• Title/Summary/Keyword: ecological apartment

Search Result 269, Processing Time 0.021 seconds

A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment (확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

The Method of Quantitative Analysis Based on Big Data Analysis for Explanatory Variables Containing Uncertainty of Energy Consumption in Residential Buildings - Focused on Apartment in Seoul Korea (주거용 건물의 에너지 실사용량의 불확실성을 내포한 설명변수 인자에 대한 빅데이터 분석 기반의 정량화 방법 - 서울지역의 공동주택을 중심으로)

  • Choi, Jun-Woo;Ahn, Seung-Ho;Park, Byung-Hee;Ko, Jung-Lim;Shin, Jee-Woong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: The energy consumption of apartment units is affected by the lifestyle of the residents rather than system technology. In this study the numerical analysis of assumed energy consumption correlation factors with arbitrary value due to uncertainty. It is intended to be used as a simulation correction value which can be utilized as a predicted value of actual energy usage. The correction value of the simulation is set in the developed form of the existing process that derives the actual usage amount. The simulation results used in the existing evaluation system are used to maintain the useful value as the current system evaluation scale and predict the actual capacity. Method: The method of the study is to statistically analyze the data frames of all complexes capable of collecting the annual energy usage and to reconstruct the population by adding the variables that are expected to be correlated. Repeat the data frame configuration with variables that are assumed to be highly correlated with energy use levels. Determine whether there is correlation or not. The intensity of the external characteristics of the building equipment related to the energy consumption is presented as the quantitative value. Result: The correlation between electricity consumption and trading price since 2010 is analyzed as (Correlation coefficient 0.82). These results are higher than (Correlation coefficient 0.79), which is the correlation between residential area and trading price. This paper signifies the starting point of the methodology that broadens the field of view of verification of simulation feasibility limited to the prediction technique focused on the simulation tool and the element technology scope.The diversified phenomenon reproduction method develops the existing energy simulation method.It can be completed with a simulation methodology that can infer actual energy consumption.

Operation of Community Resident Groups in a Community-Based Participatory Health Promotion Program for Low-income Older Adults (저소득층 노인의 건강증진을 위한 지역사회 참여형 연구에서 지역사회 주민 조직의 구성과 운영)

  • Yoo, Seung-Hyun;Butler, James;Elias, Thistle I.
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.5
    • /
    • pp.15-26
    • /
    • 2009
  • Objectives: This paper is intended to illustrate and to discuss the organization and functioning of community resident groups (CRGs) in a community-based participatory health promotion program for healthy aging. Methods: CRGs were convened in 12 government-subsidized apartment communities for low-income seniors in Pennsylvania, U.S.A., to promote healthy aging. Researchers facilitated CRG meetings following a 6-step process of community empowerment and utilizing a social ecological model for assessment and planning. Almost 200 project-related documents were qualitatively analyzed using matrix analysis principles such as cross-classification of multiple dimensions to identify patterns in the data and matrix building for displaying such patterns. Results: CRGs were venues at which apartment building residents could interact, discuss health priorities, and become change agents in their building. CRG members' community health priorities were about their daily living, including building conditions, poor access to fresh food, and unhealthy resident relations. Specific patterns arose in analysis indicating that leadership withing the CRGs, consistency of meetings and participants' attendance, and ability to link health concerns to daily experience impacted the CRGs' capability to identify and accomplish their goals. Conclusion: Community health issues and solutions to those issues identified by CRGs were unique to community contexts and interests. Consistent participation by community members, a consistent pattern of group activities such as monthly meetings, and having established leadership to manage CRG activities were prominent characteristics of community group functioning.

Analysis of Environmental Equity of Green Space Services in Seoul - The Case of Jung-gu, Seongdong-gu and Dongdaemun-gu - (서울지역 녹지서비스의 환경형평성 분석 - 중구, 성동구, 동대문구를 사례로 -)

  • Ko, Young Joo;Cho, Ki-Hwan;Kim, Woo-Chan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.2
    • /
    • pp.100-116
    • /
    • 2019
  • Urban green spaces, as a means to mitigate social problems and environmental risks, are getting more attention in evaluating urban environment. The inequity of green space distribution is becoming a major issue in urban planning and management. This study investigated the characteristics of green space in 3 districts (Jung-gu, Dongdaemun-gu, Seongdong-gu), that are composed of 46 administrative divisions in central Seoul, to analyze the environmental equity of urban green spaces. The correlations between the amount of green space, including the coverage of street trees, and the socioeconomic status of each administrative division were analyzed. To deduce the effects of plant coverage on the urban temperature regime, the relationship between the normalized difference of vegetation index (NDVI) and land surface temperature (LST) was analyzed. The research revealed that the mean NDVI of an administrative division was negatively correlated with the percentage of basic living recipients and disabled people. The LST of a division with low NDVI was higher due to the lack of green coverage. Such environmental inequities were closely related to residential building type, which was strongly affected by the economic status of residents. The LST of an apartment area was $2.0^{\circ}C$ lower than that of single-family houses and multi-housing areas. This is expected as the average NDVI of the apartment area was more than twice as high as the other environments considered in this study. The inequity can be exacerbated without urban planning which is deliberately designed to reduce it.

