• 제목/요약/키워드: echo pattern

검색결과 90건 처리시간 0.029초

어군의 음향학적 형태 및 분포특성과 어종식별에 관한 연구 1.한국 연근해 멸치어군의 형태 및 분포특성과 종식별 실험 (Study on the Acoustic Behaviour Pattern of Fish Shool and Species Identification 1. Shoal Behaviour pattern of anchovy (Engraulis japonicus) in Korean waters and Species Identification Test.)

  • 김장근
    • 수산해양기술연구
    • /
    • 제34권1호
    • /
    • pp.52-61
    • /
    • 1998
  • We studied behaviour pattern of anchovy (Engraulis japonicus) shoal by a method of shoal echo integration and tested species identification by a method of artificial neural network using the acoustic data collected in the East China Sea in March 1994 and in the southern coastal waters of the East Sea of Korea in March 1995. Between areas, frequency distribution of 10 shoal descriptors was different, which showed characteristics of shoal behaviour in size, bathymetric position and acoustic strength. The range and mean of shoal size distribution in length and height was wider and bigger in the southern coastal waters of the East Sea than in the East China Sea. Relative shoal size of China Sea. Fractal dimension of shoal was almost same in both areas. Mean volume reverbration index of shoal was 3 dB higher in the southern coastal waters of the East Sea than in the East China Sea. The depth layer of shoal distribution was related to bottom depth in the southern coastal waters of the East Sea, while it was between near surface and central layer in the East China Sea. Principal component analysis of shoal descriptors showed the correlation between shoal size and acoustic strength which was higher in the southern coastal waters of the East Sea, than in the East China Sea. Correlation was also found among the bathymetric positions of shoal to some degree higher in the southern coastal waters of the East Sea than in the East China Sea. The anchovy shoal of two areas was identified by artificial neural network. The contribution factor index (Cio) of the shoal descriptors between two areas were almost identical feature. The shoal volume reverberation index (Rv) was showed the highest contribution to the species identification, while shoal length and shoal height showed relatively high negative contribution to the species identification.

  • PDF

무증상 여성의 유방초음파에서 발견된 군집 미세낭종 (Clustered Microcysts Detected on Breast US in Asymptomatic Women)

  • 김현진;이진화;박영미;임경재
    • 대한영상의학회지
    • /
    • 제84권3호
    • /
    • pp.676-685
    • /
    • 2023
  • 목적 본 연구는 무증상 여성의 유방 초음파에서 발견된 군집 미세낭종의 발생률, 임상적 결과 및 영상 소견을 알아보고, 적절한 조치 가이드라인을 제시하고자 한다. 대상과 방법 2014년 8월부터 2019년 12월까지 무증상 여성에서 시행한 유방 초음파에서 발견된 군집 미세낭종 병변에 대해 분석하였다. 최종 진단은 병리학적 결과 및 12개월 이상의 추적관찰로 하였다. 결과 100명의 환자에서 117개 병변이 후향적으로 연구되었으며, 군집 미세낭종의 발생률은 1.5%였다. 총 117개의 병변 중, 3개(2.6%)는 악성, 2개(1.7%)는 고위험 병변, 112개(95.7%)는 양성이었다. 악성 병변 중 2개는 관상피내암이었고, 1개는 침윤성 유관암이었다. 이중, 유방 촬영술에서 의심스러운 미세석회화 또는 초음파에서 내부 혈류를 보인 2개의 병변은 category 4로 분류되었다. 나머지는 12개월 뒤 시행한 초음파에서 echo pattern의 변화를 보인 위 음성의 증례였다. 결론 무증상 여성에서 시행한 유방 초음파에서 군집 미세낭종의 유병률은 1.5%였으며, 악성률은 2.6%였다. 군집 미세낭종의 악성률과 양성 및 악성 영상 소견을 아는 것은 영상의학과 의사들이 병변을 분류하고 적절한 조치를 권유하는 데 도움이 될 것이다.

