• Title/Summary/Keyword: eco-efficiency

Search Result 627, Processing Time 0.026 seconds

Survey and Analysis of Power Energy Usage of University Buildings (대학건축물의 전력에너지 사용량 조사 및 분석)

  • Youn, Nam Sik;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.27-32
    • /
    • 2013
  • For the past seven years, the increase in the energy consumption of universities in Korea has been 3.7 times higher than the overall increase in the energy consumption across Korea (22.5%). This is an example that shows that universities have been a massive source of greenhouse gases. Such an increase has been attributed to the new and expanded construction of architectural structures on campus. Many people argue that the increasing number of buildings may cause waste of energy and loss of efficiency. Therefore, this study was conducted as a preliminary study to derive energy efficiency measures for new university buildings. The two aspects of energy-saving as required by the eco-friendly structure certification standards have been applied to analyze the use of new/renewable energy and the energy consumption of new university buildings that have applied light density and light engineering methods. Based on these results, the major sources of energy of existing buildings and new university buildings were compared to comparatively discuss how effectively they improve energy performance.

A Study on Development of Ubiquitous Bio-Sensors for Increasing Energy Efficiency (에너지 효용 증대를 위한 바이오 센서 개발에 관한 연구)

  • Han, Seung-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.58-63
    • /
    • 2008
  • It is essential to investigate the structure and the main characteristic of Home USN (Ubiquitous Sensor Network) technologies in built ubiquitous environment while designing bio-sensors. For this study, Thermistor elements and Thermopile black body have been selected to implement ubiquitous technologies for bio-sensors and wireless network such as WiBro has been used to transfer sensing data to the BSN (Bio-Sensor Network) gateway. It is certain that efficiency of ubiquitous space design is improved if main components of each specific sensor network are analyzed precisely in digital way and corresponding communication modules are prepared accordingly. Ubiquitous technology, in conclusion, has to be applied not only with systematical mechanism or electronic setting but in human-centered atmosphere as well, keeping with deep consideration for bio-housing service factors in eco-friendly surrounding.

A Study on the Flow Characteristics of Aircraft Wing Surface with Various Dimple Patterns (익형 표면의 딤플 형상변화에 따른 유동특성 연구)

  • Hong, Woo;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.54-59
    • /
    • 2012
  • In order to have the high efficiency of aircraft wing and to improve the energy efficiency in field of eco-friendly transportation, the performance characteristics of the aircraft wing were studied with the change of lift to drag ratio through the CFD analysis. The design process was focused on generating the high lift force and low drag force as the lift to drag ratio was increased. In this paper, various dimple patterns were numerically designed to investigate the flow characteristics. Hexagon-and circle-shaped dimples, dimple distance and position were changed as the artificial conditions. The numerical analyses were conducted by using the commercial code, ANSYS CFX. Numerical results dependent on the turbulence intensity and lift to drag ratio distribution were graphically depicted for various dimple patterns.

Analysis of Energy Performance and PMV Improvement by Application of Passive Factor for Office Building Renewal (오피스건물 리뉴얼시 패시브 요소적용에 따른 에너지성능 및 PMV 개선에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.55-64
    • /
    • 2014
  • This paper presents a case study to investigate the monthly calculation method of ISO 13790 applied for a office building. The energy performance analysis according to improvement of insulation and air permeability of windows in K office buildings is investigated by means of building energy efficiency rating tool ($ECO_2-OD$). The K building energy system is tested experimently by the measurement of PMV(predicted mean vote) for the control of indoor thermal environment and heat transmission coefficient of windows and interior walls respectively, before and after the example K office building is remodeled passively. Therefore, Internet based energy assessment program of energy efficiency rating of office building can be applied as a program for the annual energy requirement and for evaluation of energy savings from the experimental and simulation results.

A study on development of measuring index about railway electrification effectiveness (철도전철화 효과 계량지표 개발에 관한 연구)

  • Kim, Jae-Hee;Park, Yong-Gul;Yang, Keun-Yul;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1575-1580
    • /
    • 2006
  • High speed and large transfer capability of railroad has been an important issue in Korean since KTX opening at 2004. Improvement projects for railway electrification are progressed in the conventional line as well as high speed line because various operation plan is performed such as interaction between high speed line and conventional line and operation of tilting train etc. Especially, railway electrification has many advantages which are cost effective and eco-friendly. But it also has some problems such as construction costs and accidents due to electrification. Therefore this paper developed measuring index of electrification railway benefit. By comparing between diesel and electrical locomotive, the operations of before and after the electrification and measurements quantitative index such as energy efficiency, enlargement of transfer capability, environmental pollution and maintenance and efficiency of operation is presented. In the future, Overall benefit and cost of railway electrification will be analyzed.

