• Title/Summary/Keyword: echo time

Search Result 453, Processing Time 0.025 seconds

Performance Analysis of Audio Data Hiding Method based on Phase Information with Various Window Length (주파수 변환의 길이에 따른 위상 기반 오디오 정보 은닉 기술의 음질 및 성능 분석)

  • Cho, Kiho;Kim, Nam Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.232-237
    • /
    • 2013
  • The role of the window length of time-frequency transformation is important for the audio data hiding methods utilizing phase information. In this paper, the experiments for our audio data hiding method were conducted in order to evaluate the audio quality and robustness against reverberant environment. The experimental results showed the tendency that the worse audio quality but better robustness were obtained when the lengthy window was applied. The important reason for quality degradation was pre-echo which flatters the percussive sound. The results also indicated that the wireless communication theory related to the length of time-frequency transform can be applied in the field of audio data hiding and acoustic data transmission.

Conversational Quality Measurement System for Mobile VoIP Speech Communication (모바일 VoIP 음성통신을 위한 대화음질 측정 시스템)

  • Cho, Jae-Man;Kim, Hyoung-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2011
  • In this paper, we propose a conversational quality measurement (CQM) system for providing the objective QoS of high quality mobile VoIP voice telecommunication. For measuring the conversational quality, the VoIP telecommunication system is implemented in two smart phones connected with VoIP. The VoIP telecommunication system consists of echo cancellation, noise reduction, speech encoding/decoding, packet generation with RTP (Real-Time Protocol), jitter buffer control and POS (Play-out Schedule) with LC (loss Concealment). The CQM system is connected to a microphone and a speaker of each smart phone. The voice signal of each speaker is recorded and used to measure CE (Conversational Efficiency), CS (Conversational Symmetry), PESQ (Perceptual Evaluation of Speech Quality) and CE-CS-PESQ correlation. We prove the CQM system by measuring CE, CS and PESQ under various SNR, delay and loss due to IP network environment.

3.5 mm Coaxial One Port Vector Network Analysis Using Time Domain Reflectometry (반사 펄스의 주파수 해석을 이용한 광대역 3.5 mm 동축형 단일 포트 벡터 회로망 분석법)

  • Lee, Dong-Joon;Kwon, Jae-Yong;So, Joon-Ho;Kang, No-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.967-975
    • /
    • 2012
  • This paper presents a method to measure reflection coefficients of microwave devices or antennas based on time domain analysis with sampling oscilloscopes. The reflection coefficients were extracted by the Fourier transformation of echo pulses from devices with respect to the 20 GHz incident pulse signals. The three-error terms, which are commonly used for the correction of a microwave network, were determined using a 3.5 mm calibration kit. In addition, a modified error-correction model associated with a directional coupler for reflection coefficient measurements is introduced. The results were compared with those of measured with a commercial vector network analyzer.

Dialectical Interpretation regarding the Concept of Preservation and Restoration - With a focus on Eugène-Emmanuel Viollet-le-Duc, John Ruskin, and Camillo Boito - (보존과 복원 개념의 변증법적 해석 - 비올레-르-?, 존 러스킨, 카밀로 보이토의 이론을 중심으로 -)

  • Kim, Tae-Hyung;Kim, Young-Jae
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.135-144
    • /
    • 2018
  • This paper deals with preservation and restoration as a universal approach to conserve architectural heritage. The questions on how to preserve or restore them have been always major issues for many old buildings. Reading changes in ways of the thinking to solve such matters in the past helps to grasp the fundamental concepts to conserve cultural heritage at this point in time. The method is an important stage that leads to change our current attitude. Both the ways of the thinking for preservation and restoration should be re-interpreted to preserve memory or to restore identity depending on the current situation, and even should no longer be understood as two opposite options. Therefore, this paper focuses on the epistemological notion and reveals the origin and premise of modern historical perception that has become disconnected from the past works. By taking the writings of $Eug{\grave{e}}ne$-Emmanuel Viollet le Duc, John Ruskin, and Camillo Boito into consideration, the thesis shows that their thought, in the common denominator of the time, is a kind of reflection of consciousness according to particular historical contexts and that their ideas echo three dialectical paradigms derived from past and present, memory and forgetfulness, and history and truth.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease (크론병에서 자기공명영상 장운동기록의 단일호흡 단발 고속 스핀 에코기법: 딥러닝 기반 재구성의 영향)

  • Eun Joo Park;Yedaun Lee;Joonsung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1309-1323
    • /
    • 2023
  • Purpose To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

Application of Very Short-Term Rainfall Forecasting to Urban Water Simulation using TREC Method (TREC기법을 이용한 초단기 레이더 강우예측의 도시유출 모의 적용)