자기공명분석기를 이용한 통증관리 (Clinical Study of Acute and Chronic Pain by the Application of Magnetic Resonance Analyser $I_{TM}$)

  • 박욱;진희철;조명현;윤석준;이진승;이정석;최석환;김성열
    • The Korean Journal of Pain
    • /
    • 제6권2호
    • /
    • pp.192-198
    • /
    • 1993
  • In 1984, a magnetic resonance spectrometer(magnetic resonance analyser, MRA $I_{TM}$) was developed by Sigrid Lipsett and Ronald J. Weinstock in the USA, Biomedical applications of the spectrometer have been examined by Dr. Hoang Van Duc(pathologist, USC), and Nakamura, et al(Japan). From their theoretical views, the biophysical functions of this machine are to analyse and synthesize a healthy tissue and organ resonance pattern, and to detect and correct an abnormal tissue and organ resonance pattern. All of the above functions are based on Quantum physics. The healthy tissue and organ resonance patterns are predetermined as standard magnetic resonance patterns by digitizing values based on peak resonance emissions(response levels or high pitched echo-sounds amplified via human body). In clinical practice, a counter or neutralizing resonance pattern calculated by the spectrometer can correct a phase-shifted resonance pattern(response levels or low pitched echo-sounds) of a diseased tissue and organ. By administering the counter resonance pattern into the site of pain and trigger point, it is possible to readjust the phase-shifted resonance pattern and then to alleviate pain through regulation of the neurotransmitter function of the nervous system. For assessing clinical effectiveness of pain relief with MRA $I_{TM}$ this study was designed to estimate pain intensity by the patient's subjective verbal rating scale(VRS such as graded to no pain, mild, moderate and severe) before application of it, to evaluate an amount of pain relief as applied the spectrometer by the patients subjective pain relief scale(visual analogue scale, VAS, 0~100%), and then to observe a continuation of pain relief following its application for managing acute and chronic pain in the 102 patients during an 8 months period beginning March, 1993. An application time of the spectrometer ranged from 15 to 30 minutes daily in each patient at or near the site of pain and trigger point when the patient wanted to be treated. The subjects consisted of 54 males and 48 females, with the age distribution between 23~40 years in 29 cases, 41~60 years in 48 cases and 61~76 years in 25 cases respectively(Table 1). The kinds of diagnosis and the main site of pain, the duration of pain before the application, and the frequency of it's application were recorded on the Table 2, 3 and 4. A distinction between acute and chronic pain was defined according to both of the pain intervals lasting within and over 3 months. The results of application of the spectrometer were noted as follows; In 51 cases of acute pain before the application, the pain intensities were rated mild in 10 cases, moderate in 15 cases and severe in 26 cases. The amounts of pain relief were noted as between 30~50% in 9 cases, 51~70% in 13 cases and 71~95% in 29 cases. The continuation of pain relief appeared between 6~24 hours in two cases, 2~5 days in 10 cases, 6~14 days in 4 cases, 15 days in one case, and completely relived of pain in 34 cases(Table 5~7). In 51 cases of chronic pain before the application, the pain intensities were rated mild in 12 cases, moderate in l8 cases and severe in 21 cases. The amounts of pain relief were noted as between 0~50% in 10 cases, 51~70% in 27 cases and 71~90% in 14 cases. The continuation of pain relief appeared to have no effect in two cases. The level of effective duration was between 6~12 hours in two cases, 2~5 days in 11 cases, 6~14 days in 14 cases, 15~60 days in 9 cases and in 13 cases the patient was completely relieved of pain(Table 5~7). There were no complications in the patients except a mild reddening and tingling sensation of skin while applying the spectrometer. Total amounts of pain relief in all of the subjects were accounted as poor and fair in 19(18.6%) cases, good in 40(39.2%) cases and excellent in 43(42.2%) cases. The clinical effectiveness of MRA $I_{TM}$ showed variable distributions from no improvements to complete relief of pain by the patient's assessment. In conclusion, we suggest that MRA $I_{TM}$ may be successful in immediate and continued pain relief but still requires several treatments for continued relief and may be gradually effective in pain relief while being applied repeatedly.

  • PDF

관상동맥질환 여성의 성기능에 관한 연구 (A Study on Sexual Function of Women with Coronary Artery Disease)