A Study on the Development of Sustainable Durability Design System for Reinforced Concrete Structure under Chloride Attack Environments (염해 환경하의 철근콘크리트 구조물의 친환경 내구설계 시스템 개발에 관한 연구)

  • Kim, Rak-Hyun;Roh, Seung-Jun;Tae, Sung-Ho
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.87-94
    • /
    • 2011
  • This study was suggested to develop sustainable durability design system and proposed the plan to evaluate design conditions that meet the intended service life and $LCCO_{2}$ reduction level of reinforced concrete structure easily from the early design stage. For that the W/B and covering depth of the concrete structure were calculated through calculation of service life based on standard specification expression and the quantitative reduction rate of the vertical member of reinforced concrete structure by the calculated W/B was applied. Life cycle of building classified into construction stage, operation stage, maintenance stage, and demolition/disposal stage and the method of $CO_{2}$ evaluation of each stage was proposed. For construction stage, the major construction materials that take up over 80% $CO_{2}$ emitting during building construction were selected and the $CO_{2}$ evaluation method for 5 standard apartment houses was proposed. Also, for operation stage, $CO_{2}$ emission was calculated through calculation of heating load by energy efficiency rating certification system. For maintenance stage, $CO_{2}$ emission was calculated using concept of re-construction by life and for demolition/disposal stage was calculated with the use of construction standard estimate. As a result of the case study by such evaluation methods, 80 years of service life and 17 specifications of sustainable durability design that meet the 40% intended $LCCO_{2}$ reduction level were deduced. The Maximum $LCCO_{2}$ reduction rate was analyzed by 47.2%.

The Characteristics of the Repair Cost Distribution in Apartment Housing

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: The repair would require to conserve and improve the building function and performance since built. Each household is responsible for maintaining the public facilities and paying the required cost. Therefore, it needs to get the tool or method to forecast the required cost in the future. Before the repair cost is provided, it needs to catch the repair cost distribution and provide the unit cost for the repair cycle. In this study, it aimed at providing the repair cost unit and analyzing the repair cost distribution in a roof proofing work, elevator work and building painting, which are divided into a fully work and partly change. Results of this study are shown that first, the average repair cost for roof proofing work is provided with $166.59{\times}10^3won/household$ and $1.59{\times}10^3won/m^2$ of a full change, $33.22{\times}10^3won/household$ and $0.33{\times}10^3won/m^2$ for a partly work. In addition, elevator work is $557.45{\times}10^3won/household$ and $5.38{\times}10^3won/m^2$ for a full change, $32.92{\times}10^3won/household$ and $0.56{\times}10^3won/m^2$ for a partly repair. Painting has a $304.48{\times}10^3won/household$ and $2.94{\times}10^3won/m^2$. Second, the distribution pattern of repair unit cost has a weibull-typed distribution which has a long tail to the right.

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses- (건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -)

  • Lee, Su-In;Kim, Jeong-Gook;Kim, Seo-Hun;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

A Schematic Estimation Development of the CO2 Emission in the Maintenance of Repair of Apartment Housing (개·보수 유지관리부문의 이산화탄소 배출량 간이 산정방법에 관한 연구)

  • Lee, KangHee;Ahn, YoungHan;Chae, ChangU
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.99-104
    • /
    • 2013
  • Many activities associated with the construction and habitation of buildings are connected with issues affecting the environment such as global warming, climate change, and consumption of valuable natural resources such as fossil fuels. To minimize negative impacts on the environment, the building industry worldwide has implemented green building practices in many countries. One of the main green strategies is to reduce greenhouse gas emissions caused by residential structures because they are most substantially connected with global warming and climate change. To determine the actual quantity of green house gas emissions caused by the construction and use of a building, it is important to analyze total greenhouse gas emissions over the life cycle of buildings including construction, operation & maintenance(O&M) and demolition stages. Many studies suggest methods to calculate greenhouse gas emissions at the construction stage, but the literature addressing greenhouse gas emissions at the O & M stage is limited. A year-long study was conducted utilizing the deterioration method to calculate greenhouse gas emissions at the O & M stage of building life for condominium types of buildings in South Korea. Through this research, it is possible to analyze greenhouse gas emissions of buildings at the O & M stage, the longest span of the life cycle, and eventually help to calculate total greenhouse gas emissions over the life cycle of the building.

Analysis of the Breakdown repair time of the Building Components in Public Rental-Housing Types (공공임대주택 유형별 부재의 사후보전 수선시기 설정연구)

  • Lee, KangHee;Ahn, YoungHan;Chae, ChangU
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.129-136
    • /
    • 2013
  • The rental housing has played a key role to supply a decent living space for the low-income households. The owner of the rental housing should maintain and manage the building physical condition. On the other hand, rents should use the housing without any damage and pay a certain fare for the rent. A rent is classified into two types : private and public. The public rent is mainly to supply a living space for non-available home owner with a low-rent fare. Many of public rent are built and supplied by the public institution or local government. The supplier would take a responsibility to maintain the building and components, reflected by the maintenance plan and repair scope. In this paper, it aimed at providing the repair time in building components of the public rental housing such as lighting, electrical cable, paintings and etc.. The repair time is analyzed with three calculation methods which are solved by the probability and empirical approach. Results are as follows : First, the repair time of the electrical facilities are maintained with 11yr, 10yr and 7 in permanent, public and redevelopment rent respectively. The roof proof has a repair time with 14yr, 11yr and 8 in permanent, public and redevelopment rent housing respectively. Second, Most of the components has a prior length of the repair time in permanent, public and redevelopment rent sequently. There is a difference in repair time according to the rental types. Therefore, it would continue to research the difference in aspect of the living style, building physics, living consciousness and etc.