  • PDF

High Performance Piezoelectric Transformers by PIM Using Nano-sized Powders

  • Yoon, Tae-Shik;Yoon, Man-Soon
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.32-33
    • /
    • 2006
  • Processing and properties of high power piezoelectric transformer (PT) fabricated by PIM with nano-sized piezoelectric powders are demonstrated. The high power characteristics of a PMed dome-shaped PT were examined by the lighting test for a 55watt PL lamp. The 55watt PL lamp was successfully driven by the PIMed PT with sustaining efficiency higher than 98%. The transformer with ring/dot area ratio of 2.1 exhibited the maximum properties in terms of output power, efficiency and temperature stability.

  • PDF

A Study on System Structure and GUI Implement for Secure ESS use (안전한 ESS 사용을 위한 System 구조와 GUI 구현에 관한 연구)

  • Kim, Wantae;Kim, Hyunsik;Park, Byungjoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.2
    • /
    • pp.11-17
    • /
    • 2019
  • As interest in the efficiency use of energy has been recently rising, studies have been performed in utilizing various types of eco-friendly green energy and natural energy. Especially there has been rapidly increase in the fields using ESS (Energy Storage System), which is the technology for storing the energy from nature. The application fields of ESS is continuously growing and expanding to various types of technologies. However, in recent years there have been continuing problems with the safety of ESS. And related researches are going on. In this paper, we has proposed a system structure to utilize more secure ESS and has monitored the system status of ESS in real time by using smart phone app. This paper has also proposed a new method to configure secure ESS by implementing GUI (Graphical User Interface) to control the system. And then explain experimental results to investigate the efficiency of the proposed ESS.

Recovery of Cobalt from Waste Cathode Active Material Using Organic Acid (폐 리튬이온 배터리 양극으로부터 유기산을 이용한 코발트 회수)

  • Moon, Ji-Hoon;Ahn, J.E.;Kim, Hyun-Jong;Sohn, S.H.;Lee, H.W.;Kim, H.S.
    • Applied Chemistry
    • /
    • v.16 no.1
    • /
    • pp.73-76
    • /
    • 2012
  • Due to the developments of communications equipment and electronic devices, lithium ion secondary battery usage is growing. Along with demand increasing, the amount of scrap has been steadily increasing. In this study, method of cobalt recovery using organic eco-friendly is proposed. Sulfuric acid, Malic acid, Citric acid at reflux device had good cobalt leaching efficiency. And Sulfuric acid, Malic acid at the autoclave increased cobalt leaching efficiency.

Analysis of Animal Usage of Eco-bridge and Ecoduct Using an Infrared CCTV at the Baekdudaegan Mountain Range, Korea (적외선 CCTV를 활용한 백두대간 육교형 생태통로와 터널형 생태통로의 동물이용현황 분석)

  • Cho, Hye-Jin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.177-181
    • /
    • 2016
  • In order to prevent the fragmentation of animal habitat due to road construction, the most widely applied solution is building animal passes worldwide. In Korea, animal passes were introduced in the early 2000s, and through trial and error, the national guidelines for them and their design standards were published in 2010. These were criticized by politicians because of their relative inefficiency considering their high construction cost and their lack of animal usage. This study investigated the extent to which animals used the facilities. For this study, two types of animal passes, eco-bridges and ecoducts, were considered and the test sites were chosen from the Baekdu Mountains. The animal usage data was captured using infra-red CCTV cameras. The results showed that various types of animals used eco-bridges and ecoducts. Interestingly various types of birds were captured by cameras and endangered animals were also in them. The season, weather, and their surrounded vegetation also had effects on their usages. The infrared CCTV allowed detailed captures of animals but the electricity shortage was one disadvantage. During the last decades, a number of eco-bridges were constructed throughout the country and now we need to focus on their monitoring and maintenance for their successful efficiency and application.

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.