  • 김춘심;소향숙
    • 성인간호학회지
    • /
    • 제12권1호
    • /
    • pp.99-111
    • /
    • 2000
  • The purpose of this study was to identify risk factors related to sexual function of women with coronary artery disease, and to determine the predictors of sexual function. The study design, a descriptive correlational study, was done through structural questionnaire and interview. A total of 50 subjects from C University Hospital at Kwang-ju city who have undergone coronary angiography at department of cardiology were observed and interviewed from Feb. 22, 1999 to March. 23, 1999. The number of affected vessels, the level of total serum cholesterol, and the ejection fraction of 2-D echo cardiography were analyzed to evaluate the severity of coronary artery disease. And also type A behavior pattern, health behavior, Brief Index of Sexual Functioning for Women (BISF-W) were measured. The data obtained were analyzed using percentage, mean and standard deviation, t-test, ANOVA, Pearson's correlation coefficient, and stepwise multiple regression analysis via SPSS PC+. The results of this study were as follows: 1. The mean age of the subjects were 58.1 and 72.0% of those have been married over 30 years. Seventy two percentage were unemployed and monthly family income of 56.6% was less than 1,000,000 won (approximately $ 840). Eighty percent were in their postmenopausal state, and the frequency of sexual intercourse of 84.0% were two to three times per month. 2. The scores of type A behavior pattern were from 16 to 38(mean 24.94) and health behavior ranged from 21 to 43(mean 31.2). Abstinence from smoking, alcohol, and caffeine were best compliant factors and weight control and exercise were least abided ones. The result of 2D-ECHO EF showed that the half of the subjects were abnormal, and 24% had more than 240mg/dl of total serum cholesterol. The coronary angiography showed that 64% of the subjects had more than one affected vessels. 3. The predictors to explain the factor score of 'orgasm' were number of health examination, the pre- or post-menopausal state, protestant, number of coronary vessel affected, level of serum total cholesterol, and comorbid group of hypertension and diabetes, and it's total variance accounted for 52.4%. The predictors to explain the factor score of 'sexual activity' were comorbid group of hypertension and diabetes and type A behavior pattern, which accounted for 22.4% of total variance. The predictors to explain the factor score of 'sexual satisfaction' were type A behavior pattern, no religion, exercise, level of serum total cholesterol, and pre or post menopausal state, which accounted for 52.1%. The predictors to explain the factor score of 'sexual desire' were the period of marriage, type A behavior, employment or unemployment, and weight control, which accounted for 43.2%. The predictors to explain the factor score of 'external force of sexual functioning' were physical overload and exercise, which accounted for 41.1%. The predictors to explain the factor score of 'sexual activity' were family monthly income, catholics, and exercise, and which accounted for 35.4%. Above results lead us to some consensus that sexual function of women with coronary artery disease is related to various factors including vasogenic factors such as total serum cholesterol level, number of coronary vessel affected, an endocrinal factor such as menopausal state, and type A behavior pattern as a sociopshychological factor. And also health behaviors such as fitness care, overwork, weight control, and emotional tension are contributed to sexual function.

  • PDF

다중대역 SweepSAR 운용 모드의 시스템 성능 분석 (System Performance Analysis for Multi-Band SweepSAR Operating Mode)

  • 윤성식;이재욱;이택경;유상범;이현철;강은수;이상규
    • 한국전자파학회논문지
    • /
    • 제28권3호
    • /
    • pp.186-194
    • /
    • 2017
  • 본 논문에서는 고해상도 광역관측을 위한 위성 영상레이다(Synthetic Aperture Radar)의 시스템 주요 성능을 분석하였다. 배열 급전을 이용하는 반사판 안테나의 패턴을 활용하였으며, 기존의 광역관측 모드인 ScanSAR 모드와 SweepSAR 모드에 대해서 비교 분석하였다. SweepSAR 모드는 넓은 범위에 빔을 송신하고, SCORE(SCan On REceive)를 기반으로 순차적으로 빔포밍을 통해 반향신호를 수신하는 고해상도 광역관측 모드이다. 본 논문에서는 SweepSAR 모드로 동작하는 위성의 동작원리 및 특징을 분석하고, 시스템 성능 파라미터를 시뮬레이션 해석하였다. 또한, 영상의 활용도를 증대시키기 위해서 다중 주파수 대역(C-band, X-band)에 대하여 성능 분석을 수행하였다.

경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성 (Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy)

  • 임정환;송준혁;신규만;김성학
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

초점과 관련된 의문문 억양 패턴 실험 (Pitch Patterns of Interrogative Sentences in relation to the Focus)

  • 김미란;신동현;최재웅;김기호
    • 음성과학
    • /
    • 제7권4호
    • /
    • pp.203-217
    • /
    • 2000
  • In spoken language, the characteristics of prosodic realization are related to the meaning of utterance. The pitch pattern of an interrogative sentence which differs from that of declarative sentences can be considered in this respect.. If we consider the question-answer pair, we can find that the most important variation comes from the intended meaning of asking. In this paper, we experiment with four kinds of interrogative sentences and show that the difference in pitch patterns of interrogative sentences can be explained in relation to the focus phenomena that is, the differences of the boundary tones in interrogative sentences are due to the differences in the prosodic domain of focus. For a relevant explanation with the focus phenomena, we divided focus into the categories: emphatic focus, which plays a role in delivering the speaker's intended meaning for the sentence interpretation, and informational focus, delivers the central intended meaning of the utterance. The results can be summarized in three points. First, High boundary tone delivers the meaning of asking. Second, the realization of different boundary tones that are found in wh-question and alternative question are just phonetic variations caused by focusing. Third, the high rise boundary tone in echo questions is related to the meaning of surprise or incredulity, and this relation is a consensus of existing opinion, that is, the speaker's attitude of surprise can raise the pitch range. From these results we can distinguish between boundary type and phonetic variation, and we can also give appropriate meaning to the different boundary tones in interrogative sentences that have been regarded as merely a part of sentence type.