  • Kim, Jong Pil;Yoon, Sun Kwon;Kim, Gwangseob;Moon, Young Il
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.409-423
    • /
    • 2015
  • In this study the very short-term rainfall forecasting and storm water forecasting using the weather radar data were implemented in an urban stream basin. As forecasting time increasing, the very short-term rainfall forecasting results show that the correlation coefficient was decreased and the root mean square error was increased and then the forecasting model accuracy was decreased. However, as a result of the correlation coefficient up to 60-minute forecasting time is maintained 0.5 or higher was obtained. As a result of storm water forecasting in an urban area, the reduction in peak flow and outflow volume with increasing forecasting time occurs, the peak time was analyzed that relatively matched. In the application of storm water forecasting by radar rainfall forecast, the errors has occurred that we determined some of the external factors. In the future, we believed to be necessary to perform that the continuous algorithm improvement such as simulation of rapid generation and disappearance phenomenon by precipitation echo, the improvement of extreme rainfall forecasting in urban areas, and the rainfall-runoff model parameter optimizations. The results of this study, not only urban stream basin, but also we obtained the observed data, and expand the real-time flood alarm system over the ungaged basins. In addition, it is possible to take advantage of development of as multi-sensor based very short-term rainfall forecasting technology.

A Comparative Analysis of Basal Body Temperature to Ultrasound, as a Method of Ovulation Detection in Induced Ovulatory Menstrual Cycles (배란유도주기에 따른 초음파검사와 기초체온표의 비교분석)

  • Choi, W.;Suh, B.H.;Lee, J.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.12 no.2
    • /
    • pp.25-37
    • /
    • 1985
  • Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maximal diameter of follicles and observing the morphologic changes within the ovary from follicle to corpus luteum. The results were as following; 1. The diameter of the follicle measured at the day before disappearance was 21.1 mm on an average (S.D.: 2.14). The average follicular growth for 4 days before ovulation was measured at a rate of 2.8 mm/day, and rapid growth of follicle was observed 3.1 mm/day at the day before. 2. The changes associated with rupture of the follicles were the followings, in order of frequency; decrease in size(94%), disappearance of follicles(64%), fluid in the Cul-de-Sac(26%) and increased internal echoes(16%). 3. Only 20 of 50 cycles, exhibited a BBT dip and correlated with the estimated time of ovulation by ultrasound in 2 of which cases(10%). BBT nadir, 30 of 50 cycles, correlated in 5(16.7%). The first day of hyperthermic plateau(FDHP) and BBT coverline was exhibited in all cycles, correlated in 41(82%) and 35(70%) cases. 4. The relationship between the diameter of dominant dominant follicle, measured by ultrasound, and the basal body temperature curve were as following. During cycles in which dip was observed on the BBT curve, the follicular diameter were 10.5${\pm}$2.12 mm on 4 days prior to the point (D-4), and 12.5${\pm}$2.12 mm (D-3), 15.5${\pm$2.12 mm (D-2), 17.0${\pm}$1.41 mm (D-1) and 21.5${\pm}$2.12 mm just prior to the dip (D-0). In the nadir; 9.6${\pm}$1.67 mm (N-4), 12.8${\pm}$1.79 mm (N-3), 16.2${\pm}$1.92 mm (N-2), 18.2${\pm}$2.17 mm (N-1) and 21.4${\pm}$2.61 mm (N-0). In the First day of Hyperthemic Plateau (FDHP); 9.8${\pm}$1.36 mm (F-4), 12.4${\pm}$1.41 mm (F-3),15.1${\pm}$1.57 mm (F-2), 18.1${\pm}$1.67 mm (F-1) and 21.2${\pm}$2.25 mm (F-0). In the BBT coverline endopint; 9.9${\pm}$.39 mm (C-4), 12.5 ${\pm}$1.44 mm (C-3), 15.2${\pm}$1.64 mm (C-2), 18.0 ${\pm}$1.69 mm (C-1), and 21.2${\pm}$2.31 mm (C-0). 5. The relationship between the ultrasonographic signs of ovulation and the basal body temperature curve were as following. The BBT dip correlated with the ovulation in 2 cases, which revealed decrease in follicular diameter (100%), fluid pattem in the Cul-de-Sac (1 case, 50%) and complete disappearance of follicle (1 case, 50%). In the nadir (5 cases); the ultrasonographic signs of ovulation were decrease in follicular diameter (5 cases, 100%), fluid pattern in the Cul-de-Sac (1 case, 20%) and complete disappearance of follicle (3 cases, 60%). In the First day of Hyperthermic Plateau (41 cases); decrease in follicular diameter (40 cases, 97.6%), fluid pattern in the Cul-de-Sac (11 cases, 26.8%), appearance of internal echo and thickening of the wall (6 cases, 14.6%) and com plete disappearance of follicle (28 cases, 68.3%). In the BBT coverline endpoint (35 cases); decrease in follicular diameter (33 cases, 94.3%), fluid pattern in the Cul-de Sac (9 cases, 25.7%), appearance of internal echo and thickening of the wall (5 cases 14.3%) and complete disappearance of follicle (20 cases, 57.1%).

  • PDF