patterns through pixel based analysis which demonstrate the potential of multispectral KOMPSAT-2 images to provide effective and economical LULC maps in the coastal zone over time. This LULC information would be of great interest to the environmental and policy mangers for the better coastal management and political decisions.

Ductility Evaluation of Circular Hollow Reinforced Concrete Columns with Internal Steel Tube (강관 보강 중공 R.C 기둥의 연성 평가 해석)

  • Han, Seung Ryong;Lim, Nam Hyoung;Kang, Young Jong;Lee, Gyu Sei
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • In locations where the cost of concrete is relatively high or in situations where the weight of concrete members has to be kept to a minimum, it may be more economical to use hollow reinforced concrete vertic al members. Hollow reinforced concrete colun-ms with a low axial load, a moderate longitudinal steel percentage and a reasonably thick wall were found to perform in a ductile manner at the flexural strength, similar to solid columns. Hollow reinforced concrete columns with a high axial load, a high longitudinal steel percentage, and a thin wall were found, however, to behave in a brittle manner at the flexural strength, since the neutral axis is forced to occur away from the inside face of the tube towards the section centroid and, as a result, crushing of concrete occurs near the unconfined inside face of the section. If, however, a steel tube is placed near the inside face of a circular hollow column, the column can be expected not to fail in a brittle manner through the disintegration of the concrete in the compression zone. A design recommendation and example through the moment-curvature analysis program for curvature ductility are herein presented. A theoretical moment-curvature analysis for reinforced concrete columns, indicating the available flexural strength and ductility, can be conducted, providing that the stress-strain relation for the concrete and steel are known. In this paper, a unified stress-stain model for confined concrete by Mander is developed foi members with circular sections.

Design and performance evaluation of fish-luring system using the air-cooled LED lamp for jigging and angling boat (채낚기 어선용 공랭식 LED 집어시스템의 설계 및 성능평가)

  • Bae, Bong-Seong;Park, Byoung-Jae;Jeong, Eui-Cheol;Yang, Yong-Su;Park, Hae-Hoon;Chun, Young-Yull;Chang, Dae-Soo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • The fishing lamp is a fishing gear that gathers fish at night. But the cost of oil, which is used to light fishing lamp, has been risen significantly up to 30-40% of total fishing costs. Therefore it is very urgent to develop an energy economical fishing lamp in order to solve the business difficulties of fisheries. Under this background, this research aims at developing a fishing lamp for squid jigging and hairtail angling fishery using the LED, which has excellent energy efficiency and durability. The LED fishing lamp developed can be controlled to fix a fit direction of fish shoal deep because a fishing lamp can be adjustable up and down directions. One unit of fishing lamp has about an 80Watt capacity and the frame of fishing lamp is made of aluminium to emit generated heat of LED to outside. The LED lamp developed was highly durable, only 5.7% of emitting efficiency decreased for 18 months. The illuminance of a unit LED lamp was 2,070lux at 1m and 21lux at 10 m distance, and the intensity of LED lamp system emitted 2,580lux and 400lux at the respective distances. After development of this fishing lamp, 100 units are installed on operating fishing vessels. Experimental results show that energy consumption of squid jigging and hairtail angling was reduced by 40% and 87%, respectively. In conclusion, our methods showed elevated fishing power, compared with traditional fishing method: 37.7% for squid jigging and 24.5% for hairtail angling.

The Estimation of Patient's Waiting-Time Using Parking Time (주차시간을 이용한 외래환자 대기시간 추정)

  • Song, Jung-Hup
    • Quality Improvement in Health Care
    • /
    • v.2 no.2
    • /
    • pp.20-30
    • /
    • 1996
  • Background : Theoretically as the waiting-time of patient is estimated in queueing, many men and much money are needed. But being the estimation of patient s waiting-time very important in hospital service, so the continuous monitoring of waiting-time is inevitable. To verify that the estimation of waiting-time using parking time is economical, effective and continuous monitoring method and to develop utilizing the method, this study was done. Method : In parking confirmation office, the personnel of parking office wrote parking confirm time, chart number and whether medical examination and treatment finish or not in parking ticket. The next day the parking tickets were gathered and the above data were input. The input parking data were connected with the hospital outpatient file indexing chart number. Then the patient' s data for department, new patient or not, reservation or not, receipt time and payment time were retrieved. The group for finishing medical treatment were compared with that for not finishing in average time lag between confirmation and out-time for hospital. And In-time for hospital, receipt time, payment and out-time for hospital were also analyzed. Result : Confirming parking ticket, the group for finished medical treatment left hospital after 7 minutes. This result showed that the patient for finished medical treatment left hospital immediately. So parking time was reasonable to estimation of hospital-time was concluded. The time for medical treatment, diagnosis and test was constant for all patients and short for waiting time, Then I concluded that the parking time was reasonable for estimation patient's waiting time. Overall patient's waiting time was 113 minutes and new patient's time was 149 minutes, old patient's times was 109 minutes. Waiting time for reservation patient was 98 minutes and for non reservation patient was 122 minutes. The time from hospital arrival to payment was 50 minutes for the group of reservation patient and 69 minutes for non-reservation group. The time from payment to hospital leaving was 51 minutes and 56 minutes for non reservation group. The short time difference between reserved group and not reserved group from payment to hospital leaving time was due to bottle neck effect. Conclusion : The estimation of patient's waiting time using parking time was reasonable because the possession of car was common and the time for medical treatment was equal and the patient after treatment left hospital immediately. Using this method, timely, fast evaluation and continuous monitoring of the intervention effect were possible.