  • PDF

근거리 WLAN을 위한 광대역 마이크로스트립 패치 안테나 설계 (Design of Compact Microstrip Patch Antenna for Short Distance WLAN)

  • 최용석
    • 한국ITS학회 논문지
    • /
    • 제13권1호
    • /
    • pp.67-74
    • /
    • 2014
  • 본 논문에서는 차세대 WLAN 시스템을 위한 다중대역 마이크로스트립 패치 안테나를 설계하였다. 기존의 WLAN 시스템에서는 UWB용 안테나를 병행으로 사용하였으며, 안테나 구조에 따라 각각 다른 부분에서 복사가 일어나기 때문에 분산 특성으로 인한 불안정한 임펄스 응답 특성을 갖는 단점이 있다. 이런 점을 보완하기 위해 WLAN 대역에 적합한 복사 패턴을 갖는 UWB 안테나가 개발되었으나 임피던스 매칭이 좋지 않고 반향이 심한 문제점이 있다. 그러므로 본 논문에서는 안테나 설계 시 다양한 임피던스를 쉽게 구현할 수 있고, 설계 시 사용할 수 있는 파라미터를 더 많이 도출하여 최적의 성능을 나타낼 수 있도록 CPW 급전을 이용한 마이크로스트립 패치 안테나를 설계하였다.

Evaluation of hyoid bone movements in subjects with open bite: a study with real-time balanced turbo field echo cine-magnetic resonance imaging

  • Karacay, Seniz;Gokce, Sila;Yildirim, Ersin
    • 대한치과교정학회지
    • /
    • 제42권6호
    • /
    • pp.318-328
    • /
    • 2012
  • Objective: To assess the position and movements of the hyoid bone during deglutition in patients with open bite. Methods: Thirty-six subjects were divided into 2 groups according to the presence of anterior open bite. The open bite group (OBG) and control group each comprised 18 patients with a mean overbite of $-4.9{\pm}1.9$ mm and $1.9{\pm}0.7$ mm. The position of the hyoid bone during the 4 stages of deglutition was evaluated by measuring vertical and horizontal movement of the bone. Results: Interactions of group and stage showed no significant effect on the measurements (p > 0.05). However, when group and stage were evaluated individually, they showed significant effects on the measurements (p < 0.001). In OBG, the hyoid bone was more inferiorly and posteriorly positioned, and this position continued during the deglutition stages. Conclusions: The hyoid bone reaches the maximum anterior position at the oral stage and maximum superior position at the pharyngeal stage during deglutition. Open bite does not change the displacement pattern of the bone during deglutition. The hyoid bone is positioned more inferiorly and posteriorly in patients with open bite because of released tension on the suprahyoid muscles.

표면 SH파의 음압 통과율과 에코 안정성에 관한 실험적 검증 (Experimental Verification on the Stability and Sound Pressure Transmission Coefficient of Surface SH-Wave)

  • 이명호
    • 한국공작기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.23-30
    • /
    • 2003
  • It is very important to detect and evaluate the surface or subsurface flaws because of their influences on mechanical properties of materials. Rayleigh wave and creeping wave are commonly used for the detection of surface and subsurface flaws. These techniques, however, have following problems. Each amplitudes are remarkably affected by the surface condition and evaluation of echo pattern is usually difficult because shear wave mode propagate in the material at the same time. On the other hand, surface SH-wave which is horizontally polarized shear wave traveling along near surface layer is an attractive technique for the surface or subsurface material characterization and this technique is useful to solve the problems mentioned above. In this paper, The stability and transmission coefficient of SH waves through a viscous fluid layer is theoretically studied and simulated. Its results agreed well with the theoretical expectation for the experimental verification. These experimental results show that viscosity of couplants, thickness of couplant and surface roughness are closely related to transfer efficiency in surface SH angle beam method.