  • PDF

The Change of perception according to the fidelity of simulation in Objective Structured Clinical Examination for Procedural Skill of 4th Medical Students (의전원 4학년 학생의 과정기술 객관구조화진료시험에 도입된 시뮬레이션의 충실도에 따른 인식 변화)

  • Son, Hee-Jeong;Kim, Jin-Uk;Yi, Yu-Ri;Hwang, Byeong-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1178-1185
    • /
    • 2012
  • The 4th year medical students were randomly divided and designated as group HF and LF, representing high and low fidelity simulations respectfully. Both groups performed OSCE on 2 topics(adult intubation and IV cannulation) with each composed of the same scenario. Each scenario was developed by a faculty in charge of clinical skill education with supervision from 2 other faculty members. High fidelity simulations were designed as in-situ simulations in real OR. Low fidelity simulations had the same scenarios but the environment was simulated only with a simple task trainer in the classroom. All students participated in series of survey using a Likert scale before and after the simulations. The provided data was anlayzed with paired T-test and Mann-Whiteney test(p<0.05). The post simulations self evaluation score for group HF was lower than pre-simulation self confidence score for both topics of adult intubation and IV cannulation where as for group LF, it was lower only for adult intubation(p<0.05). In group HF, the needs for clinical training on both topics increased after the simulation. In group LF, there was no significant change of needs for clinical training between pre and post simulation survey. This suggest that fidelity may be a helpful factor to improve the motivation of the students and further study on economical aspect should be addressed.

A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel (대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.225-234
    • /
    • 2018
  • Domestic urban areas are experiencing serious traffic congestion problems due to continuous population growth and increased traffic volume. In order to solve the problem of traffic congestion, the study of great depth underground double deck tunnels using underground space is being actively carried out in the urban areas. The characteristics of great depth underground double deck tunnels are low in cross section, so the spread of fire smoke is expected to spread faster than the road tunnel in case of fire. Therefore, it is necessary to provide a fire smoke delay device which delays the spread of fire smoke when a fire occurs in a tunnels. In the previous study, the diffusion effect was analyzed according to the blocking area when the fire smoke spread delay device was operated through the 3D CFD in the study of preventing the smoke spread in the case of the tunnel fire. A study on fire smoke diffusion delay device using spring elasticity which is excellent in applicability to a tunnel and economical value is studied. In this study, fire smoke spread delay system was developed to fire smoke delay was experimentally analyzed. Fire smoke delay effect of fire smoke delay device appeared. Therefore, it is considered that the can minimize the damage of the victims when installed in the great depth underground double deck tunnels.

A Vibration Evaluation and Improvement Scheme for Open Test Blasting (노천시험발파의 진동평가와 개선방안)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.310-315
    • /
    • 2017
  • Although studies evaluating the effects of the blasting vibration on the adjacent structures from various angles have continued, cases of securing the safety of the adjacent buildings and researching the proper blasting method for the field condition by analyzing the vibration waveform of the measuring field while performing the open pit blasting are poor. Therefore, it is necessary to present a remedy for blasting pattern selection through test blasting that is appropriate for field conditions, and is economical and efficient. In this study, open pit blasting work was conducted based on the separation distance applied according to the standard blasting method by test blasting and the vibration regulation standard in the road expansion construction site to measure the blasting vibration value, and the vibration prediction equation by blasting methods was examined using a regression analysis computer program to calculate K, N, and R of the confidence level 95%. By setting the blasting allowed vibration standard of the test blasting target area to 0.3cm/sec, and the charring weight and blasting method by the separation distances according to the blasting vibration estimation equation of the open pit blasting guideline and the blasting vibration estimation equation of the test blasting were compared/analyzed, it was possible to identify the factors that increased the working expenses. In addition, the measurement and analysis of the adjacent structures during open pit blasting and the blasting vibration were performed after selecting the most adjacent structure to the open pit blasting spot to analyze the problems on the test blasting procedure and analysis method in the open pit blasting design/construction guidelines, which appeared in the process of completing open pit blasting construction, and a remedy is presented.